• Title/Summary/Keyword: convection coefficient

검색결과 255건 처리시간 0.022초

EFFECTS OF SORET AND DUFOUR ON NATURAL CONVECTIVE FLUID FLOW PAST A VERTICAL PLATE EMBEDDED IN POROUS MEDIUM IN PRESENCE OF THERMAL RADIATION VIA FEM

  • RAJU, R. SRINIVASA
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권4호
    • /
    • pp.309-332
    • /
    • 2016
  • Finite element method has been applied to solve the fundamental governing equations of natural convective, electrically conducting, incompressible fluid flow past an infinite vertical plate surrounded by porous medium in presence of thermal radiation, viscous dissipation, Soret and Dufour effects. In this research work, the results of coupled partial differential equations are found numerically by applying finite element technique. The sway of significant parameters such as Soret number, Dufour number, Grashof number for heat and mass transfer, Magnetic field parameter, Thermal radiation parameter, Permeability parameter on velocity, temperature and concentration evaluations in the boundary layer region are examined in detail and the results are shown in graphically. Furthermore, the effect of these parameters on local skin friction coefficient, local Nusselt number and Sherwood numbers is also investigated. A very good agreement is noticed between the present results and previous published works in some limiting cases.

인공심장판막의 현황

  • 김형묵
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.94-96
    • /
    • 1989
  • Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained.

  • PDF

GIS 모선의 온도상승 예측을 위한 해석적 방법과 Flux2D의 결합 (Coupling of Flux2D and Analytic Method for Temperature Rise Prediction of Busbar Part of EHV GIS)

  • 김현훈;김정철;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 1999
  • In order to design the current carrying conductor for GIS, it is important to predict temperature-rise when rated current flows. This paper deals with the coupling of Flux2D and analytic method to calculate the heat transfer coefficient. Heat transfer by conduction and convection is considered between the current carrying conductor and $SF_6$ gas. The result shows reasonable temperature distribution.

  • PDF

매끈한 튜브의 입구 영역에서 난류유동에 의한 대류와 비회복사 (Non-gray Radiation with Turbulent Convection in the Entrance Region of a Smooth Tube)

  • 서태범
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.667-680
    • /
    • 1995
  • 튜브 내의 입구영역에서 난류 유동에 의한 대류와 비회복사(non-gray radiation)가 동시에 일어날 때의 열전달특성을 수치해석적으로 연구하였다. 작동유체는 이산화탄소, 수증기, 질소의 혼합가스라고 가정하였다. 지배방정식을 계산하기 위해 유한차분법이 이용되었고, 복사전달방정식을 이차편미분방정식으로 바꾸기 위해 P-1 근사법이 사용되었다. 그리고 혼합가스의 비회흡수계수(non-gray absorption coefficient)는 지수광폭밴드모형(exponential wide band model)을 이용해서 구하였다. 열전달특성에 대한 온도조건의 영향을 조사하기 위해 튜브의 축방향에 대한 평균 온도와 뉴셀트수(Nusselt number)의 변화를 몇 가지 다른 온도조건에 대해 나타내었다. 또한, 가스의 성분조성에 대한 영향을 조사하였으며, 이러한 결과에 기초해서 튜브 내에서 난류유동에 의한 대류와 비화복사가 동시에 일어날 때의 복사 뉴셀트수를 쉽게 예측할 수 있는 방법을 제시하였다.

  • PDF

공냉식 수직 흡수기의 열전달에 미치는 계면활성제의 영향 (Influence of surfactant on heat transfer of air-cooled vertical absorber)

  • 윤정인;권오경;문춘근
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.740-748
    • /
    • 1999
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare inner surface, groove inner surface, corrugated inner surface and spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of film Reynolds number in the range of 20~200. Experiments were tarried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.

  • PDF

고효율 나노절연유 제조 및 변압기에의 적용 (Preparation of High-Efficient Oil-based Nanofluids and It's Application to the Transformer)

  • 유현성;최철;오제명
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.31-32
    • /
    • 2007
  • Oil-based nanofluids are prepared by dispersing spherical and fiber-shaped $Al_2O_3$ and AlN nanoparticles in transformer oil. Two hydrophobic surface modification processes are compared in this investigation. It is obvious that the combination of nanoparticle, surfactant and surface modification process is very important for the dispersity of nanofluids. For ($Al_2O_3$+AIN) particles with 1% volume fraction, the enhancement of thermal conductivity and convective heat transfer coefficient is nearly 11% and 30%, respectively, compared to pure transformer oil. The cooling effect of ($Al_2O_3$+AlN)-oil nanofluids on the heating element and oil itself is confirmed by a natural convection test using a prototype transformer.

  • PDF

An Experimental Study on Air-side Performance of Fin-and-Tube Heat Exchangers with Slit Fin

  • Chang, Keun-Sun;Phan, Thanh-Long
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.627-632
    • /
    • 2006
  • An experimental study is conducted to investigate the effect of the tube row and fin spacing on the air-side heat transfer and friction characteristics of fin-tube heat exchangers with slit fin pattern. A total of twelve samples of fin-tube heat exchangers with the nominal tube diameter of 7 mm, transverse tube pitch of 19 mm and longitudinal tube pitch of 12.5 mm are tested. The thermal fluid measurements are made using a psychometric calorimeter. The raw data are reduced to the desired heat transfer coefficient in terms of j-factor and friction factor of f for various frontal air velocities, fin pitches and number of tube rows.

  • PDF

INFLUENCE OF HALL CURRENT AND HEAT SOURCE ON MHD FLOW OF A ROTATING FLUID IN A PARALLEL POROUS PLATE CHANNEL

  • VENKATESWARLU, M.;UPENDER REDDY, G.;VENKATA LAKSHMI, D.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제22권4호
    • /
    • pp.217-239
    • /
    • 2018
  • This paper examined the MHD and thermal behavior of unsteady mixed convection flow of a rotating fluid in a porous parallel plate channel in the presence of Hall current and heat source. The exact solutions of the concentration, energy and momentum equations are obtained. The influence of each governing parameter on non dimensional velocity, temperature, concentration, skin friction coefficient, rate of heat transfer and rate of mass transfer at the porous parallel plate channel surfaces is discussed. During the course of numerical computation, it is observed that as Hall current parameter and Soret number at the porous channel surfaces increases, the primary and secondary velocity profiles are increases while the primary and secondary skin friction coefficients are increases at the cold wall and decreases at the heated wall. In particular, it is noticed that a reverse trend in case of heat source parameter.

냉동냉장고의 실내위치에 따른 에너지 소비량의 변화에 관한 연구 (Consideration of Energy Consumption with Respect to the Position of Refrigerator in a Room)

  • 남평우;이재헌;박만흥;김석현
    • 대한설비공학회지:설비저널
    • /
    • 제14권3호
    • /
    • pp.200-211
    • /
    • 1985
  • The paper discusses the problem of the reduction in Coefficient of Performance (COP) in a refrigerator due to the inadequate position or some flow obstacles such as shelves in a room. The propriety of the present numerical method has teen proved by experiments using the flow visualization technique. The COP are calculated from the temperature rise of the condenser whose temperature indicates the condensing temperature of refrigerant The temperature rise is predicted by the theory of the steady two-dimensional laminar natural convection. In a room size of $2m\;{\times}\;2m$ the COP are decreased by 0.3 when the gap between the wall and condenser are decreased from 10cm to 2cm. While the COP are decreased by 0.55 as the shelf length increases from 0 to 75cm.

  • PDF

Design of A scale-down experimental model for SFR reactor vault cooling system performance analyses

  • Kim, Koung Moon;Hwang, Ji-Hwan;Wongwises, Somchai;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1611-1625
    • /
    • 2020
  • We propose a scaled-down experimental model of vertical air-natural convection channels by applying the modified Ishii-Kataoka scaling method with the assistance of numerical analyses to the Reactor Vault Cooling System (RVCS) of the Proto-type Gen-IV Sodium-cooled fast reactor (PGSFR) being developed in Korea. Two major non-dimensional numbers (modified Richardson and Friction number) from the momentum equation and Stanton number from the energy balance equation were identified to design the scaled-down experimental model to assimilate thermal-hydraulic behaviors of the natural convective air-cooling channel of RVCS. The ratios of the design parameters in the PGSFR RVCS between the prototype and the scaled-down model were determined by setting Richardson and Stanton number to be unity. The friction number which cannot be determined by the Ishii-Kataoka method was estimated by numerical analyses using the MARS-KS system code. The numerical analyses showed that the friction number with the form loss coefficient of 2.0 in the scale-down model would result in an acceptable prediction of the thermal-hydraulic behavior in RVCS. We also performed experimental benchmarking using the scaled-down model with the MARS-KS simulations to verify the appropriateness of the scale-down model, which demonstrated that the temperature rises and the average air flow velocity measured in the scale-down model.