• 제목/요약/키워드: correction coefficient

검색결과 451건 처리시간 0.024초

관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석 (The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy)

  • 김병태;궁성수;범희승;정준기;박영배;이명철;이영우;고창순
    • 대한핵의학회지
    • /
    • 제21권2호
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

RCP 기후변화 시나리오에 따른 임하댐 유역의 미래 수문순환 전망 (Assessment of Climate Change Impact on Imha-Dam Watershed Hydrologic Cycle under RCP Scenarios)

  • 장선숙;안소라;조형경;김성준
    • 한국지리정보학회지
    • /
    • 제18권1호
    • /
    • pp.156-169
    • /
    • 2015
  • 본 연구는 SWAT(Soil and Water Assessment Tool) 모형을 이용하여 임하댐 유역($1,355.5km^2$)을 대상으로 RCP(AR5) 기후변화 시나리오에 따른 미래 수문순환 영향을 평가하였다. 3지점의 실측된 유출량을 활용하여 모형의 보정(2002~2007년) 및 검증(2008~2013년)을 실시하였다. 검 보정 결과 결정계수($R^2$)는 0.70~0.85로, Nash-Sutcliffe 모형 효율(NSE)은 0.67~0.82로 분석되어 신뢰성 있는 유출량 모의 결과를 나타내었다. 기후변화 시나리오는 기상청에서 제공하는 HadGEM3-RA 모형의 RCP 4.5 및 8.5 시나리오를 수집하여, 과거 34년(1980-2013, baseline period)의 기상자료를 기준으로 편이보정(Bias Correction)하여 SWAT모형에 적용하였다. 기후변화 분석 결과 강수량과 평균기온이 10.8%, $4.9^{\circ}C$ 증가하였으며, 강수량과 기온의 증가로 증발산 11.2%, 토양수분 1.9%, 지표유출 10.0%, 중간유출 12.1%, 회귀유출 18.2%이 각각 증가함에 따라 총 하천유출량이 11.2% 증가하였다.

GMS-5 IR1 밝기온도와 AWS 강우량의 관계성: 1998년 8월 중서부지역 집중호우 사례 (The Relationship between GMS-5 IR1 Brightness Temperature and AWS Rainfall: A heavy rain event over the mid-western part of Korea for August 5-6, 1998)

  • 권태영
    • 대한원격탐사학회지
    • /
    • 제17권1호
    • /
    • pp.15-31
    • /
    • 2001
  • 한반도 중서부 지역의 1998년 8월 5~6일 집중호우 사례에 대하여 GMS-5 IR1 밝기온도(CTT: 구름꼭대기 온도)와 AWS 지점 강우량 사이의 관계성을 조사하였다. 이 연구에서 AWS 시간 강우량일나 반시간 누적 강우량 보다 15분 누적 강우량을 이용하였을 때 연구지역의 강우강도와 강우영역이 중서부 지역 집중호우의 시간적 변화를 보다 자세히 묘사하고 있음을 발견하였다. 강우영역과 강우강도의 시계열 자료에서 일관되게 낮은 강우영역(20~25%)과 강한 강우강도(6~9mm/15 min)를 보여주는 8월 6일 0030-0430 LST 기간을 집중호우 기간으로 선택하였다. 그리고 이 집중호우 기간에 대하여 AWS 15분 강우량과 지상관측지점에 대응되는 CTT를 비교하였다. 위 비교에서 CTT와 AWS 강우량의 상용대수 값 사이의 상관계수는 -0.3으로 낮게 나타났으며, 강우가 관측된 AWS의 대부분이 분포하고 있는 CTT가 -5$0^{\circ}C$ 이하에서 강우확률은 약 30%에 불과했다. 그러나 위성영상의 위치 보정을 위하여 영상을 남쪽으로 2~3 격자 그리고 서쪽으로 3 격자 이동시켰을 때 CTT와 AWS 강우량의 상용대수 값 사이의 상관계수는 통계학적으로 의미있는 -0.46으로 나타났다. 그리고 강우가 관측된 AWS도 대부분이 보다 낮은 CTT 영역(-58$^{\circ}C$ 이하)에서 발견되었다. 그러나 이 영역에서의 강우확률은 원래 영상의 값과 비교할 때 큰 변화가 없었다. 심지어 일부 구간에서 CTT의 변화를 고려할 때도 강우확률은 CTT가 -58$^{\circ}C$ 이하에서 50~55%로 나타났다.

광섬유 사냑 간섭형 센서에 기반한 링형 탐촉자의 수중 음향 민감도 해석 (Acoustic Sensitivity Analysis of a Ring-type Probe Based on a Fiber-optic Sagnac Interferometric Sensor)

  • 이연우;권휴상;권일범
    • 한국광학회지
    • /
    • 제31권1호
    • /
    • pp.13-19
    • /
    • 2020
  • 광섬유 사냑 간섭형 센서를 이용해 수중 음향을 측정하기 위하여 링형 탐촉자를 적용하는 경우 민감도를 이론과 실험을 통하여 조사한다. 링형 탐촉자는 단일 모드 광섬유를 지름 5 cm의 링형으로 감아서 접착제로 패키징하였다. 링형 탐촉자는 감지 광섬유의 길이를 46.84 m로 하여 제작한 A형 탐촉자와 감지 광섬유의 길이를 112.22 m로 한 B형 탐촉자를 준비하였다. 수중 음향 시험은 상용 음향 발생기와 1 m 떨어진 거리에서 링형 탐촉자를 사용하여 50, 70, 90 kHz의 주파수에 대하여 20~100 Pa의 음향 압력 범위에서 음향 민감도를 조사하는 실험을 수행하였다. 실험 결과, 링형 탐촉자는 주파수에 대하여 다른 민감도를 나타내었으며, 이론과 비교하기 위하여 평균값을 구하였다. 세 주파수에 대한 평균 민감도는 A 탐촉자와 B 탐촉자에 대하여 각각 25.48 × 10-5, 60.79 × 10-5 rad/Pa으로 측정되었으며, 이로부터 영률 보정 계수 c값을 0.35로 결정할 수 있었다.

급성 중독환자에서 삼투압 계산식으로 추정된 에탄올 농도의 유효성 검증 (Discrepancies and Validation of Ethanol Level Determination with Osmolar Gap Formula in Patients with Suspected Acute Poisoning)

  • 정해원;이미진;조재완;안재윤;김창호
    • 대한임상독성학회지
    • /
    • 제17권2호
    • /
    • pp.47-57
    • /
    • 2019
  • Purpose: Osmolar gap (OG) has been used for decades to screen for toxic alcohol levels. However, its reliability may vary due to several reasons. We validated the estimated ethanol concentration formula for patients with suspected poisoning and who visited the emergency department. We examined discrepancies in the ethanol level and patient characteristics by applying this formula when it was used to screen for intoxication due to toxic levels of alcohol. Methods: We retrospectively reviewed 153 emergency department cases to determine the measured levels of toxic ethanol ingestion and we calculated alcohol ingestion using a formula based on serum osmolality. Those patients who were subjected to simultaneous measurements of osmolality, sodium, urea, glucose, and ethanol were included in this study. Patients with exposure to other toxic alcohols (methanol, ethylene glycol, or isopropanol) or poisons that affect osmolality were excluded. OG (the measured-calculated serum osmolality) was used to determine the calculated ethanol concentration. Results: Among the 153 included cases, 114 had normal OGs (OG≤14 mOsm/kg), and 39 cases had elevated OGs (OG>14). The mean difference between the measured and estimated (calculated ethanol using OG) ethanol concentration was -9.8 mg/dL. The 95% limits of agreement were -121.1 and 101.5 mg/dL, and the correlation coefficient R was 0.7037. For the four subgroups stratified by comorbidities and poisoning, the correlation coefficients R were 0.692, 0.588, 0.835, and 0.412, respectively, and the mean differences in measurement between the measured and calculated ethanol levels were -2.4 mg/dL, -48.8 mg/dL, 9.4 mg/dL, and -4.7 mg/dL, respectively. The equation plots had wide limits of agreement. Conclusion: We found that there were some discrepancies between OGs and the calculated ethanol concentrations. Addition of a correction factor for unmeasured osmoles to the equation of the calculated serum osmolality would help mitigate these discrepancies.

합성개구레이더 인공위성 영상을 활용한 중소규모 하천에서의 유량 추정 (Estimation of stream flow discharge using the satellite synthetic aperture radar images at the mid to small size streams)

  • 서민지;김동균;;차준호
    • 한국수자원학회논문집
    • /
    • 제51권12호
    • /
    • pp.1181-1194
    • /
    • 2018
  • 본 연구에서는 2015년에서 2017년 사이에 유럽항공우주국 Sentinel-1 위성이 촬영한 Synthetic Aperture Radar (SAR) 영상을 활용하여 한강 유역 내 하천의 유량을 추정하는 모형을 개발하였다. 한강 유역 내 15개 중소규모 하천을 연구지역으로 선정하였으며 SAR 인공위성 영상 자료와 수위 및 유량관측소에서 산정한 유량 자료를 모형 구축을 위하여 사용하였다. 우선, 오류 보정을 위해 다양한 전처리 과정을 거친 12장의 SAR 영상을 히스토그램 매칭 기법을 적용하여 이미지의 밝기 분포를 동일하게 만들었다. 이후 임계치 분류방식을 사용하여 추출된 하천 수체의 면적과 지상 관측유량자료와의 관계식을 도출하여 유량추정모형을 구축하였다. 그 결과, 1개소를 제외한 14개 관측소에서 인공위성에서 추출한 하천 면적을 입력 자료로 하는 멱함수 형태의 유량추정모형을 구축할 수 있었다. 14개 관측소의 최소, 평균, 최대 결정 계수($R^2$)는 0.3, 0.8, 0.99로 나타났다.

영상을 활용한 시설물 안전점검 작업 효율성 향상 방안 연구 (A Study on Improving the Efficiency of Facility Safety Inspection Work Using Images)

  • 전경식;김진태;이병길
    • 한국측량학회지
    • /
    • 제39권3호
    • /
    • pp.179-186
    • /
    • 2021
  • 일반적으로 구조물에서의 손상을 조사하고 손상 크기를 측정하는 일상안전점검 활동은 지금까지 점검인력에 의한 육안점검에 크게 의존하고 있다. 이러한 인력에 의한 시설물의 상태 및 성능점검은 조사자의 주관적 판단에 의존하는 경우가 많기 때문에 측정결과의 일관성과 반복성이 저하될 수 있다. 특히 접근이 어려운 곳에 위치한 손상은 육안에 의한 경험에 주로 의존하고 있으며, 필요한 경우에 사다리를 이용하는 안전하지 못한 방법이 주로 사용되고 있다. 이에 본 연구에서는 안전점검 조사자 간 편차를 줄여 객관성을 확보하고, 작업자의 안전성을 강화할 수 있는 영상 활용 기법을 제안하고자 하였다. 본 연구에서는 촬영대상과의 거리와 촬영각도에 따른 영상의 변화를 보정하는 방법으로 평면사영변환을 적용하였다. 실험대상에 대한 변환된 영상에서 손상 크기를 분석한 결과 손상 크기 측정의 정확도는 목표 수준인 5.0mm와 0.005m2를 만족시킬 수 있는 것으로 확인되었다. 제안된 영상 보정 기법을 적용한 현장검증시험 결과, 구조물에 발생된 균열의 길이의 변동계수는 5.4~7.0%에서 0.072~0.12%로 감소하였고, 손상 면적의 변동계수는 10.9%에서 1.6%로 줄어들었고, 측정의 정확도가 향상되는 것을 확인하였다. 그러므로 안전점검 활동에서의 영상 활용 기법에 대한 본 연구를 통해 손상 크기 측정 정확도 향상 및 안전점검 보고서와 외관조사망도에 대한 신뢰도 향상을 기대할 수 있을 것으로 판단된다.

기상모델자료와 기계학습을 이용한 GK-2A/AMI Hourly AOD 산출물의 결측화소 복원 (Spatial Gap-filling of GK-2A/AMI Hourly AOD Products Using Meteorological Data and Machine Learning)

  • 윤유정;강종구;김근아;박강현;최소연;이양원
    • 대한원격탐사학회지
    • /
    • 제38권5_3호
    • /
    • pp.953-966
    • /
    • 2022
  • 에어로솔(aerosol)은 대기 질을 악화시키는 등 인체 건강에 악영향을 끼치므로 에어로솔의 분포 및 특성에 대한 정량적인 관측이 필수적이다. 최근 전 지구 규모에서의 주기적이고 정량적인 정보 획득 수단으로 위성관측 Aerosol Optical Depth (AOD) 영상이 다양한 연구에 활용되지만 광학센서 기반의 위성 AOD 영상은 구름 등의 조건을 가진 일부 지역에서 결측을 가진다. 이에 본 연구는 위성자료의 결측복원을 위하여 격자형 기상자료와 지리적 요소를 입력변수로 하여 Random Forest (RF) 기반 gap-filling 모델을 생성한 이후, gap-free GK-2A/AMI AOD hourly 영상을 산출하였다. 모델의 정확도는 -0.002의 Mean Bias Error (MBE), 0.145의 Root Mean Square Error (RMSE)로, 원자료의 목표 정확도보다 높으며 상관계수 0.714로 복원 대상이 대기변수인 점을 감안하면 상관계수 측면에서도 충분한 설명력을 갖춘 모델이다. 정지궤도 위성의 높은 시간 해상도는 일변화 관측에 적합하며 대기보정을 위한 입력, 지상 미세먼지 농도 추정, 소규모 화재 또는 오염원 분석 등 타 연구를 위한 자료 활용 측면에서 중요하다.

비산먼지 자동 저감시스템을 이용한 콘크리트 제조업 환경 유지관리 기술 (Environmental Maintenance Technology for Concrete Manufacturing Industry by Using an Automatic Fugitive Dust Reduction System)

  • 조현우;정윤석;류득현;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권4호
    • /
    • pp.70-77
    • /
    • 2023
  • 미세먼지는 생태학적으로 심각한 문제를 발생시키는 원인이고, 건설현장에서 발생되는 비산먼지는 국내 미세먼지의 주요 발생 원인이다. 그러나 콘크리트 제조업 현장을 포함한 건설 현장에서는 비산먼지 발생단계에서 측정은 거의 이루어지지 않고 있으며, 수동적인 제거방안들이 대부분인 실정이다. 따라서, 본 연구에서는 콘크리트 제조업에서 골재 하역시 발생하는 비산먼지를 발생단계에서 관리하기 적합한 비산먼지 측정 방법을 선정하고, 자동 비산먼지 저감시스템을 골재 하역장에 적용하여 저감시스템 작동 여부에 따른 비산먼지 저감량을 분석하는 것을 목적으로 하였다. 결과적으로, 베타선흡수법과 광산란법의 비교측정을 통하여 광산란법의 신뢰성을 확보하였고, 광산란법 보정계수를 산출하여 콘크리트 제조업 현장 비산먼지 질량농도 측정값에 적용하였다. 또한, 자동 비산먼지 저감시스템 작동 여부에 따른 비산먼지 저감률을 도출하였다.

복부 파형강판을 사용한 PSC 복합 교량의 비틀림 해석모델의 제안 및 변수해석 (A Development of Torsional Analysis Model and Parametric Study for PSC Box Girder Bridge with Corrugated Steel Web)

  • 이한구;김광수
    • 대한토목학회논문집
    • /
    • 제28권2A호
    • /
    • pp.281-288
    • /
    • 2008
  • 콘크리트와 강재의 특성을 살린 복합구조 교량에 있어서 새로운 구조 형식인 복부 파형강판 PSC 박스거더 교량은 시공성 및 경제적인 측면에서 우수한 장점이 있다. 그러나 이와 관련된 기존 연구는 전단 좌굴에 대한 복부 파형강판의 거동 및 접합부의 형상 개발과 관련하여 한정된 측면이 있으며, 교량 자체로서의 비틀림 거동에 대한 연구는 다소 부족한 실정으로 합리적인 비틀림 해석모델의 개발과 거동 예측에 대한 연구가 필요하다고 판단된다. 본 연구에서는 복부 파형강판 PSC 박스거더 교량에 대하여, 공간트러스 모델을 이용한 Rausch의 제안식과 RC 요소의 연화효과가 고려된 평형 방정식, 적합 조건식을 활용하고 복부 파형강판 구조 형태에 의하여 추가적으로 고려해야 할 구성 방정식과 모델, 제안식 등을 적용한 비틀림 해석모델을 제시하고 기존에 수행된 부재 실험결과와의 비교를 통하여 해석모델의 합리성을 검토하였다. 또한 복부 파형강판 PSC 박스의 비틀림 거동에 영향을 미치는 프리스트레싱 힘과 콘크리트 압축강도를 변수로 한 해석을 진행하였으며, 제안된 비틀림 해석모델을 이용하여 복부 파형 강판과 프리스트레스 된 콘크리트 부재의 단면 형상비(H/B)에 따른 해석을 수행하여 보다 합리적인 비틀림 정수와 이와 관련한 수정식을 제안하였다.