• Title/Summary/Keyword: coordinate measuring machine

Search Result 133, Processing Time 0.028 seconds

Determination of Sampling Points Based on Curvature distribution (곡률 기반의 측정점 결정 알고리즘 개발)

  • 박현풍;손석배;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.295-298
    • /
    • 2000
  • In this research, a novel sampling strategy for a CMM to inspect freeform surfaces is proposed. Unlike primitive surfaces, it is not easy to determine the number of sampling points and their locations for inspecting freeform surfaces. Since a CMM operates with slower speed in measurement than optical measuring devices, it is important to optimize the number and the locations of sampling points in the inspection process. When a complete inspection of a surface is required, it becomes more critical. Among various factors to cause shape errors of a final product, curvature characteristic is essential due to its effect such as stair-step errors in rapid prototyping and interpolation errors in NC tool paths generation. Shape errors are defined in terms of the average and standard deviation of differences between an original model and a produced part. Proposed algorithms determine the locations of sampling points by analyzing curvature distribution of a given surface. Based on the curvature distribution, a surface area is divided into several sub-areas. In each sub-area, sampling points are located as further as possible. The optimal number of sub-areas. In each sub-area, sampling points are located as further as possible. The optimal number os sub-areas is determined by estimating the average of curvatures. Finally, the proposed method is applied to several surfaces that have shape errors for verification.

  • PDF

A MEASUREMENT OF DISPLACEMENTS OF CAST FRAMEWORK BY TORCH SOLDERING AND ELECTRIC SOLDERING TECHNIQUES (화염 납착법과 전기 납착법에 의한 금합금 주조체의 변위 양상에 관한 계측학적 연구)

  • Jeon, Sang-Won;Lim, Jang-Seop;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.791-799
    • /
    • 1999
  • The purpose of this study was to investigate the displacements of cast framework by torch soldering and electric soldering techniques. Specimen had two cylinders and connecting bar that had sectioned with 0.3mm gap at mid point. 10 of total specimens were divided into two groups. In torch soldered group, soldering investment block was made and conventional torch solder-ing procedure was carried out. In electric soldered group, electric soldering was carried out on the master cast without soldering investment block by using electric soldering machine(Dentapunkt DP 7, Kulzer, Germany) After soldering procedure, three dimensional coordinates of two centroids of each cylinder were measured by three dimensional coordinate measuring machine. The intercentroidal displacement and global displacement were calculated and then, these values were compared and evaluated. The results were obtained as follows: 1. Intercentroidal distances of specimens decreased after both soldering procedures, and the decrease in intercentroidal distance was greater for torch soldered group than for electric soldered group 2. Global displacements of torch soldered group were greater than those of electric soldered group.

  • PDF

Development of the Injection Molded Ball Seat for Automobile Suspension (자동차 서스펜션용 볼 시트 사출성형품 개발)

  • Ye, Sang-Don;Min, Byeong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.4
    • /
    • pp.50-56
    • /
    • 2011
  • Injection molding process is one of the popular manufacturing methods to produce plastic parts with high efficiency and low cost. Ball seat for automobile suspension is made by an injection molding process as a part to support pivot function of ball joint consisted of ball stud and housing. It is necessary for a ball seat to have a dimensional stability in the three dimensional inner area to be contacted with ball stud. In this paper, the dimensional stability of inner surface is indirectly analyzed by checking the difference of inner diameter around the circumferential direction and the thickness variation at the top part of ball seat. Measurement was performed by using the coordinate measuring machine and the fixture to hold ball seat. Optimization of injection molding processes such as injection time, cooling time and temperatures of cylinder barrel was derived to reduce the difference of inner diameter and the thickness variation at the top part of ball seat based on the Taguchi method.

A study on based shape monitoring in HERW pipe production by using structured light beam (구조화된 직선빔을 이용한 구조파 전기 저항 용접파이프의 비드 형상 측정에 관한 연구)

  • 고국원;김종형;조형석;공원일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.672-678
    • /
    • 1993
  • The bead shape in high frequency electric resistance (HER) pipe welding gives important information ons judging current welding state. In most manufacturing process, the heat input is controlled by skilled operators observing color and bead shape. We proposed the bead shape monitoring system in HERW pipe process by using structured light beam. We reconstructs 3-D shape of bead from the measured data, and compare this shape with real 3-D shape obtained by coordinate-measuring machine. This experiment results show that the proposed system can monitor the bead shape with good accuracy.

  • PDF

The performance improvement of the volumetric interferometer with multi-CCDs (다중 CCD를 이용한 부피 간섭계의 성능 개선)

  • 주지영;이혁교;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.268-271
    • /
    • 2003
  • The Volumetric Interferometer using two spherical wavefronts emitted from the ends of two single mode fibers has been suggested to measure 3-dimensional absolute coordinates. In this paper, we try to improve the performance of the volumetric interferometer using multi-CCDs. We get coordinates matching matrixes between CCDs and can obtain more information in the space with multi-CCDs. Also we find out the best arrangement of multi-CCDs by computer simulations. In the simulation we can know that it will be better to increase the distance between CCDs to improve performance. For the performance test, we do a repeatability test, a comparison test with 2-D stage and the self-calibration using artifact.

  • PDF

Error Assessment of CMM by Self-calibration Method (자가 보정 방법을 이용한 삼차원 측정기의 계통 오차 추출)

  • 유승봉;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.379-382
    • /
    • 2002
  • Among the CMM calibration techniques, the calibration with standard specimen is most accurate way to acquire the required precision. When there is no standard specimen, the calibration of CMM with itself is possible. This calibration method is called "self-calibration". In this paper, we developed self-calibration algorithm for CMM XY plane. It is possible to calculate the in-plane error and out-of-plane error of CMM with 3 different measurement of same artifact. Experimental result shows that the non-orthogonality error is dominant in in-plane error and the self-calibration result and laser interferometer measured result have almost same value.ame value.

  • PDF

Failure Behavior of Piercing Plug during Seamless Tube Manufacturing Process (심리스 튜브 제조공정 시 피어싱 플러그의 파손거동)

  • Lim, Young-Bin;Yoon, Jeong-Mo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.30 no.5
    • /
    • pp.207-214
    • /
    • 2017
  • In this study, failure behavior of piercing plug for seamless tube manufacturing process was studied. Three different kinds of passed piercing plugs (10, 90, 215 times) were prepared. The shape deformation of the passed piercing plugs was observed by 3D coordinate measuring machine, and the oxidized layer on the surface of piercing plug was observed by optical microscopy. The length reduction of piercing plug presented at 215 times passed plug. It was found that the oxidized layer consisted of outer scale, inner scale and internal oxidation layers, and the inner scale layer had vertical cracks, and interfaces had horizontal cracks. We proposed the failure mechanism of piercing plug during seamless tube manufacturing process based on the formation of vertical and horizontal crack.

Development of Multipurpose Welding Jig for Sub-Frame (서브 프레임 제작용 다목적 용접지그 개발)

  • Shin, H.G.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.131-136
    • /
    • 2011
  • In commercial vehicle, sub-frame which equipped in main frame supporting dump deck and oil tanker. This is the main structure for all equipment which including joint function. Sub-frame is made by welding process, this susceptible to deform and crack by its longitudinal size. Also various kind of sub-frame make it difficult to standardization in manufacturing process and exclusive jig is not adapted yet. Frame size is over 6~8m and weight is more than 300kg this make re-work more difficult. If manufacturing company made precise sub-frame, this is not only convenient for customers but also save the company money by reducing the working time. In this study manufacture the sub-frame be suitable for its main function and develop exclusive welding jig for obtain checking fixture function as well.

A STUDY FOR THE MEASUREMENTS OF THE RESIDUAL STRESS AND THE DISTORTIONS IN THE CERAMO-METAL BRIDGE OF Pd-Ag ALLOY (팔라듐-은 합금 도재소부전장 가공의치의 잔류응력과 변형에 관한 연구)

  • Jeon, Young-Chan;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.53-78
    • /
    • 1989
  • This study was taken to observe the changes of the residual stress in the alloy and to measure 3 dimensional distortions of the long span ceramo-metal bridge. The materials used in this study were Pors-on 4 (Pd-Ag alloy), and Ceramco and Vita VMK 68 powders. The residual stress of the alloy was measured on the six specimens (dia. 8m/m) by the X-ray diffraction stress analyzer according to the kind of ceramic powder and different measuring stages. And, for the measurement of the distortions, fifteen specimens of the anterior 8-unit ceramo-metal brige were fabricated and subjected to the 3-D coordinate measuring machine. Variables included the 2 kinds of a ceramic powder and the presence or absence of a splint bar at the cast metal framework. The measuring stages in both were after casting, after degassing and after glazing. The following conclusions were obtained : 1. The residual stress of the alloy showed increasing tendency for the tension by the ceramic fusing, but there was not significance. 2. The tendency of the distortions in the cast metal frameworks were decrease of the width, the anterior displacement and sagging. 3. The amount of the distortions at the degassing stage were greater than that at the ceramic fusing stage. 4. The splint bar was effective to control the distortion only at ceramic fusing stage. 5. The sagging distortion in the Ceramco firing were even through all measuring stages, but in the Vita firing, pronounced at degassing stage.

  • PDF

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.