Structural Integrity Evaluation for the Reactor Coolant Pump Shaft Seal Assembly |
Kim, Minsu
((주)두산중공업)
Kim, Minchul ((주)두산중공업) Kim, Oaksug ((주)두산중공업) Chung, Sungho ((주)두산중공업) |
1 | Min-Chul Kim, Sang-Youn Bang, Ki-Won Lee, Young-Jin Choi and Yong-Su Kim, 2010, "Structural Integrity Assessment of the Pump Shaft Assembly of the APR1400 Reactor Coolant Pump", ASME 2010 Pressure Vessels and Piping Division/K-PVP Conference, Vol.9, Bellevue, Washington, USA, pp. 45-50. |
2 | Ikjoong Kim, Dohyun Lim, Min-Chul Kim, Sang-Youn Bang, 2014, "Introduction of Vibration Evaluation for APR 1400 Reactor Coolant Pump Shaft", Proceedings of the Korean Society for Noise and Vibration Engineering Conference, 2014.10, pp. 110-115. |
3 | KEPIC MNB, 2000 Edition, 2001, 20002 and 2003 Addenda. |
4 | KEPIC MNZ, 2000 Edition, 2001, 20002 and 2003 Addenda. |
5 | KEPIC MDP, 2000 Edition, 2001, 20002 and 2003 Addenda. |
6 | E. Mayer, "Mechanical Seals 3rd edition", Butterworth-Heinemann, 1982 Reprint, pp. 1-34. |