• Title/Summary/Keyword: conventional medicine

Search Result 2,758, Processing Time 0.035 seconds

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

Development of Odor-Reduced Korean Traditional Cheonggukjang Added with Job's Tears (냄새저감형 율무청국장 제조에 관한 연구)

  • Park, Ju-Hun;Han, Chan-Kyu;Choi, Sook-Hyun;Lee, Bog-Hieu;Lee, Hye-Jeong;Kim, Sung-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.2
    • /
    • pp.259-266
    • /
    • 2011
  • This study was performed to develop an odor-reduced Korean traditional Cheonggukjang (fermented soybean paste) by adding Job's tears to Cheonggukjang made with soybean (control) only. The study included the determination of best addition percentage of Job's tears versus soybean, sensory evaluation, and aroma patterns and its components as well as proximate composition analyses of Cheonggukjang. Job's tears Cheonggukjang (CAJT) was prepared by inoculating Bacillus subtilis and fermented at $40^{\circ}C$ for 48 hours. Ratios of soybean : Job's tears for Job's tears Cheonggukjang were 1:1, 2:1, 3:1, and 4:1, respectively. In comparison of proximal composition, Job's tears Cheonggukjang was high in moisture and carbohydrates, but low in calorie, fat, protein, ash and amino nitrogen. The pH of CAJT was lower than those of control and conventional Cheonggukjang (CC) sold in the market, and the acidity was the lowest in CC. The color of Job's tears Cheonggukjang appeared the whiter and more yellowish, but less reddish in proportion to contents of Job's tears. The contents of viscous substances were higher in CAJT compared with those of control and CC. The contents of glutamic acid, the major components of viscous substances were lower in CAJT than in control and CC, and the contents of fructose higher in CAJT. The scores of sensory evaluation were the highest in Job's tears Cheonggukjang mixed with soybean : Job's tears=4:1. The aroma pattern of CC analyzed was conspicuously dissimilar to the control and CAJT and also discriminated by electronic nose examination. The pyrazines, volatile compounds peculiar to Cheonggukjang, were found to be lower in CAJT by SPME-GC/MS assay. Additionally, the acetic acid, butanoic acid, and naphthalene causing off-flavor were identified in CC, but not in Job's tears Cheonggukjang. The strength of odor through sensory evaluation was by far the lowest in CAJT among the groups. From the findings, it had shown that Job's tears Cheonggukjang would be produced successfully when the ratio of 4:1 (soybean : Job's tears) is employed. Also, it was proved that appropriate ratio of Job's tears addition makes Cheonggukjang odor-reduced and well accepted by people.

Usefulness of Dual-Echo in Steady State (DESS) Image in Chondromalacia of Knee Joint: Comparison of DESS and Turbo Spin-Echo MR Images (슬관절 연골 연화증의 진단에서의 Dual Echo in Steady State (DESS) 영상의 유용성 : 급속 스핀에코 자기공명 영상과 비교)

  • 윤삼현;하두회
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • Purpose : To evaluate the usefulness of Dual Echo in Steady State(DESS) image in the diagnosis of chondromalacia of the knee compared with turbo spin-echo MR images Materials and Methods : We included 26 patients with chondromalacia of the knee. MR imaging was obtained with a 1.5T imager. Sagittal and coronal double echo T2 weighted images(TR/TE 3000-4200/16-96msec, FOV $140-160{\times}140-160mm$, matrix size $180{\times}256$, slice thickness 4.0mm, interslice gap 0.5mm), and sagittal DESS image(TR/TE 25.4/9.0msec, flip angle $35-45^{\circ}$, FOV $150-160{\times}150-160mm,{\;}matrix{\;}size{\;}192{\times}256$, effective slice thickness 1.5mm) were obtained. Cartilage lesions were staged according to a modified scheme proposed by Outerbirdge: grade 0, normal; grade 1, softening or/and swelling; grade 2, mild surface fibrillation or/and less than 50% of cartilage thickness; grade 3, severe surface fibrillation or/and loss of more than 50% of cartilage thickness but without exposure of subchondral bone; and grade 4, complete loss of cartilage with subchondral bone exposure. Gradings were determined by two readers with consensus, and patellofemoral, medial and lateral tibiofemoral compartments were evaluated. Results : Arthroscopic findings revealed grade 1 in seven cases, grade 2 in 21 cases, grade 3 in six cases, and grade 4 in 18 cases. Sensitivity of turbo spin-echo MR image was as follows; 0%, 14%, 0%, 61% in each grade, and sensitivity of DESS image was as follows; 0%, 33%, 50%, 67%, in each grade(p=0.001). In the detection of chondromalacic lesions regardless of gradings, sensitivity, specificity and accuracy of conventional MR image were 59.6% 88.6% 78.8%, and of DESS image, 73.1% 88.4%, 82.2%(p=0.007). Conclusion : For chondromalacia of knee joints, DESS images showed higher sensitivity than turbo spin-echo MR images. Therefore, DESS images will be helpful for diagnosis of chondromalacia of knee joints.

  • PDF

A Survey on the Foodservice Management Practices at Child Care Centers in Gyeonggi Area (경기 지역 영유아 보육시설의 급식운영관리 실태 조사)

  • Sohn, Chun-Young;Pak, Hee-Ok
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.4
    • /
    • pp.577-586
    • /
    • 2011
  • This study was carried out to investigate food service management practices in various operation types of child care center in Gyeonggi area of Korea, and to provide basic information for improving food service management policies at child care centers. Self-administrated questionnaires were collected from 102 child care center directors. The statistical analysis was completed using SPSS ver. 18.0 program. Approximately 97.1% of the directors were women. The number of total children were difference in public, private and home care centers respectively (p<0.001), and time of operation was significantly (p<0.01). Only 8.9% of the centers employed a dietitian, whereas 92.5% of the centers employed cook or assistant cook, thus food service was not managed by professionals in most centers. All of the centers had been self-operated and meals were prepared in a conventional manner. In approximately 89.2% of the centers servings snacks twice a day. Menu planner of the centers which have no dietitian was the child care information center (47.5%) or the director (34.7%). In most centers, the directors was also purchasing manager and 36.0% of the center purchased food every day. These results indicated that food service management guidelines need to be established by the child care center type with the government control and financial support. We recommended that they furnish the efficient food service program for food service management.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF

Diffusion-Weighted MR Imaging of the Brain Tumors: The Clinical Usefulness (두개강내 종양의 확산강조자기공명영상: 임상적 유용성)

  • 이영철;서정진;정광우;강형근;김윤현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.34-41
    • /
    • 2000
  • Purpose: To evaluate the clinical usefulness of diffusion weighted MR imaging(DWI) in the differential diagnosis of brain tumors. Materials and methods: DWI and conventional MR images of nineteen patients with brain tumors(10 metastatic tumors, 4 high grade gliomas, 4 low grade astrocytomas, one oligodendroglioma)were obtained on 1.5T unit. DWI was obtained using single shot spin echo planar imaging with b-value near 1000. We analyzed the signal intensities of lesions including solid portion, necrotic or cystic portion and peritumoral edema of brain tumors (classified five grades comparison with the signal intensities of brain parenchyma and CSF)and calculate the SIR(signal intensity ratio)of lesions to the contralateral normal brain parenchyma. We analyzed statistically the signal intensities and SIR of tumors using independence T test. Results: In solid portions of tumors, all the metastatic tumors and high grade gliomas showed high signal intensities, but low grade astrocytomas and oligodendroglioma showed iso or slight high signal intensities to the normal brain parenchyma. The SIR of solid portion has positive correlation with malignant pot ential(metastatic tumors 1.52, high grade gliomas 1.38, low grade astrocytomas 1.16, oligodendroglioma 1.31)(p < 0.05). In peritumoral edema where seen in 14 tumors, seven of 10 metastatic tumors and two of 4 high grade gliomas showed iso signal intensities, whereas edemas in other 5 brain tumors showed hyperintense to the normal brain parenchyma. The SIRs of peritumoral edemas in metastatic tumors (1.14) was lower than high grade gliomas(1.31),but statistically insignificant. The SIR of cystic or necrotic portion of brain tumors was 0.63. In non enhancing solid portions, three of six cases showed hyperintense to the adjacent peritumoral edema. Conclusion: On DWI, the signal intensities of solid portion has positive correlation with malignant potential, and perilesional edema of brain tumors appear various signal intensities owing to "T2 shine through effect" and the extensiveness of vasogenic edema. Another merit using DWI on the evaluation of brain tumors is to improved better delineation of tumor margins from the adjacent edemas, especially at the non enhancing solid portion of the tumors.

  • PDF

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF