• Title/Summary/Keyword: correction parameter

Search Result 299, Processing Time 0.025 seconds

The Signal-to-Noise Ratio Enhancement of the Satellite Electro-Optical Imager using Noise Analysis Methods (영상센서신호의 잡음분석을 이용한 위성용 전자광학탑재체의 신호대잡음비 개선 방법)

  • Park, Jong-Euk;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.159-169
    • /
    • 2017
  • The Satellite Electro-Optic Payload System needsspecial requirements with the conditions of limited power consumption and the space environment of solar radiation. The acquired image quality should be mainly depend on the GSD (Ground Sampled Distance), SNR (Signal to Noise Ratio), and MTF (Modulation Transfer Function). On the well-manufactured sensor level, the thermal noise is removed on ASP (Analog Signal Processing) using the CDS (Corrective Double Sampling); the noise signal from the image sensor can be reduced from the offset signals based on the pre-pixels and the dark-pixels. The non-uniformity shall be corrected with gain, offset, and correction parameter of the image sensor pixel characteristic on the sensor control system. This paper describes the SNR enhancement method of the satellite EOS payload using the mentioned noise remove processes on the system design and operation, which is verified by tests and simulations.

A New Architecture of CMOS Current-Mode Analog-to-Digital Converter Using a 1.5-Bit Bit Cell (1.5-비트 비트 셀을 이용한 새로운 구조의 CMOS 전류모드 아날로그-디지털 변환기)

  • 최경진;이해길;나유찬;신홍규
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.53-60
    • /
    • 1999
  • In this paper, it is proposed to a new architecture of CMOS IADC(Current-Mode Analog-to-Digital Converter) using 1.5-bit bit cell of which consists a CSH(Current-Mode Sample-and-Hold) and CCMP(Current-Mode Comparator). In order to guarantee the entire linearity of IADC, the CSH is designed to cancel CFT(Clock Feedthrough) whose resolution is to meet at the least 9-bit which is placed in the front-end of each bit cell. In the proposed IADC, digital correction logic is simplified and power consumption is reduced because bit cell of each stage needs two latch CCMP. Also, it is available for a mixed-mode integrated circuit because all of block is designed with only MOS transistor. With the HYUNDAI 0.8㎛ CMOS parameter, the HSPICE simulation results show that the proposed IADC can be operated at 20Ms/s with SNR of 43 dB with which is satisfied 7-bit resolution for input signal at 100 ㎑, and its power consumption is 27㎽.

  • PDF

Influence of boundary conditions on the bending and free vibration behavior of FGM sandwich plates using a four-unknown refined integral plate theory

  • Rahmani, Mohammed Cherif;Kaci, Abdelhakim;Bousahla, Abdelmoumen Anis;Bourada, Fouad;Tounsi, Abdeldjebbar;Bedia, E.A. Adda;Mahmoud, S.R.;Benrahou, Kouider Halim;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • v.25 no.3
    • /
    • pp.225-244
    • /
    • 2020
  • The influence of boundary conditions on the bending and free vibration behavior of functionally graded sandwich plates resting on a two-parameter elastic foundation is examined using an original novel high order shear theory. The Hamilton's principle is used herein to derive the equations of motion. The number of unknowns and governing equations of the present theory is reduced, and hence makes it simple to use. This theory includes indeterminate integral variables and contains only four unknowns in which any shear correction factor not used, with even less than the conventional theory of first shear strain (FSDT). Unlike any other theory, the number of unknown functions involved in displacement field is only four, as against five, six or more in the case of other shear deformation theories. Galerkin's approach is utilized for FGM sandwich plates with six different boundary conditions. The accuracy of the proposed solution is checked by comparing it with other closed form solutions available in the literature.

Accuracy Simulation Technology for Machine Control Systems (기계장비 제어특성 시뮬레이션 플랫폼 기술)

  • Song, Chang-Kyu;Kim, Byung-Sub;Ro, Seung-Kook;Lee, Sung-Cheul;Min, Byung-Kwon;Jeong, Young-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.292-300
    • /
    • 2011
  • Control systems in machinery equipment provide correction signals to motion units in order to reduce or cancel out the mismatches between sensor feedback signals and command or desired values. In this paper, we introduce a simulator for control characteristics of machinery equipment. The purpose of the simulator development is to provide mechanical system designers with the ability to estimate how much dynamic performance can be achieved from their design parameters and selected devices at the designing phase. The simulator has a database for commercial parts, so that the designers can choose appropriate components for servo controllers, motors, motor drives, and guide ways, etc. and then tune governing parameters such as controller gains and friction coefficients. The simulator simulates the closed-loop control system which is built and parameter-tuned by the designer and shows dynamic responses of the control system. The simulator treats the moving table as a 6 degrees-of-freedom rigid body and considers the motion guide blocks stiffness, damping and their locations as well as sensor locations. The simulator has been under development for one and a half years and has a few years to go before the public release. The primary achievements and features will be presented in this paper.

Research on Speed Estimation Method of Induction Motor based on Improved Fuzzy Kalman Filtering

  • Chen, Dezhi;Bai, Baodong;Du, Ning;Li, Baopeng;Wang, Jiayin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.272-275
    • /
    • 2014
  • An improved fuzzy Kalman filtering speed estimation scheme was proposed by means of measuring stator side voltage and current value based on vector control state equation of induction motor. The designed fuzzy adaptive controller conducted recursive online correction of measurement noise covariance matrix by monitoring the ratio of theory residuals and actual residuals to make it approach real noise level gradually, allowing the filter to perform optimal estimation to improve estimation accuracy of EKF. Meanwhile, co-simulation scheme based on MATLAB and Ansoft was proposed in order to improve simulation accuracy. Field-circuit coupling problems of induction motor under the action of vector control were solved and the parameter optimization accuracy was improved dramatically. The simulation and experimental results show that this algorithm has a strong ability to inhibit the random measurement noise. It is able to estimate motor speed accurately, and has superior static and dynamic characteristics.

Study on Optimization of Fatigue Damage Calculation Process Using Spectrum (스펙트럼을 이용한 피로손상도 계산과정 최적화 연구)

  • Kim, Sang Woo;Lee, Seung Jae;Choi, Sol Mi
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.151-157
    • /
    • 2018
  • Offshore structures are exposed to low- and high-frequency responses due to environmental loads, and fatigue damage models are used to calculate the fatigue damage from these. In this study, we tried to optimize the main parameters used in fatigue damage calculation to derive a new fatigue damage model. A total of 162 bi-modal spectra using the elliptic equation were defined to describe the response of offshore structures. To calculate the fatigue damage from the spectra, time series were generated from the spectra using the inverse Fourier transform, and the rain-flow counting method was applied. The considered optimization variables were the size of the frequency increments, ratio of the time increment, and number of repetitions of the time series. In order to obtain optimized values, the fatigue damage was calculated using the parameter values proposed in previous work, and the fatigue damage was calculated by increasing or decreasing the proposed values. The results were compared, and the error rate was checked. Based on the test results, new values were found for the size of the frequency increment and number of time series iterations. As a validation, the fatigue damage of an actual tension spectrum found using the new proposed values and fatigue damage found using the previously proposed method were compared. In conclusion, we propose a new optimized calculation process that is faster and more accurate than the existed method.

Estimation of Flood Discharge Based on Observation Data Considering the Hydrological Characteristics of the Han Stream Basin in Jeju Island (한천유역의 수문학적 특성을 고려한 관측자료 기반 홍수량 산정)

  • Yang, Sung-Kee;Kim, Min-Chul;Kang, Bo-Seong;Kim, Yong-Seok;Kang, Myung-Soo
    • Journal of Environmental Science International
    • /
    • v.26 no.12
    • /
    • pp.1321-1331
    • /
    • 2017
  • This study reviewed the applicability of the existing flood discharge calculation method on Jeju Island Han Stream and compared this method with observation results by improving the mediating variables for the Han Stream. The results were as follows. First, when the rain-discharge status of the Han Stream was analyzed using the flood discharge calculation method of the existing design (2012), the result was smaller than the observed flood discharge and the flood hydrograph differed. The result of the flood discharge calculation corrected for the curve number based on the terrain gradient showed an improvement of 1.47 - 6.47% from the existing flood discharge, and flood discharge was improved by 4.39 - 16.67% after applying the new reached time. In addition, the sub-basin was set separately to calculate the flood discharge, which yielded an improvement of 9.92 - 32.96% from the existing method. In particular, the steepness and rainfall-discharge characteristics of Han Stream were considered in the reaching time, and the sub-basin was separated to calculate the flood discharge, which resulted in an error rate of -8.77 to 8.71%, showing a large improvement of 7.31 - 28.79% from the existing method. The flood hydrograph also showed a similar tendency.

A Characteristic Analysis of Single-Power-Stage High Frequency Resonant AC-DC Converter with High Power Factor (고역률 단일 전력단 고주파 공진 AC-DC 컨버터의 특성해석)

  • 남승식;원재선;황계호;오경섭;박재욱;김동희;오승훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.372-380
    • /
    • 2004
  • This paper proposes a single-power-stage high frequency resonant AC-DC converter with high power factor using ZVS(Zero Voltage Switching), and integrates a conventional converter with two stage into single stage converter. Input power factor is possible to be improved as a high power factor because inductor for power factor correction(PFC) is connected in input and converter is operated in discontinued current mode(DCM) with constant duty cycle and variable switching frequency. The conventional converter with two stage need to add a switch in order to control a power factor, but single stage converter have a advantage that system is simple and cost is down, confidence is improved, etc. This paper described a operation principle and characteristic analysis for single stage AC-DC converter with high power factor and have evaluated characteristic values by using normalized parameter. We make a experimental equipment using MOSFET as a switching device on the basis of characteristic values obtained from characteristic evaluations and we conform a rightfulness of theoretical analysis by comparing theoretical waveforms and experimental waveforms.

UDRE Monitoring Analysis of Korean Satellite Navigation System (한국형 위성항법시스템의 UDRE 모니터링 분석)

  • Park, Jong-Geun;Ahn, Jongsun;Heo, Moon-Beom;Joo, Jung Min;Lee, Kihoon;Sung, Sangkyung;Lee, Young Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.125-132
    • /
    • 2015
  • This paper is about analysis of UDRE monitoring method for Korean Satellite navigation system, which is the correction parameter of satellite measurements. New receiver clock bias and tropospheric delay error estimation method to make pseudo-range residual for UDRE monitoring is proposed. Saastamoinen model and Neill mapping function are used for estimate the tropospheric delay and EKF is used for estimgate the receiver clock bias. Through the satellite measurements and regional weather data received directly from the domestic is using for UDRE monitoring analysis, more suitable UDRE monitoring threshold can be deducted and it is expected to be utilized for fault detection technique of Korean Satellite Navigation System.

Analysis of Relationship between Mixed Venous PO2 and Status of Cardiac Performance with Hemodynamic Values after Correction of Cyanotic Congenital Heart Disease (청색심기형 교정술후 혼합정맥혈 산소분압과 심근상태 및 혈류역학치와의 상관관계 분석)

  • An, Jae-Ho;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.212-219
    • /
    • 1989
  • We utilized pulmonary artery pressure monitoring system in risky patients for preventing the postoperative pulmonary hypertensive crisis and for sampling the mixed venous blood. And this mixed venous blood oxygen saturation [MVSO2] or partial pressure [MVPO2]tells us many meaningful patients state. We selected 59 cyanotic congenital heart diseased patients, who were operated in our hospital from Nov. 1987 to Oct. 1988, in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital, who had pulmonary artery pressure monitoring catheter and who made us know their mixed venous oxygen condition. We found that there was no close relationship between MVPO2 and Cardiac Index [C.I.] during early postoperative period, but on the first and second day after operation the correlation coefficient was increased as r=0.35[p=0.008], r=0.78[p=0.0001]. So we concluded that the correlation between MVPO2 and C.I. was more reliable with time going as hemodynamic stabilization. And we experienced no survivors whose MVPO2 was under 20 torr, but that was not the only factor for death. From these results, we conclude that we can consider the MVPO2 [or MVSO2] representing C.I. after stabilized postoperative condition of the open heart surgery patients, but during early postoperative period, in addition to this MVPO2, we should do also apply other parameter such as urine output, arterial blood pressure, left atrial pressure and pulmonary arterial pressure for exact estimation of the patients status.

  • PDF