• 제목/요약/키워드: cooling channel

검색결과 437건 처리시간 0.024초

수직형 건식 진공 스크류 펌프의 열특성에 대한 연구 (A Study on the Thermal Characteristics of Dry Vacuum Pump with Vertical Screws)

  • 장문석;박재현;김수태;김일곤;조성진
    • 한국기계가공학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, analysis and experiments were carried out on temperature distributions and thermal deformations in a dry vacuum pump with vertical screws for safe operation. When a vacuum pump is working, it is necessary to get rid of the heat generated by the friction of bearings and the compression of air to prevent the vacuum pump from being damaged by interference between two screws and housing through thermal deformation. Additional cooling was proposed by using oil flow through the inner channel of the rotating axis for lower temperature control of the vacuum pump. Analysis and experimental results were compared in terms of temperature distribution and thermal deformation of the vacuum pump, and two sets of results matched reasonably well. These results for a dry vacuum pump with vertical screws can be used in similar model development and can minimize errors in design and manufacture by providing reasonably accurate prediction in advance.

우리나라-노르웨이 고등어산업의 유통 경쟁력 비교 연구 (Comparison of Distribution Competitiveness of the Mackerel Industry between Korea and Norway)

  • 김대영;강종호
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1685-1692
    • /
    • 2015
  • This study examines the mackerel distribution systems in Norway which has a leading mackerel industry, and has the purpose of analyzing the effects of structural improvements for the development of Korea's mackerel industry. The landing and distribution status of Korea and Norway's mackerel industry was compared, and the effects of structural improvements was analyzed under the assumption that a number of factors would be improved after an analysis of competitiveness. Special features of the landing and distribution systems of mackerel in Norway are Reduction of transportation costs and transportation time through E-auctions, fish Pumps, freshness management using state-of-the-art equipment and technology such as sea water cooling systems, direct landing at processing factories and Automation through fully automated sorting & packaging systems. The distribution competitiveness of Korea and Norway's mackerel industry was compared through the qualitative review of landing time and the length of distribution channel, distribution costs due to differences in trading method, quality and hygiene management and merchandising. For Korea's mackerel industry to have international competitiveness, they must have efficiency throughout the phases of landing, processing and distribution systems as observed in case of Norway.

재생냉각용 연소기의 브레이징 공정 개발

  • 홍석호;한규석;우유철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2000년도 제14회 학술강연논문집
    • /
    • pp.36-36
    • /
    • 2000
  • 액체로켓엔진에 사용되는 2000psi이상의 고압 연소실(Combustion Chamber)의 냉각은 내피(Inner Shell)에 기계 가공된 냉각통로(Cooling Channel)로 냉각제를 흘려보내는 재생냉각방식이 널리 사용되며 기계 가공된 냉각 통로는 외피(Outer Shell)에 의해서 지지 밀봉된다. 일반적으로 내피 재료는 순수한 구리보다 강도가 우수하고 열전도도는 유사한 구리합금을 사용하고, 외피는 강도가 우수한 스테인레스 강을 사용하여 브레이징 접합된 구조를 형성한다. 브레이징 공정은 조립품을 약 $450^{\cire}C$ 이상의 액상선을 갖는 삽입금속(Filler Metal)을 사용하여 적당한 온도($450^{\cire}C$ ~ 모재의 고상선)에서 가열하여 접합시키는 방법으로, 용융 금속의 젖음 현상(Wetting Phenomena), 접합 틈새(Joint Clearance)로의 용융 삽입금속의 유입(Capillary Phenomena)과 접합 계면의 반응을 통해서 접합이 이루어진다. 이는 일반적인 접합 공정과 비교하여 모재의 변형이 적고, 이종 금속 간의 접합이 용이하며, 복잡한 부품을 정밀하게 접합할 수 있는 장점이 있으나, 접합될 제품의 표면 상태 및 분위기(Atmosphere), 접합될 부품간의 조립 틈새, 가열 싸이클(Heating Cycle) 등에 대한 공정 확립 및 관리가 매우 중요하다. 재생냉각 구조를 갖는 연소실은 우선 접합면의 형상이 매우 복잡하여 균일한 접합 틈새를 유지하면서 접합시키기가 매우 어려우며, 고온, 고압의 환경에서 작동하므로 일부 접합면이 접합되지 않을 경우 내피의 변형 및 파괴가 발생하고, 브레이징 시 용융된 삽입금속이 냉각통로 내로 유입될 경우 연소 시 이부근에서 재료의 용융이 발생될 수 있다. 따라서, 이러한 현상을 방지하기 위해서는 진공 분위기 하에서 적절한 접합 틈새를 유지할 수 있는 공정 및 장비의 개발이 필요하다.

  • PDF

원자력 발전소용 순환수 펌프의 성능해석 (THE PERFORMANCE ANALYSIS OF A CWP PUMP FOR A NUCLEAR POWER PLANT)

  • 이명수;한병윤;황도연;유성수;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.232-238
    • /
    • 2009
  • The objective of this study is to investigate the suitable design for a domestic CWP pump, which is used in cooling-water intakes for the unit 3 and 4 of Yeonggwang nuclear power plant. All the simulations are performed, using CFD method with a commercial code STAR-CCM+ version 3.02. After modeling a present design of the pump, the flow around the rotating blade was calculated by using quasi-static method and sliding mesh method with the almost same condition as an actual state. Based on fundamental simulations with various depth of sea water, the reference pressure for the boundary condition of the present study was decided. To verify the reliability of the calculation results, the suction flow rate of the data was compared with that of the experimental data. As a result of this comparison, it is confirmed that two results are fairly consistent. For the improvement of the suction flow rate, computational analysis was done by changing a flow channel and blade shapes. It is shown that the suction flow rate of the new pump was improved.

  • PDF

열량계 채널에 대한 3차원 열전달 해석

  • 박태선;설우석
    • 항공우주기술
    • /
    • 제2권2호
    • /
    • pp.142-150
    • /
    • 2003
  • 가열벽이 있는 4각단면 채널에서 3차원 열전달이 비선형 k-ε-fμ 모형과 큰에디모사법을 이용하여 해석되었다. 4각단면 채널로 모형화된 열량계 해석에 비선형 k-ε-fμ 모형과 비선형 열유속모형이 도입되었다. 레이놀즈수는 4000≤$Re_b$≤20000로 변화되었다. 난류의 비등방성으로 유도되는 구석와류는 주 유동속도의 1~3% 정도로 크지 않았지만 열전달에 커다란 영향을 주었다. 또한 채널 단면에 존재하는 나선형의 와류에 의해서 열전달이 심하게 변함을 보여 주었다. 예측된 열전달계수로부터 Nu~$Re^{0.8}Pr^{0.34}$가 검토되었고 온도의 섭동과 와유동의 비정상거동이 조사되었다.

  • PDF

Study on the global distribution of far-ultraviolet emission in our Galaxy

  • Jo, Young-Soo;Seon, Kwang-Il;Min, Kyoung-Wook;Edelstein, Jerry
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.52.1-52.1
    • /
    • 2015
  • FIMS/SPEAR is a dual-channel far-ultraviolet imaging spectrograph on board the Korean microsatellite STSAT-1, which was launched on 2003 September 27. The primary mission goal of FIMS was to conduct a survey of diffuse far UV emissions in our Galaxy. For this purpose, FIMS completed a survey of about 84% of the sky during its operation of a year and a half. The present study aims to analyze this survey data made in the far UV wavelengths to understand the global evolution of our Galaxy. The far UV wavelength band is known to contain important cooling lines of hot gas: hence, the study will show how the hot gas in our Galaxy, produced by stellar winds and supernova explosion, evolves globally to cool down and become mixed with ambient cooler medium. One of the main findings from previous analyses of the FIMS data is that molecular hydrogen exists ubiquitously in our Galaxy. This discovery leads to another important scientific question: how is molecular hydrogen distributed in our Galaxy and how does it affect globally the evolution of our Galaxy as a cold component? Hence, the present study will cover both the hot and cold components of the ISM, which will also provide the opportunity to investigate the interactions between the two.

  • PDF

다양한 부채꼴 핀휜 형상의 열성능 평가 (Evaluation of Thermal Performances of Various Fan-Shaped Pin-Fin Geometries)

  • 문미애;김광용
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.557-570
    • /
    • 2014
  • 본 연구에서는 삼차원 RANS 방정식을 이용하여 냉각 유로 내에 부착하는 새로운 핀휜의 다양한 부채꼴 형상에 대해 열전달, 압력강하, 열성능을 평가하였다. 레이놀즈수가 5,000부터 100,000인 경우에 대하여 수치해석을 수행하였으며, 난류모델로는 Low-Re SST 모델을 사용하였다. 수치해석의 정당성을 확보하기 위하여 실험과 동일한 조건에서 면적 평균 누셀트수에 대한 실험값과 계산값을 비교하였다. 앞전 각도와 뒷전 각도를 매개변수로 하여 세 종류의 부채꼴 핀휜의 형상 변화에 따른 열성능을 평가하였다.

열발전소 배수암거 부정류해석 수치모형의 개발 : II. 모형의 적용 (Development of Numerical Model for Unsteady Flow Analysis jin Discharge Culvert of Thermal Power Plant: II. Model Application)

  • 윤성범;이기혁
    • 한국수자원학회논문집
    • /
    • 제30권6호
    • /
    • pp.769-776
    • /
    • 1997
  • 윤성범과 이기혁(1977)의 수치모형을 이용하여 열발전소의 펌프 비상중단시 냉각수 계통에서 발생하는 서어지거동을 해석하였다. 종래에 무시되었던 기계내부계통으로 부터의 유량, 폐정공기실, 및 공기유출입구, 맨홀, 개수로 및 바다의 영향을 고려하였으며, 이들이 서어지 거동에 미치는 영향을 체계적으로 분석하였다. 특히 공기유출입구의 면적에 따른 서어지 제어효과와 공기실의 공기압 변화를 제시하여 실무에의 적용이 용이하도록 하였다.

  • PDF

원자력 발전소용 순환수 펌프의 성능해석 (THE PERFORMANCE ANALYSIS OF A CIRCULATING WATER PUMP FOR A NUCLEAR POWER PLANT)

  • 이명수;한병윤;황도연;유성수;박형구
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to investigate the suitable design for a domestic Circulating water pump(CWP), which is used in cooling-water intakes for the unit 3 and 4 of Yeonggwang nuclear power plant. All the simulations are performed, using CFD method with a commercial code STAR-CCM+ version 3.02. After modeling a present design of the pump, the flow around the rotating blade was calculated by using quasi-static method and sliding mesh method with the almost same condition as an actual state. Based on fundamental simulations with various depth of sea water, the reference pressure for the boundary condition of the present study was decided. To verify the reliability of the calculation results, the suction flow rate of the data was compared with that of the experimental data. As a result of this comparison, it is confirmed that two results are fairly consistent. For the improvement of the suction flow rate, computational analysis was done by changing a flow channel and blade shapes. It is shown that the suction flow rate of the new pump was improved.

Preliminary Study on the Elemental Quantification of in Ambient Liquid Samples of Microliter Volume Using the In-air Micro-PIXE Technique

  • Ma, Chang-Jin;Lim, Cheol-Soo;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권1호
    • /
    • pp.54-60
    • /
    • 2017
  • Quantifying the trace elements in infinitesimal ambient liquid samples (e.g., single raindrop, cloud/fog water, and the soluble fraction extracted from the particles collected for a short time) is an important task for understanding formation processes, heating/cooling rates, and their health hazards. The purpose of this study is to employ an in-air micro PIXE system for quantitative analysis of the trace elements in a thimbleful of reference liquid sample. The bag type liquid sample holder originally designed with $10{\mu}m$ thick $Mylar^{(R)}$ film retained the original shape without any film perforation and apparent peaks of film blank by the end of the analysis. As one of tasks to be solved, the homogeneity of the elemental distribution in liquid reference species was verified by the X-ray line profiles for several references. It was possible to resolve the significant peaks for whole target elements corresponding to the channel number of micro-PIXE spectrum. The calibration curves for the six target elements (Si, S, Cl, Fe, Ni, and Zn) in standard solutions were successfully plotted by concentration (ppm) and ROI of interest net counts/dose (nC).