• Title/Summary/Keyword: correlated noise

Search Result 259, Processing Time 0.026 seconds

Design of a Cascade Adaptive Filter for the Performance sn Detection of Segment (ST세그먼트 검출성능향상을 종속 적응필터의 세계)

  • 박광리;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.517-524
    • /
    • 1995
  • This paper is a study on the design of the cascade adaptive filter (CAF) for baseline wandering elimination in order to enhance the performance of the detection of ST segments in ECG. The CAF using Least Mean Square (LMS) algorithm consists of two filters. The primary adaptive filter which has the cutoff frequency of 0.3Hz eliminates the baseline wandering in raw ECG The secondary adaptive filter removes the remnant baseline wandering which is not eliminated by the primary adaptive filter. The performance of the CAF was compared with the standard filter, the recursive filter, and the adaptive impulse correlated filter (AICF). As a result, the CAF showed a lower signal distortion than the standard filter and the AICF. Also, the CAF showed a better perf'ormance in noise elimination than the standard filter and the recursive filter. In conclusion, considering the characteristics of the noise elimination and the signal distortion, the CAF shows a better performance in the removal of the baseline wandering than the other three Otters and suggests the high performance in the detection of ST segment.

  • PDF

The Micro Pirani Gauge with Low Noise CDS-CTIA for In-Situ Vacuum Monitoring

  • Kim, Gyungtae;Seok, Changho;Kim, Taehyun;Park, Jae Hong;Kim, Heeyeoun;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.733-740
    • /
    • 2014
  • A resistive micro Pirani gauge using amorphous silicon (a-Si) thin membrane is proposed. The proposed Pirani gauge can be easily integrated with the other process-compatible membrane-type sensors, and can be applicable for in-situ vacuum monitoring inside the vacuum package without an additional process. The vacuum level is measured by the resistance changes of the membrane using the low noise correlated double sampling (CDS) capacitive trans-impedance amplifier (CTIA). The measured vacuum range of the Pirani gauge is 0.1 to 10 Torr. The sensitivity and non-linearity are measured to be 78 mV / Torr and 0.5% in the pressure range of 0.1 to 10 Torr. The output noise level is measured to be $268{\mu}V_{rms}$ in 0.5 Hz to 50 Hz, which is 41.2% smaller than conventional CTIA.

Finite Element Analysis of Engine Cylinder Block and Main Bore for Reliable Design (신뢰성 설계를 위한 엔진 실린더 블록과 메인 보어의 유한요소해석)

  • Yang Chulho;Han Moonsik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.39-48
    • /
    • 2005
  • Finite element analyses have been performed for the purpose of obtaining the robust and reliable design of engine cylinder block. Fatigue under high cycle operating loads is a primary concern and is evaluated by a probabilistic method. The robust and reliable design by a probabilistic method can provide satisfactory design conditions for the performance of the system under the influence of noise factors. Therefore, the design by this method will be desensitized to the uncontrollable noise factors. The simple methodology evaluates the distortion of main bore is proposed for the purpose of maintaining a well-controlled clearance between the crankshaft and main bores. The proposed methodology has proven a capability of predicting the distortion of the main bore under assembly, thermal, and firing loads. The calculated results are correlated well with the experimental ones.

Gaussian noise addition approaches for ensemble optimal interpolation implementation in a distributed hydrological model

  • Manoj Khaniya;Yasuto Tachikawa;Kodai Yamamoto;Takahiro Sayama;Sunmin Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.25-25
    • /
    • 2023
  • The ensemble optimal interpolation (EnOI) scheme is a sub-optimal alternative to the ensemble Kalman filter (EnKF) with a reduced computational demand making it potentially more suitable for operational applications. Since only one model is integrated forward instead of an ensemble of model realizations, online estimation of the background error covariance matrix is not possible in the EnOI scheme. In this study, we investigate two Gaussian noise based ensemble generation strategies to produce dynamic covariance matrices for assimilation of water level observations into a distributed hydrological model. In the first approach, spatially correlated noise, sampled from a normal distribution with a fixed fractional error parameter (which controls its standard deviation), is added to the model forecast state vector to prepare the ensembles. In the second method, we use an adaptive error estimation technique based on the innovation diagnostics to estimate this error parameter within the assimilation framework. The results from a real and a set of synthetic experiments indicate that the EnOI scheme can provide better results when an optimal EnKF is not identified, but performs worse than the ensemble filter when the true error characteristics are known. Furthermore, while the adaptive approach is able to reduce the sensitivity to the fractional error parameter affecting the first (non-adaptive) approach, results are usually worse at ungauged locations with the former.

  • PDF

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

Multiband Enhancement for DEMON Processing Algorithms (대역 분할 처리를 통한 데몬 처리 성능 향상 기법)

  • Cheong, Myoung Jun;Hwang, Soo Bok;Lee, Seung Woo;Kim, Jin Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.138-146
    • /
    • 2013
  • Passive sonars employ DEMON (Detection of Envelope Modulation on Noise) processing to extract propeller information from the radiated noise of underwater targets. Conventional DEMON processing improves SNR(Signal to Noise Ratio) characteristic by Welch method. The conventional Welch method overlaps several different time domain DEMON outputs to reduce the variance. However, the conventional methods have high computational complexity to get high SNR with correlated acoustic signals. In this paper, we propose new DEMON processing method that divides acoustic signal into several frequency bands before DEMON processing and averages each DEMON outputs. Therefore, the proposed method gathers independent acoustic signal faster than conventional method with low computational complexity. We prove the performance of the proposed method with mathematical analysis and computer simulations.

Image Denoising for Metal MRI Exploiting Sparsity and Low Rank Priors

  • Choi, Sangcheon;Park, Jun-Sik;Kim, Hahnsung;Park, Jaeseok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.215-223
    • /
    • 2016
  • Purpose: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called "Slice Encoding for Metal Artifact Correction (SEMAC)" is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. Materials and Methods: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, $l_1$ minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. Results: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. Conclusion: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.

Comparative analysis of noise from three Falcon 9 launches (Falcon 9 로켓 3회 발사 소음의 비교 분석)

  • Mathews, Logan T.;Gee, Kent L.;Hart, Grant W.;Rasband, Reese D.;Novakovich, Daniel J.;Irarrazabal, Francisco I.;Vaughn, Aaron B.;Nelson, Pauline
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.322-330
    • /
    • 2020
  • This study investigates the far-field noise from three Falcon 9 vehicle launches from Vandenberg Air Force Base, CA, USA, as measured from the same location within the nearby community of Lompoc. The overall sound pressure levels for the three launches are shown to be similar, but some differences in the early launch period are thought to be weather-related. The peak directivity angle in overall level is approximately 65 deg, which is consistent with horizontally-fired, static rocket data. For the third launch, waveforms and spectra are analyzed for different events during the launch sequence. The measured spectral bandwidth decreases with time, but spectral levels remain above the ambient noise throughout the main-engine firing. Additionally, late-launch phenomena observed in the data appear to be correlated with main-engine cutoff and second-stage engine start.

A Study on SNR Estimation of Continuous Speech Signal (연속음성신호의 SNR 추정기법에 관한 연구)

  • Song, Young-Hwan;Park, Hyung-Woo;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.383-391
    • /
    • 2009
  • In speech signal processing, speech signal corrupted by noise should be enhanced to improve quality. Usually noise estimation methods need flexibility for variable environment. Noise profile is renewed on silence region to avoid effects of speech properties. So we have to preprocess finding voice region before noise estimation. However, if received signal does not have silence region, we cannot apply that method. In this paper, we proposed SNR estimation method for continuous speech signal. The waveform which is stationary region of voiced speech is very correlated by pitch period. So we can estimate the SNR by correlation of near waveform after dividing a frame for each pitch. For unvoiced speech signal, vocal track characteristic is reflected by noise, so we can estimate SNR by using spectral distance between spectrum of received signal and estimated vocal track. Lastly, energy of speech signal is mostly distributed on voiced region, so we can estimate SNR by the ratio of voiced region energy to unvoiced.

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF