• 제목/요약/키워드: conventional procedure

검색결과 1,560건 처리시간 0.024초

Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

  • Al-Fouzan, Afnan F.;Al-mejrad, Lamya A.;Albarrag, Ahmed M.
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.402-408
    • /
    • 2017
  • PURPOSE. The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION. The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

개선된 드릴 디자인을 적용한 간소화된 드릴링 과정에 관한 연구 (A study on simplified procedure of enhanced designed implant drill)

  • 윤지훈;전계록;윤미정;허중보;정창모
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.368-376
    • /
    • 2015
  • Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.

개량된 McIndoe 술식을 이용한 무질증 환자의 질 재건 (A Modified McIndoe Operation for Treatment of Vaginal Agenesis)

  • 탁관철;최봉균;최종우
    • Archives of Plastic Surgery
    • /
    • 제32권1호
    • /
    • pp.117-123
    • /
    • 2005
  • The reconstructive modalities for vaginal reconstruction include simple dilatation, skin graft, use of intestinal segments and various methods using flaps. However, skin grafting procedure is the most commonly used technique and the McIndoe procedure is a representative technique among skin grafting procedures. McIndoe procedure is easier, faster and has a lower morbidity compared to other techniques. However the conventional McIndoe procedure has several problems such as incomplete vestibule formation, excessive bleeding during dissection, possibility of recto-vaginal or urethro-vaginal fistula formation, late vaginal contracture and discomfort in wearing hard plastic mold for a long time after operation. To solve these problems, the authors modified the conventional McIndoe procedure in several perspectives. The undeveloped vestibule was incised with X-shaped mucosal incision between the urethral opening and posterior margin of the vestibule and deepened by blunt finger dissection to provide a sufficient diameter & length of the neovagina and to minimize bleeding. A sizable medium thickness split skin graft was harvested and wrapped over a roll gauze-filled condom mold. Applying multiple stab incision on the skin grafted condom mold, it was inserted into the prepared neovaginal canal. Distal margin of the skin graft was secured with tips of the mucosal flaps created by X-shaped vestibular incision to prevent accidental extrusion of the skin grafted mold. During last 15 years, we applied this modification to 20 vaginal agenesis patients and investigated results of the 12 patients who could be followed up serially including hematoma formation and skin graft survival rate, size, depth, presence of late contracture, appearance, comfortness, and hygiene of the neovagina. And they were compared with 8 patients of 20 patients who underwent conventional McIndoe procedures. The modified McIndoe procedure revealed lower complication rate, higher patient satisfaction and better functional results.

설소대단축증의 수술적 방법에 따른 비교 (A Comparison Study of the Surgical Outcome According to the Surgical Technique)

  • 홍원표;서용석;송미현;양해동;김성수
    • 대한후두음성언어의학회지
    • /
    • 제14권1호
    • /
    • pp.10-15
    • /
    • 2003
  • Background and Objectives : Ankyloglossia, commonly known as tongue-tie, is the result of a short, fibrous lingual frenulum or highly attached geioglossus muscle. This condition may cause sucking and swallowing problems, articulation disorders, interference with the tongue's cleansing action, increased the potential for caries, and inability to lick the lips, play a wind instrument, and 'french kiss' Treatment is surgical procedure. In the most cases, horizontal sectioning and mucosal suture(the conventional procedure) is preferred, but in some cases, the Z-plastic procedure is effective. This study is aimed to compare the result of the two procedures. Materials and Methods : Twenty tongue-tie patients underwent operation. Ten patients were treated with the Z-plastic procedure and ten patients were treated with the conventional method randomly. We checked preoperative mobile tongue length, postoperative mobile tongue length, operation time and postoperative wound states. Results : Among the 20 cases of tongue-tie, 2 cases are excepted due to pre-operative state, thus we compared 18 cases of tongue-tie patients. There is no statistically significant difference between the two procedures except in operation time. The Z-plastic procedure apparently needs a little more operating time. Conclusion : Patients treated with the Z-plastic procedures appeared to have better outcomes, but the data shows no statistical significance except in operating time. Consequently, the Z-plastic procedure is indicated in a limited amount of cases.

  • PDF

Advantages of Scorpion Suture Passer and 70 Degrees Arthroscope in Arthroscopic Bankart Repair: Usefulness for Inferior Labral Repair

  • Hyun, Yoon-Suk;Shin, Woo-Jin
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.201-207
    • /
    • 2017
  • Background: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a $70^{\circ}$ arthroscope in arthroscopic Bankart repair compared to hook typed suture passer. Methods: Scorpion in 19 patients, the hook type suture passer (conventional group) in 18 patients were used. All patients underwent the same procedure except for the type of suture passer used. Another different point of the procedure were telescopes and the number of portals used; three arthroscopic portals (posterior, anterorsuperiorlateral, and mid-anterior) and a $30^{\circ}$ arthroscope in the conventional group, but two portals and a $70^{\circ}$ arthroscope as well as the $30^{\circ}$ one in the Scorpion group. The surgery time and the surgical complications including an iatrogenic axillary nerve injury were recorded. Results: The Scorpion group showed a significant decrease in surgery time compared to the conventional group. In contrast to the conventional group, Scorpion provided an easy estimation of the exit of suture passing, no iatrogenic labral injury during the passing procedure with straight movement and the sharp tip of the knife installed. Iatrogenic supraspinatus injuries could be avoided when making an accessory anteosuperiorlateral portal due to the $70^{\circ}$ arthroscope. Conclusions: In arthroscopic Bankart repair, the use of the Scorpion suture passer and a $70^{\circ}$ arthroscope can reduce the surgery time, avoid unnecessary supraspinatus injury, and avoid iatrogenic axillary nerve damage through the relatively easy and precise suture passing and saving of the anterosuperior portal.

Eversion Carotid Endarterectomy : A Short Review

  • Davidovic, Lazar B.;Tomic, Ivan Z.
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권3호
    • /
    • pp.373-379
    • /
    • 2020
  • Carotid endarterectomy (CEA) is the main procedure in carotid surgery, as well as the most frequent vascular procedure. Two techniques of CEA are available : eversion and conventional plus patch angioplasty. Eversion CEA is anatomic procedure that reduces ischemic and total operative time. Simultaneous correction of the joined carotid kinking and coiling is possible, easy and safe, while the usage of patch is excluded. Thanks to oblique shape of anastomosis, eversion CEA is associated with low risk of long-term restenosis. The false anastomotic aneurysms occurrence is very rare, almost impossible after eversion CEA. However, the usage of carotid shunt during eversion CEA is not always simple, while proximal or distal extension of the carotid plaque can make eversion CEA more difficult and risky. Eversion CEA should be the first choice in carotid surgery. Conventional CEA is indicated in cases when carotid plaque is extended more than usual, as well as, if the usage of carotid shunt is necessary.

접합부 표준화 데이터베이스를 활용한 전단접합 설계 프로세스 개선 (Improvement of Shear Connection Design Procedure using Connections Standardization Database)

  • 김희동;황인규;이명재
    • 한국강구조학회 논문집
    • /
    • 제26권2호
    • /
    • pp.81-89
    • /
    • 2014
  • 국내에서 진행되는 전단 접합부 상세 설계 프로세스를 고찰한 결과 구조 설계자와 제작도면 작성자 및 제작자간의 상호 정보 교류에 많은 문제점이 있으며, 작업 진행상에서도 불필요한 업무들이 존재하는 것으로 파악되었다. 이에 본 연구에서는 이러한 접합부 상세 설계시 문제점을 개선하기 위해 구조설계자가 접합부 구조설계부터 최종 도면화 작업까지를 일괄적으로 관리할 수 있는 개선된 설계프로세스를 제안하였으며, 이를 위해 강구조건축 접합부 표준상세 지짐의 내용을 활용하여 접합부 설계에 표준화 및 전산화를 도입할 수 있도록 하였다. 이를 통하여 구조적 안전성과 제작 및 시공성이 확보된 접합상세를 효율적으로 설계 및 도면화 할 수 있으며 기존 설계 프로세스에서 야기될 수 있는 문제점을 근본적으로 차단할 수 있었다.

STRAIN CHANGES OF ACRYLIC RESIN SPECIMENS CURED BY THREE CURING CYCLES

  • Kang, In-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.236-245
    • /
    • 2002
  • The acrylic resin was first introduced as denture base materials in 1937 and it is commonly used for denture base fabrication nowadays. Three different curing cycles (Conventional curing cycle, short curing cycle and long curing cycle) and three commercially available heat-activated acrylic resins (Vertex RS, Lucitone 199 and ProBase Hot) were investigated to find the curing cycle and material that showed the minimum shrinkage of the resin during polymerization process. A brass master mold was fabricated and duplicated by additional silicone impression material. Stone molds were made by pouring of type III dental stone (SILKY-ROCK YELLOW, Whip-Mix, Louisville, Kentucky). It was embedded in the flask. Strain gauge and thermocouple were embedded in the specimen. Strain gauge and thermocouple were connected to signal conditioning amplifier and data was recorded by pre-programmed software. The parameters ESmax (Maximum expansion strain), Sb (Strain measured just before deflasking procedure), Sa (Strain measured just after deflasking procedure) and Sf (Strain measured at the end of the experiment) were measured. ${\Delta}$S was calculated from Sb and Sa (${\Delta}$S=Sb-Sa). In the experiment concerned about materials, the parameters 90-ESmax (Maximum expansion strain measured during early 90 minutes of curing procedure), 180-ESmax (Maximum expansion strain measured from 90 minutes to 180 minutes), Sb, Sa, ${\Delta}$S and Sf were measured and the following conclusions were made. 1. The ESmax value of conventional curing cycle showed the largest value and the 180-ESmax value of Lucitone 199 showed the smallest value. 90-ESmax values showed no significant difference (p<0.05). 2. ${\Delta}$S values of conventional curing cycle showed the positive values. ${\Delta}$S values of short curing cycle and long curing cycle showed the negative values. All three materials cured by conventional curing cycle showed the positive values. 3. The Sf values of long curing cycle and ProBase Hot (cured by conventional curing cycle) showed the smallest values.

Fundamental and conventional computer simulation for the stability of non-uniform systems

  • Wang, Chunping;Chen, Keming
    • Advances in nano research
    • /
    • 제13권2호
    • /
    • pp.135-146
    • /
    • 2022
  • The accurate assessment of the performance of nonuniform systems requires a thorough understanding of stability analysis. As a result, the theoretical modeling of the influence of various variables on the performance of small-scale nonuniform structures with conventional and non-conventional geometries is presented in this paper. According to the fundamental computer simulation based on mathematical and mechanical principles, the stability of the nonuniform structures is examined. Thus, a numerical procedure is used to simulate the stability and instability characteristics of the nonuniform small-scale structures via computer aid. Theoretic simulation methods provide a great deal of the design and production of small-scale structures at a low cost compared to experimental simulations. Thus, this paper provides a good presentation of the stability analysis of the nonuniform nanoscale structures with high accuracy without actual experimental.

A Distributed Task Assignment Method and its Performance

  • Kim, Kap-Hwan
    • Management Science and Financial Engineering
    • /
    • 제2권1호
    • /
    • pp.19-51
    • /
    • 1996
  • We suggest a distributed framework for task assignment in the computer-controlled shop floor where each of the resource agents and part agents acts like an independent profit maker. The job allocation problem is formulated as a linear programming problem. The LP formulation is analyzed to provide a rationale for the distributed task assignment procedure. We suggest an auction based negotiation procedure including a price-based bid construction and a price revising mechanism. The performance of the suggested procedure is compared with those of an LP formulation and conventional dispatching procedures by simulation experiments.

  • PDF