• 제목/요약/키워드: core protection

검색결과 402건 처리시간 0.031초

Concept Development of Core Protection Calculator with Trip Avoidance Function using Systems Engineering

  • Nascimento, Thiago;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.47-58
    • /
    • 2020
  • Most of the reactor trips in Korean NPPs related to core protection systems were caused not because of proximity of boiling crisis and, consequently, a damage in the core, but due to particular miscalculations or component failures related to the core protection system. The most common core protection system applied in Korean NPPs is the Core Protection Calculator System (CPCS), which is installed in OPR1000 and APR1400 plants. It generates a trip signal to scram the reactor in case of low Departure from Nucleate Boiling Ratio (DNBR) or high Local Power Density (LPD). However, is a reactor trip necessary to protect the core? Or could a fast power reduction be enough to recover the DNBR/LPD without a scram? In order to analyze the online calculation of DNBR/LPD, and the use of fast power reduction as trip avoidance methodology, a concept of CPCS with fast power reduction function was developed in Matlab® Simulink using systems engineering approach. The system was validated with maximum of 0.2% deviation from the reference and the dynamic deviation was maximum of 12.65% for DNBR and 6.72% for LPD during a transient of 16,000 seconds.

변압기 보호용 수정 전류차동 계전방식 (A Modified Current Differential Relay for Transformer Protection)

  • 강용철;김은수;원성호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

Modified-Current-Differential Relay for Transformer Protection

  • Kang Yong-Cheol;Jin En-Shu;Won Sung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.1-8
    • /
    • 2005
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a significant exciting current, which can cause malfunction of a current-differential relay. This paper proposes a modified-current-differential relay for transformer protection. The relay calculates the core-loss current from the induced voltage and the core-loss resistance as well as the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. A comparative study of the conventional differential relay with harmonic blocking is presented. The proposed relay not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the relay speed.

잔류자속을 고려한 변압기 보호용 수정 전류차동 계전방식 (A Modified Current Differential Relaying Algorithm for Transformer Protection Considered by a Remanent Flux)

  • 강용철;김은숙;원성호;임의재;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.262-265
    • /
    • 2003
  • During magnetic inrush or over-excitation saturation of the core in a transformer draws a large exciting current. This can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. In order to cope with the remanent flux at the beginning. the start of saturation of the core is detected and the core flux at the instant is estimated by inserting the differential current into a magnetization curve. Then, this core flux value can be used to calculate the core flux. The proposed relay calculates the core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss current and the magnetizing current from the conventional differential current. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

  • PDF

스캔 설계된 AES 코아의 효과적인 비밀 키 보호 기술 (An Efficient Secrete Key Protection Technique of Scan-designed AES Core)

  • 송재훈;정태진;정혜란;김화영;박성주
    • 대한전자공학회논문지SD
    • /
    • 제47권2호
    • /
    • pp.77-86
    • /
    • 2010
  • 본 논문은 Advanced Encryption Standard(AES) 암호화 코아가 내장된 System-on-a-Chip(SoC)의 스캔 기반 사이드 채널 공격에 의해 발생될 수 있는 비밀 키 정보 누출 방지를 위한 효과적인 스캔 설계 기술을 제안한다. 본 논문에서 제안하는 시큐어 스캔 설계 기술은 IEEE 1149.1의 명령어 방식을 사용하여 거짓 키를 이용한 테스트를 진행한다. 또한 어플리케이션에 최적화 되어있는 암호화 IP 코아를 수정하지 않고 적용을 할 수 있다. SoC상의 IEEE 1149.1 제어기 표준을 유지하며 기존 방식에 비해 낮은 면적오버헤드 및 전력 소모량을 갖는 기술을 제안한다.

지적 기반 산림생태네트워크 보호구역 설정방안 (A Method for Zoning the Parcel-based Protecting Area of the Ecological Network in Forest)

  • 장래익;장갑수;정옥식;나정화
    • 한국환경복원기술학회지
    • /
    • 제12권6호
    • /
    • pp.131-142
    • /
    • 2009
  • The purpose of this study is to detect the protection area around the Geum-buk and Geum-nam Mountains for making a sustainable ecological network. The protection area in the Geum-buk and Geum-nam Mountains was analyzed by using spatial data and a field survey for landscape conservation purposes. A survey scope was fixed using digital elevation model, and the protection area was finally determined based on the parcel map called as the Korea Land Information System (KLIS). Here we have several conclusions in this study. First, spatial data used in this study were a map of ecological and natural degree (MEND), forest distribution map, elevation map, slope map, and several maps for the protection area assigned by laws regarding to the natural resources. Second, we used 4 alternatives to determine the best choice for showing the ecological network in the study area. One alternative (alt. 3) of 4 ones was finally chosen as the best condition for making the ecological network. The condition in elevation and slope was a little modified to a lower level in alt, 3. The result derived from alt, 3 reflected the continuity and connectivity in the ecological network and we estimate that the protection area can protect the core area using the buffer zone around the ecological network. Finally the parcel-based protection area in the Geum-buk and Geum-nam Mountains had $493.92km^2$ of the core area, and $233.99km^2$ of the buffer zone, which means the parcel-based protection area increased by $97.76km^2$ in the core area, but decreased by $76.61km^2$ as of in the topographical map.

OPΔT 및 OTΔT트립설정치의 생산방법 (OPΔT and OTΔT Trip Setpoint Generation Methodology)

  • Ki In Han
    • Nuclear Engineering and Technology
    • /
    • 제16권2호
    • /
    • pp.106-115
    • /
    • 1984
  • 원자로 안전한계 설정의 근본목적은 핵연료 및 원자료 계통의 건전성을 보장할 수 있도록 원자로 운전조건을 제한하자는 데 있다. 원자로 보호계통은 원자로 운전변수들이 트립설정치에 도달하게 되면 원자로를 긴급정지시켜 운전조건이 안전한계를 초과하지 못하도록 한다. 따라서 이들 트립설정치의 생산을 위해서는 계산과 측정오차를 충분히 고려해 주어야 한다. 본 기술보고서에서는 웨스팅하우스 원자로 보호계통 트립설정치의 생산에 따른 기본원리와 노심 안전한계의 개발방법 및 트립설정치의 생산절차를 검토하였다. 웨스팅하우스 보호계통 트립설정치의 생산원리는 노심의 안전한계를 계산하고 측정 및 계산에 따른 불확실성을 충분히 고려하여 보수적인 트립설정치를 생산함으로써 핵연료의 용융과 DNB가 발생하지 않도록 하자는 데 있다.

  • PDF

잔류자속에 무관한 변압기 보호용 수정전류차동 계전기 (Modified Current Differential Relay for Transformer Protection Unaffected by Remanent flux)

  • 강용철;김은숙
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.500-506
    • /
    • 2004
  • This paper proposes a modified current differential relay for transformer protection unaffected by the remanent flux. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. To cope with the remanent flux, before saturation, the relay calculates the core-loss current and uses it to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the actual core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation because the exciting current was successfully compensated. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. The relay discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

급성기 뇌졸중 환자의 기능상태 측정을 위한 ICF 핵심지표 (ICF Core Sets for Measuring Functional Status of Acute Stroke Patients)

  • 박미진;강지연
    • 근관절건강학회지
    • /
    • 제19권2호
    • /
    • pp.107-119
    • /
    • 2012
  • Purpose: This study was conducted to extract international classification of functioning, disability, and health (ICF) core sets for measuring functional status in acute stroke patients, and to evaluate clinical applicability of the core sets. Methods: A set of 22 ICF items on functional status in acute stroke patients were extracted from the Korean general ICF core sets and ICF core sets for stroke patients. The extracted ICF functional items were assessed at the time of admission and discharge among 100 stroke patients who were admitted in a university hospital. Results: Comparing to functional status at admission of acute stroke patients, the overall functional status at discharge was improved. However, functions on defecation, skin protection, and relationship with immediate family at the time of discharge were not significantly changed. Conclusion: The set of ICF functional items identified in this study may be reliable and valid to assess acute stoke patients' body functions, activities and participation and environmental factors in the holistic and comprehensive nursing context. Nursing interventions on bowel elimination and skin protection for acute stroke patients need to be developed.