• 제목/요약/키워드: cooling period

검색결과 410건 처리시간 0.032초

낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로 (Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir)

  • 박준상;임윤규;김규랑;조창범;장준영;강미선;김백조
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

그린홈 보급확대를 위한 건물용 연료전지 보조기기 국산화 기술개발 (Technology development on localization of BOP components for 1kW stationary fuel cell systems to promote green-home dissemination project)

  • 김민석;이선호;전희권;배준강
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.128.2-128.2
    • /
    • 2010
  • For stationary 1kW-class fuel cell systems to be used widely, it is essential to achieve dramatic improvements in system durability as well as cost reduction. In order to address this engineering challenge, it is important to develop innovative technologies associated with BOP components. According to this background, in 2009, the Korean Government and "Korea Institute of Energy Technology Evaluation and Planning(KETEP)" launched into the strategic development project of BOP technology for practical applications and commercializations of stationary fuel cell systems, named "Technology Development on Cost Reduction of BOP Components for 1kW Stationary Fuel Cell Systems to Promote Green-Home Dissemination Project". The objectives of this project are to develop fundamental technologies to meet these requirements, and to improve the performance and functionality of BOP components with reasonable price. The project consortium consists of Korea's leading fuel cell system manufacturers, BOP component manufacturers which technologically specialized, and several research institutions. This paper is to provide a summary of the project, as well as the achievements made through the 1st period of the project(2009~2010). Several prototypes of BOPs - Cathode air blowers, burner air blowers, preferential oxidation air blowers, fuel blowers, cooling water pumps, reformer water pumps, heat recovery pumps, mass flow meters, valves and power conditioning systems - had been developed through this project in 2010. As results of this project, it is expected that a technological breakthrough of these BOP components will result in a substantial system cost reduction.

  • PDF

Evolution and scaling of a simulated downburst-producing thunderstorm outflow

  • Oreskovic, Christopher;Savory, Eric;Porto, Juliette;Orf, Leigh G.
    • Wind and Structures
    • /
    • 제26권3호
    • /
    • pp.147-161
    • /
    • 2018
  • For wind engineering applications downbursts are, presently, almost exclusively modeled, both experimentally and numerically, as transient impinging momentum jets (IJ), even though that model contains none of the physics of real events. As a result, there is no connection between the IJ-simulated downburst wind fields and the conditions of formation of the event. The cooling source (CS) model offers a significant improvement since it incorporates the negative buoyancy forcing and baroclinic vorticity generation that occurs in nature. The present work aims at using large-scale numerical simulation of downburst-producing thunderstorms to develop a simpler model that replicates some of the key physics whilst maintaining the relative simplicity of the IJ model. Using an example of such a simulated event it is found that the non-linear scaling of the velocity field, based on the peak potential temperature (and, hence, density) perturbation forcing immediately beneath the storm cloud, produces results for the radial location of the peak radial outflow wind speeds near the ground, the magnitude of that peak and the time at which the peak occurs that match well (typically within 5%) of those produced from a simple axi-symmetric constant-density dense source simulation. The evolution of the downdraft column within the simulated thunderstorm is significantly more complex than in any axi-symmetric model, with a sequence of downdraft winds that strengthen then weaken within a much longer period (>17 minutes) of consistently downwards winds over almost all heights up to at least 2,500 m.

우울증(憂鬱症)의 임상양상(臨床樣狀) 및 생체전기자율반응에 대(對)한 임상적(臨床的) 고찰(考察) (A Clinical Study of Depression in 43 Cases)

  • 박지운;이상룡;최병만
    • 동의신경정신과학회지
    • /
    • 제12권2호
    • /
    • pp.37-51
    • /
    • 2001
  • The clinical study was carried out the 43 patients with Depression who were treated in Department of Neuropsychiatry, College of Oriental Medicine, Dae Jeon University from 22 February 2000 to 14 November 2001. The results were summarized as follows. 1. The ratio of male and female was 10:33, 60's(32.6%) was frequent, no inducing factor(38.3%) was seen in a lot of cases and many patients came to our hospital by way of west-neuropsychiatry(56.8%). 2. The period of clinical history was frequent from 3 to 10 years(23.2%), the most frequent preceding disease was cardiovascular systemic disease(18.4%). 3. The main clinical symptoms were apprehension alpitation(13.4%), anorexia(9.8%), headache nuchal region stiffness(9.8%), general body weakness(6.5%), chest discomfort(6.5%), dizziness(5.7%), febris(5.3%) and constipation(5.3%). 4. The patient's tongue aspect had pink tongue and empty fur(32.6%) and pulse type had thin and deficient pulse(39.5%). The prescription drugs were Chunggansoyo-san(30.0%), purging liver and alleviating depression to regulate qi, and Guibiondam-tang(15.8%) eliminating phlegm, cooling pericardium and warming gallbladder. 5. The curve was within normal range at Psychoneural system(81.4%), and Visceral system(90.1%). 6. The regulation was Normal(48.1%), RL(27.9%), RR(20.2%) at Psychoneural system and Normal(45.9%), RL(28.5%), RR(20.3%) at Visceral system. 7. Activity and Reactivity had much lower response at 1th, 2th, 3th, 4th, 7th SANGHAN, Polalization had much higher response at 1th, 4th, SANGHAN and much lower response at 2th, 3th, 7th SANGHAN.

  • PDF

하늘시계지수 비교 및 도시기온 상관성 연구: 강남 선정릉지역을 중심으로 (A Study on a Comparison of Sky View Factors and a Correlation with Air Temperature in the City)

  • 이채연;신이레;안승만
    • 대기
    • /
    • 제27권4호
    • /
    • pp.483-498
    • /
    • 2017
  • Sky view factor can quantify the influence of complex obstructions. This study aims to evaluate the best available SVF method that represents an urban thermal condition with land cover in complex city of Korea and also to quantify a correlation between SVF and mean air temperature; the results are as follows. First, three SVF methods comparison result shows that urban thermal study should consider forest canopy induced effects because the forest canopy test (on/off) on SVF reveals significant difference range (0.8, between maximum value and minimum value) in comparison with the range (0.1~0.3) of SVFs (Fisheye, SOLWEIG and 3DPC) difference. The significance is bigger as a forest cover proportion become larger. Second, R-square between SVF methods and urban local mean air temperature seems more reliable at night than a day. And as the value of SVF increased, it showed a positive slope in summer day and a negative slope in winter night. In the SVF calculation method, Fisheye SVF, which is the observed value, is close to the 3DPC SVF, but the grid-based SWG SVF is higher in correlation with the temperature. However, both urban climate monitoring and model/analysis study need more development because of the different between SVF and mean air temperature correlation results in the summer night period, which imply other major factors such as cooling air by the forest canopy, warming air by anthropogenic heat emitted from fuel oil combustion and so forth.

동해지역 NOAA/AVHRR 고해상도 주평균 해수면 온도의 통계적 분석 : 지역적 변동성과 엘니뇨/남방진동과의 관계성 (Statistical Analysis of NOAA/AVHRR High Resolution Weekly SST in the East Sea: Regional Variability and Relationships with ENSO)

  • 권태영;이방용;이정순
    • Ocean and Polar Research
    • /
    • 제23권4호
    • /
    • pp.361-376
    • /
    • 2001
  • The characteristics of SST variability in the East Sea are analyzed using NOAA/AVHRR weekly SST data with about $0.18^{\circ}{\times}0.18^{\circ}$ resolution ($1981{\sim}2000$) and reconstructed historical monthly SST data with $2^{\circ}{\times}2^{\circ}$ resolution $(1950{\sim}1998)$. The distinct feature of wintertime SST is high variability in the western and eastern parts of $38^{\circ}{\sim}40^{\circ}$ latitudinal band, which are the northern boundary of warm current in the East Sea during winter. However, summertime SST exhibits variability with similar magnitude in the entire region of the East Sea. The analysis of remote correlation also shows that SST in the East Sea is closely correlated with that in the region of Kuroshio in winter, but in summer is related with that in the western and eastern regions of the same latitudes. From these results it is postulated that the SST variability in the East Sea may be related with the variations of East Korean Warm Current and Tsushima Warm Current in winter, but in summer probably with the variations of atmospheric components. In the analysis of ENSO related SST anomaly, a significant negative correlation between SST anomalies in the East Sea and SST anomalies in the tropical Pacific is found in the months of August-October (ASO). The SST in the ASO period shows more significant cooling in E1 $Ni\~{n}o$ events than warming in La $Ni\~{n}a$ events. Also, the regional analysis shows by the Student's t-test that the negative SST anomalies in the E1 $Ni\~{n}o$ events are more significant in the southwestern part of the East Sea.

  • PDF

동남극 윌크스랜드 대륙대의 마이오세 중-후기 동안 생물기원 오팔 생산과 고기후 변화(IODP Exp 318 Site U1359) (Biogenic Opal Production and Paleoclimate Change in the Wilkes Land Continental Rise (East Antarctica) during the Mid-to-late Miocene (IODP Exp 318 Site U1359))

  • 송부한;김부근
    • Ocean and Polar Research
    • /
    • 제37권1호
    • /
    • pp.23-35
    • /
    • 2015
  • A 450 m-long sediment section was recovered from Hole U1359D located at the eastern levee of the Jussieau submarine channel on the Wilkes Land continental rise (East Antarctica) during IODP Expedition 318. The age model for Hole U1359D was established by paleomagnetic stratigraphy and biostratigraphy, and the ages of core-top and core-bottom were estimated to be about 5 Ma and 13 Ma, respectively. Biogenic opal content during this period varied between 3% and 60%. In the Southern Ocean, high biogenic opal content generally represents warm climate characterized by the increased light availability due to the decrease of sea-ice distribution. The surface water productivity change in terms of biogenic opal content at about 10.2 Ma in the Wilkes Land continental rise was related to the development of Northern Component Water. After about 10.2 Ma, more production of Northern Component Water in the North Atlantic caused to increase heat transport to the Southern Ocean, resulting in the enhanced diatom production. Miocene isotope events (Mi4~Mi7), which are intermittent cooling intervals during the Miocene, appeared to be correlated to the low biogenic opal contents, but further refinement was required for precise correlation. Biogenic opal content decreased abruptly during 6 Ma to 5.5 Ma, which most likely corresponds to the Messinian salinity crisis. Short-term variation of biogenic opal content was related to the extent of sea-ice distribution associated with the location of Antarctic Polar Front that was controlled by glacial-interglacial paleoclimate change, although more precise dating and correlation will be necessary. Diatom production in the Wilkes Land continental rise increased during the interglacial periods because of the reduced sea-ice distribution and the southward movement of Antarctic Polar Front.

LARGE-SCALE VERSUS EDDY EFFECTS CONTROLLING THE INTERANNUAL VARIATION OF MIXED LAYER TEMPERATURE OVER THE NINO3 REGION

  • Kim, Seung-Bum;Lee, Tong;Fukumori, Ichiro
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.21-24
    • /
    • 2006
  • Processes controlling the interannual variation of mixed layer temperature (MLT) averaged over the NINO3 domain ($150-90^{\circ}W$, $5^{\circ}N-5^{\circ}S$) are studied using an ocean data assimilation product that covers the period of 1993 to 2003. Advective tendencies are estimated here as the temperature fluxes through the domain's boundaries, with the boundary temperature referenced to the domain-averaged temperature to remove the dependence on temperature scale. The overall balance is such that surface heat flux opposes the MLT change but horizontal advection and subsurface processes assist the change. The zonal advective tendency is caused primarily by large-scale advection of warm-pool water through the western boundary of the domain. The meridional advective tendency is contributed mostly by Ekman current advecting large-scale temperature anomalies though the southern boundary of the domain. Unlike many previous studies, we explicitly evaluate the subsurface processes that consist of vertical mixing and entrainment. In particular, a rigorous method to estimate entrainment allows an exact budget closure. The vertical mixing across the mixed layer (ML) base has a contribution in phase with the MLT change. The entrainment tendency due to temporal change in ML depth is negligible comparing to other subsurface processes. The entrainment tendency by vertical advection across the ML base is dominated by large-scale changes in wind-driven upwelling and temperature of upwelling water. Tropical instability waves (TIWs) result in smaller-scale vertical advection that warms the domain during La Ni? cooling events. When the advective tendencies are evaluated by spatially averaging the conventional local advective tendencies of temperature, the apparent effects of currents with spatial scales smaller than the domain (such as TIWs) become very important as they redistribute heat within the NINO3 domain. However, such internal redistribution of heat does not represent external processes that control the domain-averaged MLT.

  • PDF

지속가능한 도시개발을 위한 LID평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가 (LIDMOD Development for Evaluating Low Impact Development and Its Applicability to Total Maximum Daily Loads)

  • 전지홍;최동혁;김태동
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.58-68
    • /
    • 2009
  • Low impact development (LID) technique is relatively new concept to reduce surface runoff and pollutant loading from land cover by attempting to match predevelopment condition with various integrated management practices (IMPs). In this study, computational model for designing and evaluating LID, named LIDMOD, was developed based on SCS-CN method and applied at Andong bus terminal to evaluate LID applicapability and design retention/detention area for volume or peak flow control. LIDMOD simulated with 21 years simulation period that yearly surface runoff by post-development without LID was significantly higher than that with LID showing about 2.8 times and LID could reduce efficiently yearly surface runoff with 75% reduction of increased runoff by conventional post development. LIDMOD designed detention area for volume/peak flow control with 20.2% of total area by hybrid design. LID can also efficiently reduce pollutant load from land cover. Pollutant loads from post-development without LID was much higher than those from pre-development with showing 37 times for BOD, 2 times for TN, and 9 times for TP. Pollutant loads from post-development with LID represented about 57% of those without LID. Increasing groundwater recharge reducing cooling and heating fee, creating green refuge at building area can be considered as additional benefits of LID. At the point of reducing runoff and pollutant load, LID might be important technique for Korean TMDL and LIDMOD can be useful tool to calculate unit load for the case of LID application.

월성 원자력 발전소 2,3,4호기에서의 LOCA 사고후 보조건물의 방사선장 평가 (Assessment of Post-LOCA Radiation Fields in Service Building Areas for Wolsong 2, 3, and 4 Nuclear Power Plants)

  • 진영권;김용일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.53-64
    • /
    • 1995
  • 월성 원자력발전소 2,3,4 호기의 보조건물 주요 지역에서 냉각재 다량상h7사고 (large LOCA) 후의 방사선장을 평가하였다. 핵분열 생성물의 총량은 ORIGEN2 코드를 사용하여 계산하였고 선원항은 2중고장 시나리오, 즉 LOCA 사고후 비상노심냉각 (ECC) 계통의 고장이 결부된 사고시의 방사능 방출에 근거하였다. 원자로건물, 보조건물 및 ECC 계통의 구조모형을 QAD-CG 모델에 포함하여 계산하였다. 사고시점부터 90일 경과시까지 시간대 별로 선량율과 누적선량을 계산하였다. 결과적으로, 연속출입이 요구되는 중요지역에서의 방사선장은 충분히 낮은 것으로 평가되었다. 그러나, 일부구역에서는 제한적인 출입을 허용할 정도로 상대적으로 높은 방사선장을 나타내었다.

  • PDF