• 제목/요약/키워드: converter model

검색결과 781건 처리시간 0.028초

DC 마이크로 그리드를 위한 Three-port Dual Active Bridge DC-DC 컨버터의 독립 전력 제어 (Decoupled Power Control of Three-port Dual Active Bridge DC-DC Converter for DC Microgrid Systems)

  • 심주영;이준영;최현준;김학선;정지훈
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.366-372
    • /
    • 2018
  • Three-port dual-active bridge (DAB) converter in a DC microgrid was studied due to its high power density and cost-effectiveness. The other advantages of DAB include galvanic isolation and bidirectional power conversion capability using simple control modulation. The three-port DAB converter consists of a three winding transformer and three bridges. The transformer has three phases, which means that the ports are coupled. Thus, the three-port DAB converter causes unwanted power flows when the load connected to each port changes. The basic operational principles of the three-port DAB converter are presented in this study. The decoupling control strategy of the independent port power transfer is presented with a mathematical power model to overcome the unexpected power flow problem. The validity of the proposed analysis and control strategy is verified with PSIM simulation and experiments using a 1-kW prototype power converter.

A New Waveshaper for Harmonic Mitigation in Vector Controlled Induction Motor Drives

  • Singh, Bhim;Garg, Vipin;Bhuvaneshwari, G.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.152-161
    • /
    • 2008
  • This paper deals with a new wave shaping technique for cost effective harmonic mitigation in ac-dc converter feeding Vector Controlled Induction Motor Drives(VCIMD's) for improving power quality at the point of common coupling(PCC). The proposed harmonic mitigator consists of a polygon connected autotransformer based twelve-pulse ac-dc converter and a small rating passive shunt filter tuned for $11^{th}$ harmonic frequency. This ac-dc converter eliminates the most dominant $5^{th},\;7^{th},\;and\;11^{th}$ harmonics and imposes the reduction of other higher order harmonics from the ac main current, thereby improving the power quality at ac mains. The design of autotransformer is carried out for the proposed ac-dc converter to make it suitable for retrofit applications, where presently a 6-pulse ac-dc converter is used. The effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed ac-dc converter in a wide operating range of the drive. Experimental results obtained on the developed laboratory prototype of the proposed harmonic mitigator are used to validate the model and design of the ac-dc converter.

유한요소법을 이용한 LD - 전로의 노저부 형상에 따른 응력분포의 해석 (The Stress Distribution Analysis of LD - converters with Different Edge Shapes by FEM)

  • 김성순;한봉석;허완욱;하창수;이형직;이홍림
    • 한국세라믹학회지
    • /
    • 제38권9호
    • /
    • pp.829-833
    • /
    • 2001
  • 전로 내화물의 화학적인 부식에 대해서는 많은 연구가 이루어져 왔다. 그러나 전로 내화물의 자체 무게와 구조적인 형상으로 발생되는 응력집중에 의한 내화물의 부식에 대해서는 그 연구가 미비한 실정이다. 따라서 본 연구에서는 각이 진 노저부 형상을 가지는 전로(모델 1)와 완만한 곡선 형상을 가지는 전로(모델 2)에 대하여 FEM을 이용하여 자중응력분포 시뮬레이션을 행하고 그 결과를 비교분석 하였다. 시뮬레이션결과 슬래그 라인 근방에서 모델 2가 모델 1보다 높은 응력값을 나타내었다. 따라서 열적${\cdot}$화학적인 요인을 모두 고려한다면 조업 중기에 모델 2의 슬래그 라인 근방에서의 부식이 모델 1에 비해 심각할 것이라 결론 내릴 수 있다.

  • PDF

시지연과 SVPWM 영향이 고려된 새로운 제어 모델에 의한 3상 전압원 PWM 컨버터의 전류 제어 (Current Control of a 3$\phi$ PWM Converter Based on a New Control Model with a Delay and SVPWM effects)

  • 민동기;안성찬;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2018-2020
    • /
    • 1998
  • In design of a digital current controller for a 3$\phi$ voltage-source (VS) PWM converter, its conventional model, i.e., stationary or synchronous reference frame model, is used in obtaining its discretized version. It introduces, however, inherent errors since the following practical problems are not taken into consideration: the characteristics of the space vector-based pulsewidth modulation (SVPWM) and the time delays in the process of sampling and computation. In this paper, the new hybrid reference frame model of the 3$\phi$ VS PWM converter is proposed considering these problems. In addition, the direct digital current controller based on this model is designed without any prediction or extrapolation algorithm to compensate the time delay. So the control algorithm is made very simple. The validity of the proposed algorithm is proved by the computer simulation results.

  • PDF

The Optimal Controller Design of Buck-Boost Converter by using Adaptive Tabu Search Algorithm Based on State-Space Averaging Model

  • Pakdeeto, Jakkrit;Chanpittayagit, Rangsan;Areerak, Kongpan;Areerak, Kongpol
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1146-1155
    • /
    • 2017
  • Normally, the artificial intelligence algorithms are widely applied to the optimal controller design. Then, it is expected that the best output performance is achieved. Unfortunately, when resulting controller parameters are implemented by using the practical devices, the output performance cannot be the best as expected. Therefore, the paper presents the optimal controller design using the combination between the state-space averaging model and the adaptive Tabu search algorithm with the new criteria as two penalty conditions to handle the mentioned problem. The buck-boost converter regulated by the cascade PI controllers is used as the example power system. The results show that the output performance is better than those from the conventional design method for both input and load variations. Moreover, it is confirmed that the reported controllers can be implemented using the realistic devices without the limitation and the stable operation is also guaranteed. The results are also validated by the simulation using the topology model of MATLAB and also experimentally verified by the testing rig.

통신위성 배터리 충,방전기 설계 및 해석 (Design and Analysis of a Battery Charge and Discharge Regulator of Communication Satellite)

  • 최재동
    • 한국항공우주학회지
    • /
    • 제31권7호
    • /
    • pp.118-126
    • /
    • 2003
  • 본 연구에서는 모듈형태의 배터리 충-방전기가 정상상태뿐만 아니라 과도상태에서 예기치 못한 결함이 발생할지라도 실패 없이 전원을 공급하는 것이 가능한 병렬형 양방향 컨버터로 설계되어졌다. 컨버터 모듈은 안정성, 성능 및 고신뢰성을 얻기 위해 독립적인 제어가 가능하도록 설계되었으며, 제어기를 위해 사용된 평균전류모드방식은 노이즈 면역, 빠른 응답 및 평균전류 신호 획득과 같은 장점을 갖는다. 병렬 연결된 배터리 충-방전기에 대한 등가모델이 제시되었으며, 충전연속모드, 방전연속/불연속 모드에 대한 전달함수가 분석되었다. 병렬 양방향 컨버터는 스텝 부하변화와 하나의 컨버터 모듈 실패에 대해 각각 수행되었다. 그리고 병렬 양방향 컨버터의 성능이 실험결과들을 통해 검증되었다.

A STUDY ON A CATALYTIC CONVERTER OBD BEFORE LIGHT-OFF

  • Yun, Seung-Won;Son, Geon-Seog;Lee, Kwi-Young
    • International Journal of Automotive Technology
    • /
    • 제3권1호
    • /
    • pp.33-40
    • /
    • 2002
  • Increasingly stringent emission regulations of EU and CARB (California Air resource Board) require mandatory OBD (On Board Diagnostics) far the catalytic converters of a vehicle. It demands that MIL(Malfunction Indication Light) should be tuned on to inform the driver of catalytic converter failures. Currently dual oxygen sensor method Is widely used for the converter OBD. However, since it works only alter converter light-off, it has a serious limitation when applied to TLEV or more stringent emission regulations where more than 85% of total emission is coming out before converter light-off. In addition, a recent development in catalyst material. coating technology and additive catalysts leads to a much improved OSC (Oxygen Storage Capacity) after converter light-off, current methods are very difficult to determine levels of converter aging. Therefore, it is desired to develop an OSC detecting method before converter light-off to diagnose converter failures with higher reliability. In this study, OSCs of converters are measured by an absolute measuring method and a dynamic measuring method, and some of fundamental ideas are suggested about converter OBD before converter light-off. The converters are aged with two different aging methods; those are a furnace aging and an engine bench aging: to represent aging conditions in actual field applications. Dual oxygen sensor method at the lower temperature than light-off is also studied at a model gas bench with the converters. It is fecund that there is a certain point in temperature lower than light-off where difference due to aging level becomes maximum, thus a proper dynamic method to effectively monitor catalytic converters could be implemented fur the range lower than light-off temperatures. With this result, the aging level of converters is examined at an engine bench.

IGBT-MOSFET 병렬 스위치를 이용한 고효율 직류-직류 변환기 (High Efficiency DC-DC Converter Using IGBT-MOSFET Parallel Swit)

  • 장동렬;서영민;홍순찬;윤덕용;황용하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.460-465
    • /
    • 1998
  • Due to high power ratings and low conduction loss, the IGBT has become more attractive in switching power supplies. However, its turn-on and turn-off characteristics cause severe switching loss and switching frequency limitation. This paper proposes 2.4kW, 48V, high efficiency half-bridge DC-DC converter using paralleled IGBT-MOSFET switch concept, where each of IGBT and MOSFET plays its part during on-periods and switching instants. The switching loss is analyzed by using the linearized model and the opteration of the converter are investigated by simulation results.

  • PDF

출력 전압 맥동감소를 위한 직렬공진형 변환기의 제어기 설계 (Controller Design of the Series Resonant Converter for Reducing Output Voltage Ripple)

  • 김만고;한재원;윤명중
    • 대한전기학회논문지
    • /
    • 제37권6호
    • /
    • pp.376-382
    • /
    • 1988
  • A small-signal low-frequency disturbance of the input line affects the regulated-output voltage of the series resonant converter. To mitigate the detrimental effect, the output feedback PI-controller is employed. Small-signal linear models are represented to characterize the closed loop series resonant converter system. Design equations for the PI-controller which satisfy stability and percent ripple conditions are derived from the closed-loop linear model. Experimental results are presented which show excellent correlation with theory.

  • PDF

웹기반 아크용접 모니터링 감시 기술 (Web based ARC welding monitoring system)

  • 김태진;전진홍;박성우;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1278-1280
    • /
    • 2004
  • In this paper, we propose a new diagnosis method of DC/DC converter aging. The method is based on the variations of parasitic resistor for the aging process. We apply an on-line diagnosis of DC/DC converter because the observation is not a device, but a system. This study proposes a method of DC/DC converter diagnosis by analyzing the variations of model on the variations of parasitic resistor.

  • PDF