• Title/Summary/Keyword: core loss

Search Result 1,001, Processing Time 0.035 seconds

A Study on Core shape optimization to Improve The Efficiency of High Frequency Transformer for Inverter (인버터용 고주파 변압기의 효율 향상을 위한 코어 형상 최적화 설계에 대한 연구)

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.29-35
    • /
    • 2014
  • The purpose of high frequency transformer in the inverter is to reduce the voltage and current stresses of switch components when it operates at the large conversion ratio. But the loss of transformer is the major contributor in the efficiency of inverter. This paper presents the method of core design to minimize the loss of transformer. The total loss of transformer is minimized by adjusting the effective cross-sectional areas of core. The component ratio of losses are compared by using the finite-element analysis.

Fabrication and Characterization of Thermal Expanded Core Fiber using the Flame Brushing Method (프레임 브러싱 방법을 이용한 열확산 코어 광섬유 제작 및 특성)

  • Kim, Jun-Hyong;Yang, Hoe-Young;Lee, Sang-Pil;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1077-1081
    • /
    • 2007
  • Thermal expanded core (TEC) fiber can reduce, being advantaged from thermal diffusion technology, connection loss by expanding the tolerance in relation to axial offset and gap when making optical connection having mode field diameter (MFD) of optical fiber expanded locally. In this paper, TEC fiber fabrication system based on the frame brushing techniques using twin-torch tip was designed and developed in order to maintain a stable thermal diffusion and single-mode when manufacturing TEC fiber. We were able to obtain that varied kinds of TEC fibers of which MFD could have been extended between $20\;{\mu}m$ and $40\;{\mu}m$ by TEC fiber fabrication system. In addition, the characteristic of connection loss was measured by alignment two TEC fibers of which MFD was $30\;{\mu}m$.

The Study on The Magnetic Properties of Amorphous Fe-B-Si-Ge Ribbons (Fe-B-Si-Ge 비정질 리본의 자기적 특성 연구)

  • 민복기
    • Electrical & Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.113-118
    • /
    • 1997
  • For the amorphous F $e_{78}$ $B_{13}$S $i_{9-x}$G $e_{x}$ alloy, thermal analysis and measurements of the magnetic properties were carried out. As the content of Ge increased, the crystallization temperature was decreased and the Curie temperature was increased, and the tendencies were almost linear. The core loss of the amorphous alloy for x=1.7, field annealed at optimized condition, was 0.057 W/kg(l.0T, 60Hz), which was about 30% lower than that of no Ge added amorphous alloy (basic composition). Such a low core loss characteristics was thought to be caused by the lower coercive force and good squareness of B-H loop of the alloy.y.y.

  • PDF

A study on Loss Evaluation Technology of High Efficiency Mold Transformers using Electromagnetic Field Simulation (전자계해석을 이용한 고효율 몰드변압기 손실 평가기술 연구)

  • Chung, Sang Hoon;Lee, Kon;Choi, Myung Jun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.774-775
    • /
    • 2015
  • In this paper, a series of electromagnetic analyses carried out for a high efficiency 22.9/0.38kV mold transformer are presented. The simulations were performed in order to calculate the losses which eventually verify the performance(efficiency) of the designed product. Here, losses include core loss, stray losses of non-current carrying metallic structural parts(core plate and clamp), ohmic loss and eddy current loss of current carrying metallic parts(busbars, leads, terminals and windings). The obtained results of the simulations were compared to the test results and showed high level of accuracy. The loss evaluation technology will allow designers avoid any potential over-design or under-design of the high efficiency products, reducing the manufacture cost and development period compared to the conventional experience-based design procedures.

  • PDF

Design Solutions to Minimize Iron Gore Loss in Synchronous Reluctance Motors Using Preisach Model & FEM (프라이자흐 모델이 결합된 유한요소 해석을 이용한 동기형 릴럭턴스 전동기의 철손 최소화 회전자 구조 설계)

  • Lee, D.D.;Lee, M.M.;Sim, J.M.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.138-140
    • /
    • 2002
  • This paper deals with an automatic design procedure for the minimization of iron core loss in a synchronous reluctance motor (SynRM). The focus of this paper is the design relative to hysteresis loss on the basis of rotor shape of a SynRM in the same torque density. The coupled Finite Elements Analysis (FEA) & Preisach model have been used to evaluate the iron core loss with the rotor shape. The proposed procedure allows to define the rotor geometric dimensions starting from an existing motor or a preliminary design. The iron loss has been reduced with a rotor design variation.

  • PDF

A Tie-plate Shape Optimization of 24MVA Cast Resin Transformer for Reduction of Stray Loss (24MVA 몰드 변압기의 손실저감을 위한 Tie-Plate의 형상 최적설계 연구)

  • Kim, Yong-Bae;Shin, Pan-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.55-61
    • /
    • 2014
  • This paper presents a method to reduce the stray loss of core Tie-Plate of distribution power transformer. The method combines a 3-dimensional FEM with PSO(Particle Swarm Optimization) algorithm to determine the shape of the Tie-Plate that minimizes eddy current and flux-leakage losses. To verify the method a 24MVA distribution(cast-resin) transformer was simulated using one objective function and two design variables with some constraints. The final optimized Tie-Plate has nine($3{\times}3$) slots of 10mm width, 15mm thickness and 25mm distance. After four iterations, the Tie-Plate loss was reduced to about 21 % of the original.

Core Loss Analysis of IPM Motor Considering Magnetic Saturation and Manufacturing of Electrical Steel (전기강판의 가공 및 포화를 고려한 IPM 모터의 철손 해석)

  • Ha, Kyung-Ho;Kim, Gi-Hyun;Kim, Jae-Kwan;Lee, Sun-Kwon;Na, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.887.1_888.1
    • /
    • 2009
  • This paper proposes a core loss analysis method to obtain high accuracy prediction by using Multi-curve representing magnetic properties of a electrical steel in Finite Element Analysis (FEA). Generally, the magnetic prosperities of the electrical steel are measured by Epstein Method based on the international standards that are not good sufficient to predict motor performances. The method only aims to grade products in steel companies The magnetic properties of actual stator core is highly different to those given by steel companies due to the fact that stacking effect, shearing stress, nature anisotropy of electrical steels are not taken into account. In this paper, the magnetic properties are variously measured by three measuring devices, and then the several BH curves and BW curves obtained are used to analyze the core loss of a IPM. The BH curve in the high magnetic field are extrapolated using the mathematical formulation with the maximum saturation magnetic polarization measured

  • PDF

Core-loss Reduction on Permanent Magnet for IPMSM with Concentrated Winding (집중권을 시행한 영구자석 매입형 동기전동기의 철손 저감)

  • Lee, Hyung-Woo;Park, Chan-Bae;Lee, Byung-Song
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.2
    • /
    • pp.135-140
    • /
    • 2012
  • Interior Permanent Magnet Synchronous motors (IPMSM) with concentrated winding are superior to distributed winding in the power density point of view. But it causes huge amount of eddy current losses on the permanent magnet. This paper presents the optimal permanent magnet V-shape on the rotor of an interior permanent magnet synchronous motor to reduce the core losses and improve the performance. Each eddy current loss on permanent magnet has been investigated in detail by using FEM (Finite Element Method) instead of equivalent magnetic circuit network method in order to consider saturation and non-linear magnetic property. Simulation-based design of experiment is also applied to avoid large number of analyses according to each design parameter and consider expected interactions among parameters. Consequently, the optimal design to reduce the core loss on the permanent magnet while maintaining or improving motor performance is proposed by an optimization algorithm using regression equation derived and lastly, it is verified by FEM.

Rapidly Solidified Fe-6.5wt% Si Alloy Powders for High Frequency Use

  • Park, Seung-Dueg;Yang, Choong-Jin
    • Journal of Magnetics
    • /
    • v.2 no.1
    • /
    • pp.12-15
    • /
    • 1997
  • Fe-(3∼6.5wt%) Si alloy powders having a high magnetic induction(Bs) and a low core loss value for high frequency use were obtained by an extractive melt spinning as well as a centrifugal atomization technique. Sintered core rings made by the rapidly solidified Fe-6.5wt% Si powders exhibited the high frequency magnetic properties : megnetic induction(B8) of 1.23 T, coercivity(Hc) of 0.12 Oe, relative permeability(${\mu}$a) of 6321, and core loss(W10/50) of 1.27 W/kg from the rings of 1.1 mm thick. The magnetic induction values were found to be almost identical to those of non-oriented Fe-6.5wt% Si steel sheet and double the value of 6.5wt% Si sheet prepared by the CVD technique. The high frequency core losses(W) up to 10 kHz(W10/10k) were measured to be competitive to those of grain-oriented Fe-6.5wt% Si steel sheet.

  • PDF

A Study on the Magnetic Properties of Fe-base Amorphous Alloys in High Frequency (철계비정질합금의 고주파 자기특성 연구)

  • 송재성;김기욱;정순종
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.4
    • /
    • pp.379-384
    • /
    • 1992
  • The Fe-base amorphous ribbons with 15mm width and about 20x10S0-6Tm thickness, (FeS179-xTCrS1xT)BS116TSiS15T and (FeS181-xTMnS1xT) BS112TSiS17T (x:0-6), were prepared melt spinner. The thickness of the ribbons followed by PFC (Planar Flow Casting). The initial permeability and total core losses were measured as a function of additive elements (Cr, Mn) and annealing conditions in high frequency for the purpose of using these materials as a core of magnetic amplifier and switched mode power supplies. The initial permeabilities were enhanced and core losses were decreased by non-magnetic field annealing in proper conditions. The lowest core loss in 0.2T/10kHz was measured at 3% Cr addition amorphous ribbon, and the loss was 5.6W/kg. The permeability of the ribbon at 10kHz was about 9000.