• 제목/요약/키워드: copper loss

검색결과 301건 처리시간 0.028초

부 채널 신호에 대한 박막의 영향 (Thin Film Effects on Side Channel Signals)

  • 선용빈
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.51-56
    • /
    • 2013
  • Even if transmissions through normal channel between ubiquitous devices and terminal readers are encrypted, any extra sources of information retrieved from encrypting module can be exploited to figure out the key parameters, so called side channel attack. Since side channel attacks are based on statistical methods, making side channel signal weak or complex is the proper solution to prevent the attack. Among many countermeasures, shielding the electromagnetic signal and adding noise to the EM signal were examined by applying different thicknesses of thin films of ferroelectric (BTO) and conductors (copper and gold). As a test vehicle, chip antenna was utilized to see the change in radiation characteristics: return loss and gain. As a result, the ferroelectric BTO showed no recognizable effect on both shielding and adding noise. Cu thin film showed increasing shielding effect with thickness. Nanometer Au exhibited possibility in adding noise by widening of bandwidth and red shifting of resonating frequencies.

동기 리럭턴스 전동기의 고성능 운전을 위한 효율 최적화 제어 (Efficiency Optimization Control for High Performance Operation of Synchronous Reluctance Motor)

  • 정동화;이정철;이홍균
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.51-56
    • /
    • 2001
  • This paper is proposed an efficiency optimization control algorithm for a synchronous reluctance motor (SynRM) which minimizes the copper and iron losses. fen exists a variety of combinations of d and q-axis current which provide a specific motor torque. The objective of the efficiency optimization controller is to seek a combination of d and q-axis current components, which provides minimum losses at a certain operating point in steady state. It is shown that the current components which directly govern the torque production have been very well regulated by the efficiency optimization control scheme. The proposed algorithm allows the electromagnetic losses in variable speed and torque drives to be reduced while keeping good torque control dynamics. Simulation results are presented to show the validity of the proposed algorithm.

  • PDF

A Comparative Study of the Line Start Permanent Magnet, Skeleton Type Brushless DC, and Snail-earn Type Switched Reluctance Motor for Fans

  • Lee, Ji-Young;Lee, Geun-Ho;Hong, Jung-Pyo;Jin Hur
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.122-126
    • /
    • 2004
  • The objective of this paper is to provide a comparison between the Line Start Permanent Magnet, Skeleton type Brushless DC, and the Snail-cam type Switched Reluctance Motor. These motors are compared under the same load characteristic as the cooling fan motor of a refrigerator. The comparison consists of speed, output power, efficiency, copper loss, and cost for three different motors. For the given application, the results provide an indication of the best machine suited with respect to performance and cost.

Key Application Technologies of High Efficiency Power Quality Control Systems

  • Liu, Ding-Guo;Shuai, Zhi-Kang;Tu, Chun-Ming;Cheng, Ying;Luo, An
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.458-468
    • /
    • 2013
  • Large capacity reactive power compensation and harmonic control in the low-voltage grid of an enterprise, are important technical means to improve power quality and reduce power loss. In this paper, the principle of an efficient power quality controller is analyzed. Then, key application technologies of the HPQC which would influence the performances of the HPQC are studied. Based on an analysis of the harmonic shunt problem, a frequency dividing control strategy of the HPQC continuous subsystem is proposed. A parameter design method of the HPQC discrete subsystem and its installation method are also proposed to ensure the system compensation effect. HPQC systems have been designed for a copper foil plant. The effectiveness of this paper has been verified by the simulation and application results.

전력시설물에 대한 VE 와 LCC기법 도입에 관한 연구 (Report on VE & LCC (Value Engineering, Life Cycle Cost) Technics Introduction about the Electric Power Equipment)

  • 김상직;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.81-86
    • /
    • 2003
  • 최근 대형 전력시설물에 대한 VE 와 LCC 기법의 도입은 여러 가지 형태로 수행되고 있으며, 일반적으로 전력 시설물의 비용을 생각할 때 그 초기투자비만을 대상으로 평가하는 경향이 있으나, 시설물의 총 생애비용 (보전비, 수선비, 개선비, 운용비, 전력비등)을 동시에 고려하여야 한다. 본 연구에서는 간선설계에서 장거리 급전시 전압강하로 인한 동손비를 고려한 설계기법과 내구년한에 따른 총생애비용기법을 적용하여 타당성을 입증하였다.

  • PDF

도전손실을 저감한 용접기용 전원장치 (A Power Supply for Welding machine of Reducing Conduction Losses)

  • 라병훈;구헌회;조기연;서기영;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.192-194
    • /
    • 1998
  • This paper proposes a power supply for welding machine of reducing conduction Losses. To improve the conventional Phased-Shift FB DC-DC converter's problems that the copper loss in the high frequency transformer and conduction losses in the 1st terms bridge switch device because the leakage energy in the high frequency transformer and inducing of circulating current. This paper suggested a new topology of FB PWM DC-DC converter for welding machine to minimize a circulating current.

  • PDF

초전도변압기의 계통적용을 위한 예상 시장진입가격 추정 (Evaluate the expected price of HTS transformer for introducing into korean power system)

  • 김종율;이승렬;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.176-178
    • /
    • 2004
  • HTS (High Temperature Superconducting) Transformer has the several useful characteristics in the viewpoints of technical and economical. Especially, an HTS transformer replaces the copper wire coils in a conventional transformer with lower loss HTS wire In addition, inexpensive, environmentally benign liquid nitrogen replaces the conventional oil as the electrical insulation (dielectric) and provides the necessary cooling for the HTS transformer Therefore, the Life-cycle cost of an HTS transformer is much more attractive than conventional because it is more energy efficient, lighter in weight, smaller in size, and environmentally compliant. HTS transformer can be the best way to replace with conventional transformer in the future. In this paper, we investigate the expected price of HTS transformer to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional transformer is calculated and based on this, the expected price of HTS transformer is evaluated, which HTS transformer is competitive against conventional transformer.

  • PDF

DEVELOPMENT OF THE ALTERNATE PRESSURIZED THERMAL SHOCK RULE (10 CFR 50.61a) IN THE UNITED STATES

  • Kirk, Mark
    • Nuclear Engineering and Technology
    • /
    • 제45권3호
    • /
    • pp.277-294
    • /
    • 2013
  • In the early 1980s, attention focused on the possibility that pressurized thermal shock (PTS) events could challenge the integrity of a nuclear reactor pressure vessel (RPV) because operational experience suggested that overcooling events, while not common, did occur, and because the results of in-reactor materials surveillance programs showed that RPV steels and welds, particularly those having high copper content, experience a loss of toughness with time due to neutron irradiation embrittlement. These recognitions motivated analysis of PTS and the development of toughness limits for safe operation. It is now widely recognized that state of knowledge and data limitations from this time necessitated conservative treatment of several key parameters and models used in the probabilistic calculations that provided the technical of the PTS Rule, 10 CFR 50.61. To remove the unnecessary burden imposed by these conservatisms, and to improve the NRC's efficiency in processing exemption and license exemption requests, the NRC undertook the PTS re-evaluation project. This paper provides a synopsis of the results of that project, and the resulting Alternate PTS rule, 10 CFR 50.61a.

Virtual Signal Injected MTPA Control for DTC Five-Phase IPMSM Drives

  • Liu, Guohai;Yang, Yuqi;Chen, Qian
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.956-967
    • /
    • 2019
  • This paper introduces a virtual signal injected maximum torque per ampere (MTPA) control strategy for direct-torque-controlled five-phase interior permanent magnet synchronous motor (IPMSM) drives. The key of the proposed method is that a high frequency signal is injected virtually into the stator flux linkage. Then the responding stator current is calculated and regulated to compensate the amplitude of the flux linkage. This is done according to the relationship between the stator current and the stator flux linkage. Since the proposed method does not inject any real signals into the motor, it does not cause any of the problems associated with high-frequency signals, such as additional copper loss and extra torque ripple. Simulation and experimental results are offered to verify the effectiveness of the proposed method.

능동 자기 베어링을 위한 동기 노치필터 제어기와 스위칭 제어기의 성능 비교 연구 (Comparative Study of Performance of Switching Control and Synchronous Notch Filter Control for Active Magnetic Bearings)

  • 유승열;노명규
    • 대한기계학회논문집A
    • /
    • 제37권4호
    • /
    • pp.511-519
    • /
    • 2013
  • 능동 자기베어링의 바이어스 선형화 방법은 자기베어링의 동역학적 성능과 선형성을 확보하지만, 바이어스 전류에 의한 상시 소모전력이 발생하여 시스템의 효율이 저하된다. 반면, 스위칭 제어기는 바이어스 전류를 사용하지 않아 베어링의 소비 전력을 최소화할 수 있다. 본 논문에서는 능동 자기베어링 시스템에 적용되는 스위칭 제어기와 동기 노치필터를 포함하는 비례-미분 제어기의 성능을 비교하였다. 공정하고 객관적인 비교를 위해 기준제어기인 동기 노치필터 제어기를 합리적으로 설계하고, 스위칭 제어기가 기준제어기와 동일한 동역학 특성을 갖도록 하였다. 회전축의 굽힘 유연모드 및 센서와 증폭기의 특성을 포함하는 시스템의 동역학 모델을 수립하고 성능 비교 지표를 수립하였다. 불평형 질량에 응답 측면에서 제어기를 비교하여, 저속 영역에서 스위칭 제어기가 기준제어기 대비 10 배 이상 동손을 저감할 수 있으나, 회전축의 굽힘 유연모드와 일치하는 회전 속도 근방에서는 스위칭 제어기가 유효하지 않음을 확인하였다.