• 제목/요약/키워드: cooling load

검색결과 998건 처리시간 0.023초

퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구 (A Study on Daily Cooling Load Forecast Using Fuzzy Logic)

  • 신관우;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.

수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정 (Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer)

  • 윤상윤;김재철;김기현;임진순
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

HTS변압기에서 액체질소 표면 상부의 열전달 해석 (Heat Transfer Analysis above L$N_2$ Surface in HTS Transformer)

  • 최연석;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.174-177
    • /
    • 2003
  • Cooling load from the top plate to L$N_2$ surface, including wall conduction, gas conduction, radiation, and current leads, is investigated in a closed cooling system for HTS transformer. In general methods of load calculation, individual load is estimated separately, but they are actually coupled each other because of natural convection of nitrogen vapor. Using heat transfer analysis, we calculate cooling load with taking into account the effect of natural convection. Cooling load is under- estimated approximately 2 % when the natural convection is ignored. If the operating current is high, there will be a wide difference between actual cooling load and cooling load by individual calculation. Cooling load decreases with increasing number of radiation shield. With production, construction, and cooling load, three radiation shields are proper to 1 MVA HTS transformer.

  • PDF

액체/전도냉각형 초전도 시스템에서 전류도입선의 열적 해석 (Thermal analysis of Current lead for Liquid/Conduction cooling on Superconducting system)

  • 권기범;김형진;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.178-181
    • /
    • 2003
  • Intermediate cooling for current lead is used of thermal link in conduction cooling and cooled of itself in liquid cooling because it is put in liquid. If a existing formula for cooling load and optimal diameter-length of current lead is applied, it generate some more cooling load. Therefore, variation of thermal link height and holding depth in liquid is considered. This result is used of reducing cooling load of current lead occupying most of superconducting system load and applying liquid/conduction cooling systems.

  • PDF

수경온실의 양액 냉각부하 예측모델 개발 (Development of a Numerical Model for Prediction of the Cooling Load of Nutrient Solution in Hydroponic Greenhouse)

  • 남상운;김문기;손정익
    • 생물환경조절학회지
    • /
    • 제2권2호
    • /
    • pp.99-109
    • /
    • 1993
  • Cooling of nutrient solution is essential to improve the growth environment of crops in hydroponic culture during summer season in Korea. This study was carried out to provide fundamental data for development of the cooling system satisfying the required cooling load of nutrient solution in hydroponic greenhouse. A numerical model for prediction of the cooling load of nutrient solution in hydroponic greenhouse was developed, and the results by the model showed good agreements with those by experiments. Main factors effecting on cooling load were solar radiation and air temperature in weather data, and conductivity of planting board and area ratio of bed to floor in greenhouse parameters. Using the model developed, the design cooling load of nutrient solution in hydroponic greenhouse of 1,000$m^2$(300pyong) was predicted to be 95,000 kJ/hr in Suwon and the vicinity.

  • PDF

건물의 외주부 존에 대한 동적 부하모델 이용 피크냉방부하 저감효과 분석 (Evaluation on Reducing Peak Cooling Load Based on Dynamic Load Model of Building Perimeter Zones)

  • 이경호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, inverse building modeling was applied to building perimeter zones which have different window orientation. Two test zones of east-facing and west-facing zones in ERS(Energy Resource Station) building, which is representative of small commercial building, was used to test performance of cooling load calculation and peak cooling load reduction. The dynamic thermal load model for the east and west zone was validated using measured data for the zones and then it was used to investigate the effect of peak cooling load reduction by adjustment of indoor cooling temperature set points during on-peak time period. For the east zone, the peak load can be reduced to about 60% of the peak load for conventional control even without any precooling. For the west zone, PLR is nearly independent of the start of the on-peak period until a start time of 1pm. Furthermore, PLR has a small dependence on the precooling duration. Without any precooling, the peak cooling load can be reduced to about 35% of the peak load associated with conventional control.

미래의 불확실한 냉방부하에 대한 아이스슬러리를 이용한 지역냉방시스템 (A District Cooling System using Ice Slurry for the Uncertain Cooling Load of the Future)

  • 이윤표;안영환;윤석만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.233-238
    • /
    • 2006
  • A new district cooling system using ice slurry for the uncertain cooling load of the future is presented. The chilled water produced by the absorption chillers is used for the base cooling load. The temperature of the chilled water is reduced by mixing of ice slurry depending on increasing of the cooling load. Finally, IPF of the ice slurry is increased up to 10% at the peak load. The transporting mass flow rate is decreased down to 44.7%, and the diameter of the main pipe is decreased down to 66.7%, but the diameter of the branched pipe is designed as the same size of the chilled water.

  • PDF

온실의 냉방부하 및 포그시스템의 증발효율 실험분석 (Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses)

  • 남상운;서동욱;신현호
    • 생물환경조절학회지
    • /
    • 제24권3호
    • /
    • pp.147-152
    • /
    • 2015
  • 온실의 냉방부하 산정방법 개발을 위하여 열수지 방법에 기초한 냉방부하 산정식을 구성하고, 포그냉방 온실에서 냉방부하를 실측하여 검증하였다. 포그냉방 온실의 냉각열량은 포그분사에 의한 증발수량에 물의 증발잠열을 곱하여 구할 수 있다. 여기서, 증발수량은 포그 분사량에 증발효율을 곱하면 구할 수 있으며, 즉 분무수량을 계측하고 포그시스템의 증발효율을 알면 온실의 냉방부하를 실측할 수 있다. 따라서 온실의 냉방부하 실측을 위하여 실험온실에서 포그시스템의 증발효율을 실험하고, 실험온실의 열환경 계측과 더불어 포그 분사량을 계측하여 냉방부하 산정방법을 검토하였다. 먼저 냉방부하 산정식의 환기전열량을 검토하기 위하여 냉방을 실시하지 않은 상태에서 환기량 실측 실험을 통해 비교한 결과 열수지식을 이용한 환기전열량 예측은 비교적 양호한 결과를 보이는 것으로 나타났다. 이류체 포그시스템의 증발효율은 0.3~0.94의 범위를 보였으며 평균 0.67로 나타났고, 환기율이 증가함에 따라 커지는 것으로 나타났다. 포그냉방을 실시하면서 온실의 환경을 계측하여 열수지식으로 냉방부하를 계산하고, 분무량 실측치로부터 증발 냉각열량을 구하여 비교한 결과 냉방부하 계산치와 실측치는 대체로 유사한 경향을 보이는 것으로 나타났다. 냉방부하가 낮은 경우에는 실측치에 비하여 약간 크게 예측되었고, 냉방부하가 높은 경우에는 실측치보다 작게 예측되었다. 온실의 냉방시스템 설계 시에는 최대냉방부하를 이용하여 냉방설비의 용량을 결정하게 된다. 따라서 냉방부하가 큰 쪽에서 실측치보다 작게 예측되는 부분은 검토가 필요하지만 설비용량 산정시의 안전계수를 고려하면 본 연구에서 제시한 냉방부하 산정방법은 온실의 환경설계에 적용할 수 있는 것으로 판단된다.

신경회로망을 이용한 냉방부하예측에 관한 연구 (The Study on Cooling Load Forecast using Neural Networks)

  • 신관우;이윤섭
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.626-633
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity, The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data is approached to the actual data.