• Title/Summary/Keyword: cornea thickness

Search Result 42, Processing Time 0.02 seconds

Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea (한국인 20세부터 24세까지 각막 두께와 안압의 분석)

  • Douk Hoon Kim;Kishor Sapkota
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam (Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석)

  • Kim, Douk-Hoon;Bae, Han-Yong
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth of 20 to 24 Years old population in Korea (한국인 20세부터 24세까지의 중심 각막 두께, 앞방 부피, 앞방 깊이에 대한 상관관계 분석)

  • Sang Yeul Park;Douk Hoon Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.12 no.1
    • /
    • pp.1654-1659
    • /
    • 2024
  • Purpose: The aim of this study was to determine Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth in Koreans aged 20 to 24 years using the Pentacam tool. Methods: The subjects of this study were 53 Korean adults with healthy eyes. The central corneal thickness(CCT), anterior chamber volume(ACV), and anterior chamber depth(ACD) was measured with Pentacam device. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 22.0±2.01 years. The mean +/- central corneal thickness of the right eye and left eye were 546.66±32.221mmg and 545.70±32.759mm, respectively. Also The mean central cornea thickness was 546.19 um in the whole sample. The mean anterior chamber volume the right eye and left eye was 181.66±33.738 mm3 and 180.12±30.84 mm3, respectively. The mean anterior chamber depth was 3.158±0.257 mm and 3.122±0.233 mm in right eye and left eye, respectively. There was a statistically significant difference between anterior camber volume and anterior chamber depth(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and anterior chamber volume. Also there was no statistically significant difference between central cornea thickness and anterior chamber depth. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adolescents.

An Excel Program for Dk Calculation of Contact Lens (엑셀 프로그램을 이용한 콘택트렌즈의 Dk 결정)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2011
  • Purpose: The review article was written to establish an excel program that could calculate minimal Dk of contact lens without $O^2$ deficiency and actual $O^2$ concentration on cornea when contact lens were being fitted by changing lens-related factors. Methods: An excel program was formulated to calculate the thickness of post-lens lacrimal layer, Dk of contact lens and $O^2$ concentration on cornea. Results: With the excel program established, minimal $O^2$ concentration needed on cornea could be calculated when the thickness of post-lens lacrimal layer was changed by varying lens-related factors. A different route in the excel program was needed to choose based on the shape of lacrimal layer. The thickness of lacrimal layer was determined by the shape of meniscus made of tear between lens edge and cornea with flat fit. Thus, the $O^2$ concentration showing negative number in calculation decreased on peripheral cornea with flatter fitting and actual $O^2$ concentration would be zero on cornea. With tight fitting, the thickness of post-lens lacrimal layer is much thicker than lens itself thus negative number in calculation by the excel program is shown indicating zero oxygen on cornea. It can cause $O^2$ deficiency regardless of Dk of contact lens. Conclusions: The calculation of thickness of post-lens lacrimal layer and $O^2$ concentration on cornea by the established excel program is suggested to avoid $O^2$ deficiency when fitting state is varied by changing lens-related factors.

Oxygen Diffusion According to the Fitting Conditions of Contact Lens (콘택트렌즈의 피팅조건에 따른 산소확산)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • Purpose: This review article was written to investigate how the various factors, such as lacrimal thickness, CL's thickness and Dk, affects the influx of $O_2$ diffusion into the cornea. Methods: A mathematical model was proposed to analyze the oxygen diffusion reaching the cornea through the tear layers and contact lens based on Fick's law and the principle of continuity of the diffusion flux through the each layers. Results: The model predicts how the parameters such as the thickness of tear layer on the cornea, both the Dk and thickness of contact lenses etc., affect the oxygen tension at cornea and oxygen flux entering the cornea. Conclusions: It is found that either too flat or too tightly fitted contact lenses can cause the oxygen deficiency at/inside the periphery of the cornea because of the reduction of oxygen flux resulted from too thickened tear layer.

  • PDF

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.

Model on the Oxygen Transmission of Contact Lenses according to the Fitting (콘택트렌즈의 산소투과에 대한 피팅의 영향)

  • Kim, Daesoo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 2003
  • A mathematical model was proposed to analyze the oxygen diffusion reaching the cornea through the tear layers and contact lens based on Fick's law and the principle of continuity of the diffusion flux through the each layers. The model predicts how the parameters such as the thickness of tear layer on the cornea, both the Dk and thickness of contact lenses etc., affect the oxygen tension at cornea and oxygen flux entering the cornea. It is found that either too flat or too tightly fitted contact lenses can cause the oxygen deficiency inside the periphery of the cornea because of the reduction of oxygen flux resulted from too thickened tear layer.

  • PDF

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

Age and Sex Related Changes in Corneal Thickness and Anterior Corneal Curvature in Korean Young Population with Orbscan II Topography System

  • Lee, Dong-Hee;Kim, Douk-Hoon;Park, Seung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • This study investigated, using the Orbscan II topography system, the influence of age and sex related changes on the corneal thickness and anterior corneal curvature, more specifically the fine structure of the cornea, in a Korean young population. The Orbscan II topography system is a computer-assisted slit-beam scanning technology that can map the anterior section of the cornea. The mean central corneal thickness of all subjects was $547.532{\pm}44.529\;{\mu}m$. There was no statistical difference (p>0.5) in the mean central corneal thickness between males and females. Sex and age related changes in the mean central corneal thickness had no specific statistical difference (P>0.5). There was a negative correlation between the anterior corneal curvature and the central corneal thickness in all subjects, except for the twenty year olds. However, the thickness relationship between the mean central corneal and the eight paracentral corneal thicknesses had strong statistical differences in all subjects. Also age and sex related changes in the central corneal thickness and the anterior corneal curvature in all subjects had no statistically significant difference, except from 20-26 years old (p>0.05). This information could be a suitable reference basis for future studies in the young population of Asia and for the development of examination tools for corneal refractive surgery.