• Title/Summary/Keyword: control threshold

Search Result 1,145, Processing Time 0.027 seconds

Flow Control with Hysteresis effect in ATM Network (ATM망의 히스테리시스 특성을 이용한 흐름제어기법)

  • 정상국;진용옥
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.9
    • /
    • pp.10-17
    • /
    • 1994
  • In this paper, a priority schedling and a flow control algorithm with hysteresis effect are proposed for high-speed networks. A mathematical model for the flow control is proposed and a cell transition probability from this model is found. And the performance of the proposed algorithm is analyzed by a computer simulation. According to the simulation results, it can be shown that the priority scheduling and the flow control with hysteresis effect get the cell loss probability 0.061 better and the average delay 100ms better and the average delay 100ms beter than those of single threshold.

  • PDF

Hearing Threshold Shift Level of Weavers on Wearing the Ear Plugs (이전장용여부(耳栓裝用與否)에 따른 난청도(難聽度)의 추이(推移))

  • Kim, Yeong-Hwan;Lee, Jong-Young;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.57-63
    • /
    • 1984
  • To assess the hearing conservation by the hearing protection devices in the field, 1,237 healthy female weavers of 16 to 24 year old were surveyed from April 1982 to January 1983. By reviewing the charts, their working durations, hearing threshold shift levels and whether wearing the ear plugs or not were checked. The hearing threshold levels were measured at 4,000Hz by audiometry AA-30A, RION Japan. They were divided into two groups: an experimental group with ear plug and the control group without it. The threshold shift level above 40dB in controls was 44.6% in left and 40.9% in right ear and that in experimental group 8.0% in left and 6.6% in right ear. The distribution of threshold shift levels between control and experimental group was significantly different in both ears, but that between left and right ear not significantly different in both groups. The longer the working durations were, the more the proportion of high threshold shift levels was and the larger the differences in the proportion of above 40dB between both groups were.

  • PDF

Current perception threshold in diabetic sensory polyneuropathy with normal routine nerve conduction study

  • Park, Kyung Seok;Kwon, Yong Chul;Youn, Minjung;Park, Yong-Shik;Hong, Yoon-Ho;Sung, Jung-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.125-130
    • /
    • 2017
  • Background: Routine nerve conduction study (NCS) can only be used to evaluate the function of large fibers, and the results of NCS are often normal in patients with distal sensory polyneuropathy. The measurement of the current perception threshold (CPT) has been reported to represent a variety of peripheral nerve fiber functions. This study was performed to investigate the value of measuring CPT in patients with diabetic sensory polyneuropathy who have no abnormalities in routine NCS. Methods: Twenty-seven diabetic patients with sensory polyneuropathy and normal routine NCS and 18 age-matched control subjects participated in this study. The CPT was measured on the unilateral index finger and great toe of each subject at frequencies of 5 Hz, 250 Hz, and 2,000 Hz. Results: CPT values were significantly higher in the patient group than in the control group, especially with stimuli at the lowest frequency of 5 Hz (p < 0.05). There were significant correlations between the CPT values obtained at three different frequencies in the patient group, whereas the correlation was only significant in the pair of 250 Hz/5 Hz (both in the hands and feet), and in the pair of 2,000 Hz/250 Hz (in the feet) for the control group. Conclusions: Our data suggest that the CPT test, especially at a stimuli frequency of 5 Hz, may be a useful screening tool for diabetic polyneuropathy in patients who show no abnormalities in routine NCS.

The Performance Improvement of a Linear CCD Sensor Using an Automatic Threshold Control Algorithm for Displacement Measurement

  • Shin, Myung-Kwan;Choi, Kyo-Soon;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1417-1422
    • /
    • 2005
  • Among the sensors mainly used for displacement measurement, there are a linear CCD(Charge Coupled Device) and a PSD(Position Sensitive Detector) as a non-contact type. Their structures are different very much, which means that the signal processing of both sensors should be applied in the different ways. Most of the displacement measurement systems to get the 3-D shape profile of an object using a linear CCD are a computer-based system. It means that all of algorithms and mathematical operations are performed through a computer program to measure the displacement. However, in this paper, the developed system has microprocessor and other digital components that make the system measure the displacement of an object without a computer. The thing different from the previous system is that AVR microprocessor and FPGA(Field Programmable Gate Array) technology, and a comparator is used to play the role of an A/D(Analog to Digital) converter. Furthermore, an ATC(Automatic Threshold Control) algorithm is applied to find the highest pixel data that has the real displacement information. According to the size of the light circle incident on the surface of the CCD, the threshold value to remove the noise and useless data is changed by the operation of AVR microprocessor. The total system consists of FPGA, AVR microprocessor, and the comparator. The developed system has the improvement and shows the better performance than the system not using the ATC algorithm for displacement measurement.

  • PDF

Effects of Pre-eccentric Exercise on Exercise Induced Muscle Damage (사전 원심성 운동이 운동 유발 근 손상에 미치는 효과)

  • Kim, Byoung-Ju;Lim, Young-Eun;Yoon, Se-Won;Park, Seung-Kyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: This study examined the effects of pre-eccentric exercise to the quadriceps for the prevention of delayed onset muscle soreness (DOMS) and recovery of muscular function, depending on the training intensities. Methods: Subjects were divided into one of three groups that control group, a low intensity eccentric exercise group (LIEE group) and a high intensity eccentric exercise group (HIEE group). Subjects who underwent pre-eccentric exercise undertook exercise at an intensity of 25% and 75% of maximal voluntary contractions, respectively. After undertaking pre-eccentric exercise for eight weeks, eccentric exercise was applied again to induce DOMS. Measurements were conducted to examine pain and muscular function changes before, immediately after, after the induction of DOMS, and at the first, third, fifth and seventh days after the induction of DOMS. Results: Subjects who underwent pre-eccentric exercise showed a significant difference from the control group for the changes in the visual analogue scale (VAS) pain threshold, pressure pain threshold and muscle thickness by isometric contraction from measuring DOMS, and in particular, pain threshold by isometric contraction had remarkable effect in the LIEE group of subjects. For the change of the root mean square values using mechanomyography (MMG) as the measurement of muscular function recovery, subjects who had undertaken pre-eccentric exercise group showed a significant difference as compared to the control group. Conclusion: Pre-eccentric exercise was very effective in preventing and recovering delayed onset muscle soreness and was helpful to prevent and recover from decreased muscular function. The difference based on the intensity of exercise was not great, but it was more effective in the low intensity eccentric exercise group of subjects. Therefore, it can be considered that pre-eccentric exercise has a high application value as a physical therapy intervention for prevention and rehabilitation of sports injuries.

  • PDF

Effects of Sling and Resistance Rotation Exercises on Pelvic Rotation and Pain in Patients with Chronic Low Back Pain

  • Kim, Dae Hyun;Kim, Tea Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.166-172
    • /
    • 2018
  • Purpose: This study compared the different sling and resistance exercises on pelvic rotation during active straight leg raises (ASLR) and on pain in patients with chronic low back pain (CLBP). Methods: Twenty subjects were divided randomly into a sling group (SG) and a resistance exercise group (REG). Internal oblique (IO), external oblique (EO), rectus abdominis (RA), and rectus femoris (RF) muscle activity; pelvic rotation angle during ASLR; and visual analogue scale, pressure pain threshold were measured. Sling and resistance exercises were then performed for 30 minutes and the measurements taken again. Results: Both groups showed significantly lower RF muscle activity and significantly higher EO and IO muscle activity (p<0.05). The RA muscle activity decreased significantly in the SG, but increased significantly in the REG (p<0.05). The pelvic rotation angle was significantly lower in the SG (p<0.05). The pain press threshold increased significantly in both groups (p<0.05). The visual analogue scale decreased significantly in the SG (p<0.05). Conclusion: Both exercises appear to be beneficial for modifying the muscle activity and pain control in the intervention of CLBP. On the other hand, the sling was more effective in increasing the pressure threshold than resistance exercise, and the pelvic rotation angle was reduced. Therefore, both exercises can help patients with CLBP change their muscle activity and control pain. CLBP patients should use a sling for short periods of time to learn to reduce the pain and control pelvic rotation.

A Study on Modified Weighted Filter for Edge Preservation in AWGN Environments (AWGN 환경에서 에지 보존을 위한 변형된 가중치 필터에 관한 연구)

  • Kwon, Se-Ik;Hwang, Yeong-Yeun;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.661-663
    • /
    • 2016
  • Corruption occurs in the process of processing image signal and the corruption changes the pixel value within the image to damage the original information. AWGN(additive white Gaussian noise) is a representative example. For filters to remove AWGN, there are filters such as MF(mean filter), WF(wiener filter), and AWMF(adaptive weighted mean filter). However images processed through standard previous filters lock preservation characteristics in edge areas. Therefore, threshold value is applied for processing on the standard deviation of the local mask in this study and if the standard deviation is smaller than the threshold value, it is not filtered and if the value is bigger than the threshold value, the study suggested an algorithm that processes using weighted value utilizing standard deviation.

  • PDF

ADENOVIRAL VECTOR MEDIATED IN VIVO GENE TRANSFER OF BDNF PROMOTE FUNCTIONAL RECOVERY AFTER FACIAL NERVE CRUSH INJURY (안면신경 압박손상 후 Adenovirus 매개 BDNF 유전자 전달을 통한 신경손상 회복에 관한 연구)

  • Yang, Byoung-Eun;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.308-316
    • /
    • 2006
  • Objectives Despite considerable advances in technique, experience and skill, the precise place of surgery in the treatment of facial nerve injury remains uncertain. We designed a facial nerve crush injury model in rats and evaluated the recovery of crushed nerve which is the most common injury type of facial nerve using adenovirus vector mediated in vivo gene transfer of Brain derived neurotrophic factor(BDNF). Materials and methods In 48 Sprague Dawley rats, we made a facial nerve crush injury model to main trunk before the furcation, and injected a $10^{11}$pfu adenoviral BDNF in experimental group(BDNF adenoviral injection group; ad-BDNF) and $3{\mu}l$ saline in control group(Saline injection group; saline). After a period of regeneration from 10 to 40 days, nerve regeneration was evaluated with functioinal test (vibrissae and ocular movement), electrophysiologic study(threshold, peak voltage, conduction velocity) and histomorphometric study of axon density. Results Vibrissae and ocular movement, threshold and conduction velocity improved as time elapse in both group, however axon density was increased significantly only in experimental group. Functional test in 10 days and 20 days showed no difference between experimental group and control group. Vibrissae movement, threshold, conduction velocity and axon density in 30 days revealed that the regeneration in quality of experimental group was significantly superior to that of control group. Conclusion In general, there is tendency for nerve regeneration in experimental group (BDNF-adenovirus injection group) during 40 days, functional recovery was detected successfully after facial nerve crush in 30 days postoperatively.

The Effects of Regular Pilates Exercise on Blood pressure and Pulmonary Variables (규칙적인 필라테스 운동이 심혈관 및 호흡 변인에 미치는 영향)

  • Lee, Gyu-Chang;Lee, Dong-Yeop;Yu, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3088-3095
    • /
    • 2011
  • The purpose of this study was to investigate the effects of Pilates exercises on the improvement of blood pressure and respiratory function. 36 subjects which were randomly divided into Pilates exercises group(n=18) and control group(n=18). Subjects in the Pilates exercises group were regularly participated in Pilates exercise program for 8 weeks. We were measured the blood pressure and respiratory function such as blood pressure, VO2max, METs, and Anaerobic threshold at before and after the experiment. After 8 weeks, in Pilate exercises group, there were significant improvement on blood pressure and respiratory function except the diastolic blood pressure. And subjects participated in Pilates exercise group were significantly improved compared to control group on systolic blood pressure, VO2max, METs, and Anaerobic threshold. But in control group, there were no significant differences. In conclusion, regular participation in Pilates exercises improved the blood pressure and respiratory function. These results suggest that Pilates exercise is the method that replace aerobic exercise.

The design of the high efficiency DC-DC Converter with Dynamic Threshold MOS switch (Dynamic Threshold MOS 스위치를 사용한 고효율 DC-DC Converter 설계)

  • Ha, Ka-San;Koo, Yong-Seo;Son, Jung-Man;Kwon, Jong-Ki;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.12 no.3
    • /
    • pp.176-183
    • /
    • 2008
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device is proposed in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. DTMOS with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit as a block. The Saw-tooth generator is made to have 1.2 MHz oscillation frequency and full range of output swing from ground to supply voltage(VDD:3.3V). The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device, achieved the high efficiency near 95% at 100mA output current. And DC-DC converter is designed with LDO in stand-by mode which fewer than 1mA for high efficiency.

  • PDF