• Title/Summary/Keyword: conversion of units

Search Result 157, Processing Time 0.03 seconds

A Study on Historical and Cultural Viewpoints of Traditional Measuring Units Conversion (전통적인 길이 척도 환산에 대한 역사·문화적 재고)

  • Lee, DongMyung;Kim, JaeHyo;Kang, YeonSeok;Ko, HoKyoung
    • The Journal of Korean Medical History
    • /
    • v.23 no.2
    • /
    • pp.15-22
    • /
    • 2010
  • Currently, in Korea, all lengths are written in "meter" unit, and the non-statutory measuring units are banned for use. However, in some fields, traditional measuring units are widely used with necessary modifications, and people in such fields raise varying arguments on conversion to "meter" unit. This research examines traditional measuring units from historical and cultural viewpoints, and provides suggestions on how to improve consistency and standardization for more accurate and effective exchangeof scientific opinions.

INFLUENCE OF TIP DISTANCE ON DEGREE OF CONVERSION OF COMPOSITE RESIN IN CURING WITH VARIOUS LIGHT SOURCES (광원에 따른 조사거리의 증가가 복합레진의 중합도에 미치는 영향)

  • Kim, Sang-Bae;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.273-279
    • /
    • 2004
  • Recently, newly developed single high-intensity LED curing lights for composite resins are claimed to have a higher intensity than previous LED curing lights and to results in optimal properties and short curing time. The purpose of this study was to determine the curing effectiveness of the curing units and to evaluate the relationship between the degree of polymerization and distance from curing light tip end to resin surface. One composite resin was tested(Filtek Z250). Thin film specimens were cured with a LED curing unit(Elipar Freelight 2, 10s), Plasma Arc curing unit(Flipo, 6s), Halogen curing light(XL3000, 20s) at four curing light tip to the resin surface(0mm, 2mm, 4mm, 6mm). Degree of conversion of composite resins were determined by a Fourier Transform Infrared Spectrometer(FTIR). From the present study, the following results were obtained. 1. In all curing units, relative light intensity was significantly decreased according to the increase of distance of light tip to the resin surface(p<0.05). LED curing units showed a higher percentile decrease in intensity than other curing units. 2. In all curing units, degree of conversion was decreased as increase of the distance but no statistically significant difference(p>0.05) except between 4mm and 6mm(p<0.05). 3. When comparing degree of conversion of light curing units at each distance(0mm, 2mm, 4mm, 6mm), LED curing light had a higher degree of conversion than plasma arc and halogen curing lights at 0, 2, 4mm(p<0.05). At 6mm, there was a no significant difference among the curing units(p>0.05).

  • PDF

Mesoscopic Solvent Dynamics in a Real Dimensional System

  • Lee, Song-Hi
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1893-1897
    • /
    • 2004
  • Hydrodynamic simulations of mesoscopic solvent have been performed by multi-particle collision algorithm in a real dimensional system without and with the random shifting of the grid. A systematic conversion of the dimensionless units to a real dimensional system was confirmed by jump rates of solvent particles. Speed distributions of solvent particles obtained from the simulations agreed very well with the Maxwell-Boltzmann distributions. Solvent viscosities obtained from the simulations and from the conversion of units are exactly the same which confirmed the correct conversion of the units once again. The calculation of the friction coefficient of a massive Brownian particle in a mesoscopic solvent as a function of Brownian particle diameter was examined as an example.

A Guide to Education on Unit Transformation in University Liberal Arts Education (대학 교양교육에서 단위변환에 대한 교육 방향 제시)

  • kyung a jeong;hye jeong kim
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.133-138
    • /
    • 2023
  • After the SI system of units was adopted as an international system of units, Korea made a lot of efforts such as administrative and educational guidance on the traditional units that had been used so far. In addition, from July 1, 2007, the government has cracked down on the denotation of non-statutory units of measurement as standard units or auxiliary units in commercial transactions. However, non-statutory weighing units are still used in other forms. It is believed that this is because non-statutory units (= our traditional units) are permeated in our lives and are convenient to use. The general public still finds it difficult to use and mark the SI system of units correctly. This is not a problem unique to Korea. However, if you look at the books that are currently used as university physics textbooks, the SI system of units and the non-legal units of other countries are marked in such a way that they can be accurately converted. Only the traditional units of our country are disappearing under the pretext of unit unification. Accordingly, we propose that our units should not be neglected in university education, but should be labeled together. The purpose of this study is to raise the necessity of reorganizing the unit conversion between the SI unit system and the traditional life improvement unit, which continues to be the convenience of life, and applying it in university physics education to enable the conversion with our traditional unit, and to educate the importance of the meaning and function of our traditional unit.

Performance of Column Type Bioreactor Packed with Immobilized Cyclodextrin Glucanotransferase for Cyclodextrin Production

  • Lee, Yong-Hyun;Lee, Sang-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1991
  • Performance of column type bioreactor packed with immobilized cyclodextrin glucanotransferase (CGTase) on chitosan and Amberite IRA 900 was evaluated for cyclodextrin(CD) production. For CGTase immobilized on chitosan, the maximum CD conversion yield of 42% was achieved at the range of 88-168 units of immobilizied CGTase per gram of chitosan, retention time of 0.3 hr, and from 5.0% (w/v) of partially cyclized soluble starch. On the other hand, for CGTase immobilized on Amberite IRA 900, the maximum conversion yield of 40% was obtained at the range of 3.6-11.0 units of immobilized CGTase per gram of carrier and retention time of 1.2 hr from 5.0% of substrate. Above CD conversion yields are almost identical level with that can be obtained with soluble CGTase of 47%. The productivities of bioreactor packed with immobilized CGTase were 17.0g of CD/lㆍhr for amberite IRA 900 and 15.5g of CD/lㆍhr for chitosan. The partially cyclized starch with soluble CGTase were more suitable as substrate to achieve better CD conversion yield, and 5% (w/v) of partially cyclized soluble starch containing 10% (w/w) of CD was found to be most suitable to obtain maximum CD conversion yield.

  • PDF

A New Method of Yielding the GDP of Korea Small Business: Conversion of the Statistics of Workplace Units to Industrial Units (중소 서비스 기업 부가가치 산출을 위한 새로운 방법: 사업체 통계를 기업체 통계로 전환)

  • Jeong, Hyeong-Chul;Chung, Yeon-Seung
    • The Korean Journal of Applied Statistics
    • /
    • v.20 no.1
    • /
    • pp.11-22
    • /
    • 2007
  • In this study, we have proposed the new statistical methods to convert the statistics based of workplace units into the statistics based of industrial units using the industrial survey data published by National Statistical Once in 2001. It could help to apprehend the weight of service sectors of korea small business in terms of the Gross Domestic Product (GDP).

A Historical Study of Non-standard Weight and Measuring Units (역대(歷代) 약물(藥物) 비표준(非標準) 계량단위(計量單位)의 고찰(考察))

  • Yun, Sung-Joong;Moon, Young-Choon;Kim, Ji-Hoon;Jung, Gi-Eun;Kim, Yun-Kyung
    • Herbal Formula Science
    • /
    • v.24 no.4
    • /
    • pp.335-351
    • /
    • 2016
  • Objective : This study was done to clarify ambiguous non-standard weight and measuring units in medical classics. Methods : Using medical classics and research dissertations, we studied the basic definitions of weight and measuring units and the types of non-standard weight and measuring units. We compared non-standard weight and measuring units in the reference literatures, to determine the dose of herbs in the prescriptions. Results : There are three types of units in non-standard weight and measuring units. These are 'Quantity measuring unit', 'Resembrance measuring unit', and 'Eye measuring unit'. And we found historical efforts and progresses for proper ways to convert non-standard weight and measuring units to standard weight and measuring units. Conclusions : This research will be the basic data for the standardization of prescriptions. Additional study was still required for precise weighing and measuring in Korean medicine and pharmacy.

A study of AC-DC PFC ZVS Interleaved Boost Converter (AC-DC PFC ZVS 인터리브 승압형 컨버터에 관한 연구)

  • Lee, Sung-Ho;Kim, Yong;Seo, Sang-Hwa;Kwon, Soon-Do;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1224-1225
    • /
    • 2011
  • This paper proposes a novel soft-switching interleaved boost converter composed of two shunted elementary PFC boost conversion units and an auxiliary inductor. This converter is able to turn on both the active power switches at zero voltage to reduce their switching losses and evidently raise the conversion efficiency and power factor. Since the two parallel-operated elementary boost units are identical, operation analysis and design for the converter module becomes quite simple. A laboratory test circuit is built, and the circuit operation shows satisfactory agreement with the theoretical analysis. The performance of the proposed PFC rectifier was evaluated on an experimental 300[W] PFC prototype.

  • PDF

Implementation of IQ/IDCT in H.264/AVC Decoder Using GP-GPU (GP-GPU를 이용한 H.264/AVC 디코더의 IQ/IDCT구현)

  • Jeong, Jun-Mo;Lee, Kwang-Yeob
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.76-81
    • /
    • 2010
  • The need for dedicated hardware continue to decrease as the mobile CPU's performance increases. But, there is a limit to a mobile CPU's performance. GP-GPU(General-Purpose computing on Graphics Processing Units) can improve performance without adding other dedicated hardware. This paper presents the implementation of Inverse Quantization, Inverse DCT and Color Space Conversion module in H.264/AVC decoder using GP-GPU for a mobile environments. The proposed architecture improves approximately 40% of performance when it use all the features.

Development of a Resource-based Relative Value Scale and Its Conversion Factor for Advanced Nursing Practices in the National Health Insurance (중환자 전문간호행위에 대한 건강보험 상대가치 및 환산지수 개발)

  • Kim, Jin-Hyun;Kim, Myung-Ae;Kim, Mi-Won;Kim, Kyung-Sook;Yoo, Cheong-Suk
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.3
    • /
    • pp.302-312
    • /
    • 2011
  • Purpose: The purpose of this study was to develop a resource-based relative value scale (RBRVS) and its conversion factor for advanced nursing practices carried out by critical care nurse practitioners (CCNP) in intensive care units. Methods: The methodology was developed by calculating CCNP's RBRVS for 32 advanced nursing services based on CCNP's workload and time spent in the context of national health insurance. A cost analysis was performed to estimate the conversion factor of CCNP's RBRVS. The share of CCNP's contribution to fee-for-service in intensive care units was also analyzed. Results: Calculation of the RBRVS of 32 advanced nursing practices showed a range of points from 100.0 to 1,181.4 and an average of 296.1 points. The relevant conversion factor for advanced nursing practices in CCNP were estimated at 37.3-48.4 won. The contribution rate of CCNP's advanced nursing practices in the relative value scale of the national health insurance was estimated at 0.1-31.3%. Conclusion: Measuring the economic value of advanced nursing services will be a basis for esta-blishing a reimbursement system for CCNP's practices and thus encourage a social demand for advanced nurse practitioners.