• 제목/요약/키워드: control parameters

검색결과 9,355건 처리시간 0.037초

견실한 추종 제어를 위한 EHA 시스템의 슬라이딩 모드제어에 관한 연구 (A Study on Sliding Mode Control of EHA System for Robust Control)

  • 박용호;박성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.71-80
    • /
    • 2009
  • The response characteristics of EHA systems are sensitive to the temperature change of working fluid because the temperature of working fluid causes the variation of system parameters such as effective bulk modulus and viscous friction coefficient. In this paper, a precise position control of EHA system using the adaptive sliding mode control system is suggested. The adapted system parameters such as effective bulk modulus and viscous friction coefficient can be used for monitoring failures in the EHA system which has potential applications in the industrial fields. Not only the accuracy of adapted system parameters but also the improved performance and robustness in a given reference position of the cylinder are verified by computer simulation using AMESim software.

자기동조 PID 제어기를 이용한 로보트 매니플레이터의 위치제어 (Position control of robot manipulator using self-turning PID controller)

  • 김유택;이재호;양태규;이상효
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.41-44
    • /
    • 1988
  • This paper represents the study of an effective self-tuning PID control for a robot manipulator to track a reference trajectory in spite of the presence of nonlinearities and parameters uncertainties in robot dynamic models. In this control scheme, an error model of the manipulator is established, for the first time, by difference between joint reference trajectory and tracked trajectory. It's model Parameters are estimated by the recursive least-square identification algorithm, and classical controller parameters are determined by pole placement method. A computer simulation study was conducted to demonstrate performance of the proposed self-tuning PID control in joint-based coordinates for a robot with payload.

  • PDF

An Improved Torque Feed-forward Control with Observer-based Inertia Identification in PMSM Drives

  • Zhao, Shouhua;Chen, Yangcheng;Cui, Lin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.69-76
    • /
    • 2013
  • This paper is concerned with speed tracking control problem for permanent-magnet synchronous drives (PMSM) in the presence of an variable load torque and unknown model parameters. The disturbance of speed control caused by inaccuracy of model parameters has been investigated. A load torque observer has been proposed to observe the load torque and estimate the disturbance caused by inaccuracy of model parameters. Both inertia and friction coefficient are identified in gradient descent approach. The stability condition of the observer has also been studied. Furthermore an improved feed-forward control has been introduced to reduce the speed track error. The proposed control strategy has been verified by both simulation and experimental results.

주파수역 설계를 통한 안정한 일반형 예측제어 (Stable Generalized Predictive Control Using Frequency Domain Design)

  • 윤강섭;이만형
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.58-66
    • /
    • 2001
  • GPC has been reported as a useful self-tuning control algorithm for systems with unknown time-delay and parameters. GPC is easy to understand and implement, and thus has won popularity among many practicing engineers. Despite its success, GPC does not guarantee is nominal stability. So, in this paper, GPC is rederived in frequency domain instead of in the time domain to guarantee its nominal stability. Derivation of GPC in frequency domain involves spectral factorization and Diophantine equation. Frequency domain GPC control law is stable because the zeros of characteristic polynomial are strictly Schur. Recursive least square algorithm is used to identify unknown parameters. To see the effectiveness of the proposed controller, the controller is simulated for a numerical problem that changes in dead-time, in order and in parameters.

  • PDF

유전자 알고리즘을 이용한 제어파라미터 추정모드기반 HFC (Hybrid Fuzzy Controller Based on Control Parameter Estimation Mode Using Genetic Algorithms)

  • 이대근;오성권;장성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2545-2547
    • /
    • 2000
  • In this paper, a hybrid fuzzy controller using genetic algorithm based on parameter estimation mode to obtain optimal control parameter is presented. First, The control input for the system in the HFC is a convex combination of the FLC's output in transient state and PID's output in steady state by a fuzzy variable, namely, membership function of weighting coefficient. Second, genetic algorithms is presented to automatically improve the performance of hybrid fuzzy controller utilizing the conventional methods for finding PID parameters and estimation mode of scaling factor. The algorithms estimates automatically the optimal values of scaling factors, PID parameters and membership function parameters of fuzzy control rules according to the rate of change and limitation condition of control input. Computer simulations are conducted to evaluate the performance of proposed hybrid fuzzy controller. ITAE, overshoot and rising time are used as a performance index of controller.

  • PDF

공간전압 벡터제어를 통한 유도전동기의 새로운 벡터제어성능연구 (A new vector control performance for induction motor with SVPWM)

  • 변윤섭;장동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2246-2248
    • /
    • 2001
  • This paper presents a new vector control scheme for induction motor. An exact knowledge of the rotor flux position is essential for a high-performance vector control. The position of the rotor flux is measured in the direct schemes and estimated in the indirect schemes. Since the estimation of the flux position requires a priori knowledge of the induction motor parameters, the indirect schemes are machine parameter dependent. The rotor and stator resistance among the parameters change with temperature. Variations in the parameters of induction machine cause deterioration of both the steady state and dynamic operation of the induction motor drive. Several methods have presented to minimize the consequences of parameter sensitivity in indirect scheme. In this paper, new estimation scheme of rotor flux position is presented to eliminate sensitivity due to variation in the resistance. The simulation is executed to verify the proposed vector control performance and to compare its performance with that of indirect and direct vector control.

  • PDF

예측 적응제어 기법을 이용한 전기 유압 모터의 제어에 관한 연구 (A Study on the Control of Electro-Hydraulic Motors Using Ahead Predictive Adaptive Control Method)

  • 김병우;허진
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1360-1365
    • /
    • 2011
  • Electro-hydraulic servo motor is used to a lot of in the field of industrial equipment which requires one of the control functions among pressure, flow, and power output. In this paper, linear discrete reference model of the electro-hydraulic servo motor system are made for 1-step ahead predictive control. The parameters of electro-hydraulic servo motor system are estimated using the recursive least square method. 1-step ahead predictive model output of electro-hydraulic servo motor system corresponded to reference model output in spite of estimated parameters are not meet real parameters. Control performance affections are studied due to the forgetting factors variation.

Optimal design of wind-induced vibration control of tall buildings and high-rise structures

  • Li, Qiusheng;Cao, Hong;Li, Guiqing;Li, Shujing;Liu, Dikai
    • Wind and Structures
    • /
    • 제2권1호
    • /
    • pp.69-83
    • /
    • 1999
  • The most common used control device on tall buildings and high-rise structures is active and passive tuned mass damper (ATMD and TMD). The major advantages of ATMD and TMD are discussed. The existing installations of various passive/active control devices on real structures are listed. A set of parameter optimization methods is proposed to determine optimal parameters of passive tuned mass dampers under wind excitation. Simplified formulas for determining the optimal parameters are proposed so that the design of a TMD can be carried out easily. Optimal design of wind-induced vibration control of frame structures is investigated. A thirty-story tall building is used as an example to demonstrate the procedure and to verify the efficiency of ATMD and TMD with the optimal parameters.

Dynamic response analysis of closed loop control system for intelligent truss structures based on probability

  • Gao, W.;Chen, J.J.;Ma, H.B.;Ma, X.S.;Cui, M.T.
    • Structural Engineering and Mechanics
    • /
    • 제15권2호
    • /
    • pp.239-248
    • /
    • 2003
  • The dynamic response analysis of closed loop control system based on probability for the intelligent truss structures with random parameters is presented. The expressions of numerical characteristics of structural dynamic response of closed loop control system are derived by means of the mode superposition method, in which the randomness of physical parameters of structural materials, geometric dimensions of active bars and passive bars, applied loads and control forces are considered simultaneously. The influences of the randomness of them on structural dynamic response are inspected by several engineering examples and some significant conclusions are obtained.

데드밴드 제어밸브를 가진 제어루프의 제어 개선 (Control Improvement of Control Loop with Deadband Control Valve)

  • 이광대;오응세;양승옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.318-320
    • /
    • 2006
  • A control valve with deadband characteristics influences on the control dynamics. A control loop with deadband component shows cyclic control results and causes the wears of mechanical parts. A valve on the important process that require nonstop operation cannot be improved during operation. In case of control loops with deadband dynamics, the optimal control parameters based on the performance only are not sure of the good operation in point of protecting the control component. To improve the control performance and control oscillation, the control parameters should be changed to meet both control qualify and protection of control components.

  • PDF