• Title/Summary/Keyword: cooling temperature

Search Result 4,647, Processing Time 0.033 seconds

A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center (데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구)

  • Chang, Hyun Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System (냉방시스템의 운전조건에 따른 에너지 소비특성 연구)

  • Park, Gi-Tae;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

Prediction of Tool Life on Cooling System in Warm Forging (온간 단조에서의 냉각방법에 따른 금형 수명 예측)

  • 이현석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.67-70
    • /
    • 2000
  • The tool life is not long enough under sever forming condition in warm forging. The tool life is affected by wear heat fatigue plastic deformation and so on. Especially wear is one of the most serious factors for tool life. To increase tool life we should consider various factors like processing design die design die materials lubrication and cooling system This study design to obtain the steady state temperature of die by FEM analysis under several conditions of cooling. There are four cooling conditions in this study no cooling internal cooling external cooling and both internal and external cooling. With above obtained temperatures tool life is predicted using Archard's model that is considered softening of die. The effect of internal cooling system is better than that of externally cooled die. To predict the die life the steady state temperature is calculated by using mean temperature of die. Considering only wear the die life much longer as the cooling effect is bigger. The more accurate die life will be predicted if we consider heat crack as well as wear.

  • PDF

Comparison of Linear Channel and Baffle for Cooling Rate in Injection Mold (사출성형금형에서 직선채널과 배플의 냉각효율 비교)

  • Moon, Young-Bae;Choi, Youn-Sik;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Plastic products are producted more than 70% of total processes in the injection molding. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The time and system of cooling affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. In this study, it was made a comparative study about cooling of linear channels and baffles and observed the variation of mold temperature on the coolant's temperature. As the result, the linear channel's cooling rate had faster than baffles and as coolant's temperature was increased, difference of cooling time was increased. Result of this study will be used widely to design for cooling system of injection mold.

  • PDF

A Study of the Surface Temperature Reduction Using Pipe Cooling System in Asphalt Pavement (아스팔트 도로포장에 물순환 파이프 시스템을 이용한 표면온도저감에 관한 연구)

  • Yoon, Yong Kyu;Park, Kyung Won;Lee, Suk Keun
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.75-86
    • /
    • 2013
  • PURPOSES: The purpose of asphalt pavement reducing surface temperature by using Pipe cooling system is to make pleasant city life environment. METHODS: We considered building condition to lay the pipes under asphalt pavement and figured out that temperature reducing effect with pipe cooling system. In addition, we guessed rutting through wheel tracking test with a laid the pipes under asphalt mixture and performed fatigue cracking through a flexural fatigue test for performance evaluation of pipe cooling system. RESULTS: When pipe cooling system worked, the temperature of pavement model reduced quickly in test. The system can turn down the degree by 4 or 5 quickly as well. It didn't affect rutting to lay the pipes under the pavement, but it can get damaged to asphalt pavement in early stage by the result of performance evaluation. CONCLUSIONS: We figured out that pipe cooling system can turn down the temperature of aspalt pavement surface through tests. We suggest that pipe cooling system should be considered one of the effective way to solve urban heat island problem.

Characteristics of Cooling Temperature of Cold Water Pipes Buried in the Wall of a Small Mobile Modular House (소형 이동식 모듈주택의 벽면에 냉수배관 매설에 의한 냉방온도 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.110-117
    • /
    • 2022
  • A chiller cooler absorbs the thermal energy of water to generate cold water and supplies the generated cold water to a cold water pipe buried in the wall of a small mobile modular house to greatly increase the cooling area. An attempt was made to reduce the required cooling time significantly. A small chiller cooler suitable for the cooling load of a small mobile modular house with an area less than 3.3 m2 was employed. When cooling is done during summer using a chiller cooler installed outdoors, heat absorption energy loss occurs in the cold water pipe owing to the high temperature. To address this, a study was conducted to reduce the endothermic energy loss significantly. As the mass flow rate of the cold water flowing inside the cold water pipe increased, the temperature decrease gradient of the cold water increased. From the start of the cooling operation, the air temperature of the small mobile modular house decreased linearly in proportion to the operation time. Furthermore, the temperature of the air inside the small mobile modular house decreased in proportion to the increase in the flow of water inside the cold water pipe.

CSTC of High Strength Steel for ROT Process in Hot Strip Mills (열간압연 ROT에서 고강도강의 CSTC 개발)

  • Park, Cheol-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.191-196
    • /
    • 2008
  • This paper proposes a cooling stop temperature control(CSTC) concept which aims at obtaining the uniform temperature and quality of the material along the longitudinal and lateral direction of the strip. The CSTC is designed using the experimental CCT(Continuous Cooling Transformation), TTT(Time Temperature Transformation) curves and the temperature control model by the heat transfer governing equation, and the temperature control simulator. The cooling pattern and the rolling speed can be solved by the CSTC. It is shown through the field test of the hot strip mill of POSCO that the phase transformation ratio of the high carbon steel is considerably improved by the proposed temperature control.

An Experimental Study on Low-Temperature Behavior of Stratified Fluids in a Square Cavity with Upper Cooling Surface (상부에 냉각면이 있는 정방형내 이종유체의 저온거동에 관한 실험적 연구)

  • Lee, D.S.;Kim, B.C.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.55-62
    • /
    • 2000
  • An experimental study on the stratified fluids with water and silicon oil of same volume in the cavity with upper cooling surface was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in a square cavity. The experiments were performed with variation of initial temperature and cooling surface temperature. The temperature drop of oil was faster than that of water and freezing was initiated from the interface of oil and water and propagated downward. For the water above $4^{\circ}C$, the cooling rate was faster than that below $4^{\circ}C$ and showed almost same temperature distribution but for the water that of below $4^{\circ}C$, it showed the stable stratified temperature distribution. The lower the initial temperature and the higher the cooling surface temperature was, the longer the supercooling duration.

  • PDF

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF