• Title/Summary/Keyword: coolant

Search Result 1,617, Processing Time 0.03 seconds

Effect of Boundary Conditions on Internal Coolant Flow in Gas Turbine Blades (경계 조건이 가스터빈 블레이드 냉각공기 유량에 미치는 영향)

  • Shin, Jee-Young;Park, Byung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.559-564
    • /
    • 2001
  • Advanced gas turbine engines employ turbine entry temperatures so high that cooling of the turbine blades is essential. The coolant flow introduces losses which need to be minimized, and therefore it is important that the minimum amount of coolant is used. This work presents the result of the one-dimensional analysis and the effect of the boundary conditions on coolant flow rate in gas turbine blades.

  • PDF

Effect of Boundary Condition on the Flow Rate of the Internal Coolant in Gas Turbine Blades (경계조건에 따른 가스터빈 블레이드 냉각공기 유량변화)

  • 신지영;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.888-894
    • /
    • 2001
  • Advanced gas turbine engines employ turbine entry temperatures so high that cooling of the turbine blades is essential. The coolant flow introduces losses which need to be minimized, and therefore it is important that the minimum amount of coolant should be used. This work presents the result of the one-dimensional analysis and the effect of the boundary conditions on coolant flow rate in gas turbine blades.

  • PDF

Reliability Analysis and Feilure Mechanisms of Coolant Rubber Hose Materials for Automotive Radiator (자동차 냉각기 고무호스용 재질에 대한 신뢰성 평가 및 고장메커니즘규명)

  • Kwak Seung-Bum;Choi Nak-Sam;Kang Bong-Sung;Shin Sei-Moon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.152-162
    • /
    • 2005
  • Coolant rubber hoses for automobile radiators can be degraded and thus failed due to the influence of contacting stresses of air and coolant liquid under the thermal and mechanical loadings. In this study, test analysis was carried out for evaluating the degradation and failure mechanisms of coolant hose materials. Two kinds of EPDM rubber materials applicable to the hoses were adopted: commonly-used ethylene-propylene diene monomer(EPDM) rubbers and EPDM rubbers with high resistance against electro-chemical degradation (ECD). An increase of surface hardness and a large reduction of failure strain were shown due to the formation of oxidation layer for the specimens which had been kept in a high temperature air chamber. Coolant ageing effects took place only by an amount of pure thermal degradation. The specimens degraded by ECD test showed a swelling behavior and a considerable increase in weight on account of the penetration of coolant liquid into the skin and interior of the rubber specimens. The ECD induced material softening as well as drastic reduction in strength and failure strain. However EPDM rubbers designed for high resistance against ECD revealed a large improvement in reduction of failure strain and weight. This study finally established a procedure for reliability analysis and evaluation of the degradation and failure mechanisms of EPDM rubbers used in coolant hoses for automobile radiators.

PRELIMINARY ESTIMATION OF ACTIVATED CORROSION PRODUCTS IN THE COOLANT SYSTEM OF FUSION DEMO REACTOR

  • Noh, Si-Wan;Lee, Jai-Ki;Shin, Chang-Ho;Kwon, Tae-Je;Kim, Jong-Kyung;Lee, Young-Seok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.63-69
    • /
    • 2012
  • The second phase of the national program for fusion energy development in Korea starts from 2012 for design and construction of the fusion DEMO reactor. Radiological assessment for the fusion reactor is one of the key tasks to assure its licensability and the starting point of the assessment is determination of the source terms. As the first effort, the activities of the coolant due to activated corrosion product (ACP) were estimated. Data and experiences from fission reactors were used, in part, in the calculations of the ACP concentrations because of lack of operating experience for fusion reactors. The MCNPX code was used to determine neutron spectra and intensities at the coolant locations and the FISPACT code was used to estimate the ACP activities in the coolant of the fusion DEMO reactor. The calculated specific activities of the most nuclides in the fusion DEMO reactor coolant were 2-15 times lower than those in the PWR coolant, but the specific activities of $^{57}Co$ and $^{57}Ni$ were expected to be much higher than in the PWR coolant. The preliminary results of this study can be used to figure out the approximate radiological conditions and to establish a tentative set of radiological design criteria for the systems carrying coolant in the design phase of the fusion DEMO reactor.

The Study on a Real-time Flow-rate Calculation Method by the Measurement of Coolant Pump Power in an Integral Reactor (일체형원자로에서 냉각재펌프의 전력측정을 이용한 실시간 유량산정 방법에 관한 연구)

  • Lee, J.;Yoon, J.H.;Zee, S.Q.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.161-166
    • /
    • 2003
  • It is the common features of the integral reactors that the main components of the RCS are installed within the reactor vessel, and so there are no any flow pipes connecting the coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the RCS of the integral reactors, and it also makes impossible measure the flow-rate of the reactor coolant. As a alternative method, the method by the measurement of coolant pump power has been introduced in this study. Up to now, we did not found out a precedent which the coolant pump power is used for the real-time flow-rate calculation at normal operation of the commercial nuclear power plants. The objective of the study is to embody the real-time flow-rate calculation method by the measurement of coolant pump power in an integral reactor. As a result of the study, we could theoretically reason that the capacity-head curve and capacity-shaft power curve around the rated capacity with the high specific-speeded axial flow pumps have each diagonally steep incline but show the similar shape. Also, we could confirm the above theoretical reasoning from the measured result of the pump motor inputs, So, it has been concluded that it is possible to calculate the real-time flow-rate by the measurement of pump motor inputs. In addition, the compensation for a above new method can be made by HBM being now used in the commercial nuclear power plants.

  • PDF

Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating (냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kim, Tong-Seop;Kim, Jae-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

A Study on the Two Phase Flow in the Floor of Containment Building after a Loss of Coolant Accident (냉각재 상실사고 후 격납건물내의 이상유동 연구)

  • Bae, Jin-Hyo;Park, Man Heung;Koh, Chul-Kyun;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1274-1284
    • /
    • 1999
  • The Regulatory Guide 1.82 recommends an analysis of hydraulic performance for sump of ECCS (Emergency Core Cooing System) when LOCA(Loss of Coolant Accident) occurs in a nuclear power plant. The present study deals with 3-dimensional, unsteady, turbulent and two-phase flow simulation to examine the behavior of mixture of reactor coolant and debris near the floor of containment building in conjunction with appropriate assumptions. The dispersed solid model has been adjusted to the interfacial momentum transfer between reactor coolant and debris. According to the results, the counterclockwiserecirculation zone had been formed in the region between sump and connection aisle about 376 second after LOCA occurs. The debris thickness accumulated on a sump screen periodically increases or decreases up to 2000 second, afterwards its peak decreases.

Freeze and MechanicalProperties of Cement Mortar Using Coolant Wasted (폐부동액을 이용한 시멘트 모르터의 동결 및 역학적 특성)

  • Kim, Sang-Woo;Hong, Sang-Hee;Kim, Gi-Cheol;Ryu, Hyun-Ki;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.169-172
    • /
    • 2000
  • In this paper applicabilities of coolant wastes are an admixture, which are produced from cooling line of the cars and industrial engines, to concrete under cold climate are investigated. According to the test results, as the contents f coolant wastes increase, setting time of cement mortar is shown to be delayed. However, when coolants wastes are overadded, it appears to be fast. In case of compressive strength, It tends to decline as the contents of coolant waste increase. Under low curing temperature, compressive strength of cement mortar containing coolant wasted with the increase of the contents of coolants wastes.

  • PDF

A Study on the Reduction of HC Emissions by Fuel Injection Methods during the SI Engine Start (가솔린기관의 시동시 연료분사기법에 의한 HC 배출저감 연구)

  • Kim, Seong-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.257-262
    • /
    • 2003
  • Engine-out HC emissions were investigated during engine start. The tests were conducted on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine at different coolant temperatures and fuel injection-skip methods; no skip, 1 cycle-skip and 3 cycle-skip. To understand the characteristics of engine-out HC emissions, HC concentration was measured at a exhaust port using a Fast Response Flame Ionization Detector (FRFID). The result show that HC emissions were emitted at the cold coolant temperature much higher than those of the hot coolant. In additions, the fuel injection skip highly reduced engine-out HC emissions. It is convinced that optimized fuel injection skips according to coolant temperatures could be applied to reduce HC emissions during SI engine start.

  • PDF

Structural Integrity Evaluation for the Reactor Coolant Pump Shaft Seal Assembly (원자로냉각재펌프 축밀봉장치에 대한 구조적 건전성 평가)

  • Kim, Minsu;Kim, Minchul;Kim, Oaksug;Chung, Sungho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.2
    • /
    • pp.44-50
    • /
    • 2017
  • The shaft seal of the reactor coolant pump is installed on the upper side of the rotating shaft of the pump to seal the reactor coolant from flowing out between the rotating shaft and the non-rotating parts. In this study, the loading conditions for the normal operation and faulted conditions are identified and structural integrity evaluation is performed using the finite element stress analysis for the sealing apparatus of the APR 1400 reactor coolant pump. It is confirmed that the stress analysis results satisfy the design criteria at all loading conditions.