• 제목/요약/키워드: control loading system

검색결과 527건 처리시간 0.026초

6주간 야외용 운동기구를 사용한 저항운동이 노인 여성의 무릎신전근 기능 및 구조에 미치는 영향 (Effects of Six-week Resistance Exercise using an Outdoor Knee Extension Machine on Function and Structure of the Knee Extensor Muscles)

  • 최동성;김진선;김동일;전용관;원영신;이해동
    • 한국운동역학회지
    • /
    • 제22권2호
    • /
    • pp.201-208
    • /
    • 2012
  • The purpose of this study was to investigate the effect of leg extension exercises performed on outdoor resistance exercise machines on knee extension muscle strength and quadriceps muscle group cross sectional area (CSA) in elderly women. Two groups were recruited for this study, including an exercise group (EG: n=13, $71.38{\pm}2.79$ yrs) and a control group (CG: n=5, $73.4{\pm}5.94$), In all subjects, maximum isometric and isokinetic muscle strength of knee flexion and extension were measured using an isokinetic dynamometer (Cybex(R) Humac Norm Testing & Rehabilitation System, USA). Quadriceps muscle group CSA were measured using MRI (Philps, Intera 1.5 T, NE Netherlands). The results of this study showed that post-intervention isometric knee extension peak torque value were higher than pre-intervention measures in the EG. However, the EG did not show improvement in quadriceps muscle group CSA, Also, no differences in the shift of optimal knee joint angle were observed between pre and post-intervention exercise. Outdoor leg extension exercise showed small increases in muscle strength in comparison to other resistance training exercises. The results of this study suggest that because outdoor leg extension exercise machines lack a progressive loading mechanism, significant increases in muscle strength may not be obtained.

Effect of Cisplatin on $Na^+/H^+$ Antiport in the OK Renal Epithelial Cell Line

  • Kim, Jee-Yeun;Park, Yang-Saeng
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권1호
    • /
    • pp.69-76
    • /
    • 1998
  • Cis-diamminedichloroplatinum II (cisplatin), an effective antitumor agent, induces acute renal failure by unknown mechanisms. To investigate direct toxic effects of cisplatin in the renal proximal tubular transport system, OK cell line was selected as a cell model and $Na^+/H^+$ antiport activity was evaluated during a course of cisplatin treatment. The cells grown to confluence were treated with cisplatin for 1 hour, washed, and incubated for up to 48 hours. At appropriate intervals, cells were examined for $Na^+/H^+$ antiport activity by measuring the recovery of intracellular pH (pHi) after acid loading. Cisplatin of less than 50 ${\mu}M$ induced no significant changes in cell viability in 24 hours, but it decreased the viability markedly after 48 hours. In cells exposed to 50 ${\mu}M$ cisplatin for 24 hours, the $Na^+-dependent$ pHi recovery (i.e., $Na^+/H^+$ antiport) was drastically inhibited with no changes in the $Na^+-independent$ recovery. Kinetic analysis of the $Na^+-dependent$ pHi recovery indicated that the Vmax was reduced, but the apparent Km was not altered. The cellular $Na^+$ and $K^+$ contents determined immediately before the transport measurement appeared to be similar in the control and cisplatin group, thus, the driving force for $Na^+-coupled$ transport was not different. These results indicate that cisplatin exposure impairs the $Na^+/H^+$ antiport capacity in OK cells. It is, therefore, possible that in patients treated with a high dose of cisplatin, proximal tubular mechanism for proton secretion (hence $HCO_3^-$ reabsorption) could be attenuated, leading to a metabolic acidosis (proximal renal tubular acidosis).

  • PDF

기체발생기용 질산암모늄 산화제 기반 복합고체추진제의 조성 및 기계적 물성 (A Study on the Formulation and Mechanical Properties of AN-based Composite Solid Propellant for an Application to Gas Generators)

  • 박정;김정수
    • 한국추진공학회지
    • /
    • 제13권5호
    • /
    • pp.1-6
    • /
    • 2009
  • 로켓시스템의 에너지원으로 적용할 수 있는 기체발생기용 복합 고체추진제의 개발과정을 기술한다. 80%의 고체입자 부하율과 양호한 유동성, 그리고 $-50^{\circ}{\sim}70^{\circ}C$에서 경화에 적절한 추진제 물성을 갖는 HTPB를 바인더로 하여, 낮은 화염온도, 적은 고체입자 잔사, 무독성 생성물의 추진제 제조가 가능한 AN을 제1종 산화제로, 탄도특성 제어에 필요한 AP를 제2종 산화제로 추진제 주요 조성이 구성된다. 기본조성을 근거로 하여 일련의 물성개선 시험이 수행되었으며 최대응력 8 bar 및 최대응력점 변형율 30%, 그리고 탄성계수 1000 psi 수준의 물성을 갖는 추진제 조성을 얻을 수 있었다.

차세대 주력전차의 개념설계를 위한 동시공학의 적용 (Application of Concurrent Engineering for Conceptual design of a Future Main Battle Tank)

  • 김진우;소한균
    • 한국군사과학기술학회지
    • /
    • 제2권1호
    • /
    • pp.38-60
    • /
    • 1999
  • The main objective of this study is systemization of the technique of ROC quantification and optimization of baseline design by applying CE principle to the acquisition process of a weapon system. QFD and TOA techniques can be employed to a good working example of the conceptual design of a future main battle tank. In this paper, Product Planning Phase, the first phase of four QFD phases, is deployed in terms of eight steps including customer requirements and final product control characteristics. TOA is carried out considering only combat weight. In order to perform combat weight analysis and performance TOA, Preliminary Configuration Synthesis Methodology is used. Preliminary Configuration Synthesis Methodology employs the method of least squares and described linear equations of weight interrelation equation for each component of tank. As a result of QFD based upon the ROC, it was cleared that armor piercing power, main armament, type of ammunition, cruising range, combat weight, armor protection, power loading, threat detection and cost are primary factors influencing design and that combat weight is the most dominant one. The results of TOA based on the combat weight constraint show that 5100 lb reduction was required to satisfy the ROC. The baseline design of a future main battle tank is illustrated with assumption that all phases of QFD are employed to development and production process of subsystems, components, and parts of main battle tank. TOA is applied in iterative process between initial baseline design and ROC. The detailed design of each component is illustrated for a future main battle tank.

  • PDF

이음면 이격이 확장형 단부판 이음부 성능에 미치는 영향에 대한 실험적 연구 (Experimental Study of the End-plate Gap Effect on the Performance of Extended End-plate Type Splice)

  • 김철환;이명재;김희동;김사빈
    • 한국강구조학회 논문집
    • /
    • 제28권6호
    • /
    • pp.427-438
    • /
    • 2016
  • 두본 연구는 실험적인 방법을 통하여 단부판 이음부의 이음면에서 초기 오차로 발생하는 이격이 이음부의 내력 및 거동에 미치는 영향을 평가한 연구이다. 이를 위하여 총 5가지의 단순보형 실험체를 확장형 단부판 이음부를 이용 계획하였고 주요 변수로는 이음면 초기 이격(gap) 여부, 고력볼트 채결 전 끼움판(finger shim plate) 설치 유무, 고력볼트 체결 후 이음면 이격, 고력볼트 채결 후 끼움판 삽입 여부를 적용하였다. 정적가력실험 결과 이음판의 이격은 이음부의 최대휨강도에 미치는 영향은 제한적이나 수직변형과 초기 및 탄성강성에는 영향을 미치는 것으로 나타났으며, 이격을 제어하기 위해 고력볼트 장력을 이용할 경우 고력볼트의 취성파괴 우려도 있는 것으로 나타나서 이들에 대한 충분한 고려가 필요할 것으로 판단된다.

Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness

  • Nawafleh, Noor A;Hatamleh, Muhanad M;Ochsner, Andreas;Mack, Florian
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.416-422
    • /
    • 2017
  • PURPOSE. To investigate the effect of reducing tooth preparation and ceramic thickness on fracture resistance of lithium disilicate crowns. MATERIALS AND METHODS. Specimen preparation included a standard complete crown preparation of a typodont mandibular left first molar with an occlusal reduction of 2 mm, proximal/axial wall reduction of 1.5 mm, and 1.0 mm deep chamfer (Group A). Another typodont mandibular first molar was prepared with less tooth reduction: 1 mm occlusal and proximal/axial wall reduction and 0.8 mm chamfer (Group B). Twenty crowns were milled from each preparation corresponding to control group (n=5) and conditioned group of simultaneous thermal and mechanical loading in aqueous environment (n=15). All crowns were then loaded until fracture to determine the fracture load. RESULTS. The mean (SD) fracture load values (in Newton) for Group A were 2340 (83) and 2149 (649), and for Group B, 1752 (134) and 1054 (249) without and with fatigue, respectively. Reducing tooth preparation thickness significantly decreased fracture load of the crowns at baseline and after fatigue application. After fatigue, the mean fracture load statistically significantly decreased (P<.001) in Group B; however, it was not affected (P>.05) in Group A. CONCLUSION. Reducing the amount of tooth preparation by 0.5 mm on the occlusal and proximal/axial wall with a 0.8 mm chamfer significantly reduced fracture load of the restoration. Tooth reduction required for lithium disilicate crowns is a crucial factor for a long-term successful application of this all-ceramic system.

SiOC 매트(Mat)를 이용한 열전지용 전해질 격리판 제조 및 특성 (Properties of the Electrolyte Separators for Thermal Batteries Using SiOC Mat)

  • 임경훈;조광연;류도형;신동근;진은주;김현이;정해원;이홍림
    • 한국세라믹학회지
    • /
    • 제46권6호
    • /
    • pp.648-652
    • /
    • 2009
  • Ceramic fiber separator is the promising material for thermal battery system because it reduces the production cost and offers the potential to a new application compared to a pellet type electrolyte. The electrolyte separator for thermal battery should be easily handled and loaded a large amount of the molten lithium salt. Ceramic fibers were used as an electrolyte separator and the lithium based molten salts were infiltrated into the ceramic filters. Leakage of molten salt (several lithium salts) leads to short-circuit during the thermal battery operation. In this study, a uniform and fine SiOC mat with fibers ranging from 1 to 3 ${\mu}m$ was obtained by electrospinning of polycarbosilane and pyrolysis. The optimum spinning conditions for obtaining fine diameters of SiOC fiber were controlled by the solution composition and concentration, applied voltage and spinning rate, release rate by porosity. The pore structures of the ceramic filter and the melting properties of the lithium salts affected to the electrolyte loading and leakage. The importance of the fiber size and porosity and their control was discussed and the mechanical properties were also discussed.

에어로솔의 대륙 층운형 구름 연직발달(Invigoration)에 미치는 영향 분석 (An Analysis of Aerosols Impacts on the Vertical Invigoration of Continental Stratiform Clouds)

  • 김유준;한상옥;이철규;이승수;김병곤
    • 대기
    • /
    • 제23권3호
    • /
    • pp.321-329
    • /
    • 2013
  • This study examines the effect of aerosols on the vertical invigoration of continental stratiform clouds, using a dataset of Atmospheric Radiation Measurement (ARM) Intensive Operational Period (IOP, March 2000) at the Southern Great Plains (SGP) site. To provide further support to our observation-based findings, the weather research and forecasting (WRF) sensitivity simulations with changing cloud condensation nuclei (CCN) concentrations have been carried out for the golden episode over SGP. First, cross correlation between observed aerosol scattering coefficient and cloud liquid water path (LWP) with a 160-minutes lag is the highest of r = 0.83 for the selected episode, which may be attributable to cloud vertical invigoration induced by an increase in aerosol loading. Modeled cloud fractions in a control run are well matched with the observation in the perspective of cloud morphology and lasting period. It is also found through a simple sensitivity with a change in CCN that aerosol invigoration (AIV) effect on stratiform cloud organization is attributable to a change in the cloud microphysics as well as dynamics such as the corresponding modification of cloud number concentrations, drop size, and latent heating rate, etc. This study suggests a possible cloud vertical invigoration even in the continental stratiform clouds due to aerosol enhancement in spite of a limited analysis based on a few observed continental cloud cases.

합성가스(Reforming gas)를 이용한 멀티채널 CDPF의 재생 특성 연구 (Studies on Reforming Gas Assisted Regeneration of Multi-channel Catalyzed DPF)

  • 최광춘;정진화;송순호;전광민
    • 한국자동차공학회논문집
    • /
    • 제19권3호
    • /
    • pp.138-145
    • /
    • 2011
  • Diesel particulate filter (DPF) systems are being used to reduce the particulate matter emission of diesel vehicles. The DPF should be regenerated after certain driving hours or distance to eliminate soot in the filter. The most widely used method is active regeneration with oxygen at $550{\sim}650^{\circ}C$. Syngas (synthetic gas) can be used to lower the regeneration temperature of Catalyzed DPF (CDPF). The syngas is formed by fuel reforming process of CPOx (Catalytic Partial Oxidation) at specific engine condition (1500rpm, 2bar) using 1wt.% $Rh/CeO_2-ZrO_2$ catalyst. The oxidation characteristics of PM with syngas supplied to filter were studied using partial flow system that can control temperature and flow rate independently. The filter is coated with washcoat loading of $25g/ft^3$ $Pt/Al_2O_3-CeO_2$, and multi-channel CDPF (MC-CDPF) was used. The filter regeneration experiments were performed to investigate the effect of syngas exothermic reaction on soot oxidation in the filter. For this purpose, before oxidation experiment, PM was collected about 8g/L to the filter at engine condition of 1500rpm, bmep 8bar and flow temperature of $200^{\circ}C$ Various conditions of temperature and concentration of syngas were used for the tests. Regeneration of filter started at 2% $H_2$ and CO concentration respectively and inlet temperature of $260^{\circ}C$. Filter Regeneration occurs more actively as the syngas concentration becomes higher.

흡연자와 비흡연자의 행동양상 연구 (A Study on Behavior Patterns Between Smokes and Non-Smokers)

  • 김화신
    • 대한간호학회지
    • /
    • 제20권1호
    • /
    • pp.79-87
    • /
    • 1990
  • Clinical and epedemiologic studies of coronary heart disease(CHD)have from time to time over the last three decades found associations between prevalence of CHD and behavioral attributes and cigarette smoking. The main purpose of this study is reduced to major risk factor of coronary heart disease through prohibition of smoking and control of behavior pattern. The subjects consisted of 120 smokers and 90 non-smokers who were married men older than 30 years working in officers. The officers were surveyed by means of questionnaire September 26 through October 6, 1989. The Instruments used for this study was a self-administered measurement tool composed of 59 items was made through modifications of Jenkuns Activity Survery(JAS). The Data were analysed by SAS(Statistical Analsis System) program personal computer. The statistical technique used for this study were Frequency, x$^2$-test, t-test, ANOVA, Pearson Correlation Coefficient. The 15 items were chosen with items above 0.3 of the factor loading in the factor analysis. In the first factor analysis 19 factors were extracted and accounted for 86% of the total variance. However when the number of factors were limited to 3 in order to derive Jenkins classification, three factors were derived. There names are Job-Involvement, Speed & Impatience, Hard-Driving. Each of them includes 21 items, 21 and 9, respectively. The results of this study were as follow : 1. The score of the smoker group and non-smoker group in Job-Involvement(t=5.7147, p<0.0001), Speed & Impatience(t=4.6756, p<.0001), Hard-Driving(t=8.0822, p<.0001) and total type A behavior pattern showed statistically significant differences(t=8.1224, p<.0001). 2. The score of type A behavior pattern by number of cigarettes smoked daily were not statistically significant differences. 3. The score of type A behavior pattern by duration of smoking were not significant differences. It was concluded that the relationship between smokers and non - smokers of type A behavior pattern was statistically significant difference but number of cigarettes smoked daily and duration of smoking were not significant differences. Therefore this study is needed to adequate nursing intervention of type A behavior pattern in order to elevated to educational effect for prohibition of cigarette smoking.

  • PDF