• 제목/요약/키워드: contrast value

검색결과 1,406건 처리시간 0.028초

Super High Contrast Ratio of TN mode TFT- LCD by Taguchi Design

  • Huang, Y.J.;Chao, Andy;Huang, K.T.;Hung, Y.W.;Yu, C.H.;Wu, H.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1652-1655
    • /
    • 2008
  • A new high contrast LCD structure for TN mode TFT-LCD, of which the contrast ratio is 1.2 times hi gher than that of the conventional one, has been developed. The contrast ratio of TFT-LCD display can be improved by some modified materials, which like as polarizer, liquid crystal, color filter and light enhancement film. In order to know which condition can get the major contribution for the upgrade of the contrast ratio, we used Taguchi method and analyzed the contribution ratio for each composition and succeed to build up the formula of contrast ratio. From this study, we could achieve the highest CR value as 1200:1 of TN mod e TFT-LCD nowadays.

  • PDF

비주얼 센서 영상에 대한 대비 개선 방법 (Contrast Enhancement Method for Images from Visual Sensors)

  • 박상현
    • 한국전자통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.525-532
    • /
    • 2018
  • 최근 센서 네트워크 기술의 발달과 카메라 기술의 발달로 이 두 기술을 접목한 비주얼 센서 기술을 이용하여 사람이 접근하기 어려운 지역의 환경을 효과적으로 모니터링하고자 하는 수요가 증가하고 있다. 비주얼 센서에서 획득된 영상은 자연 현상을 그대로 반영하기 때문에 날씨나 시간에 따라 영상의 품질이 나빠질 수 있다. 이 논문에서는 비주얼 센서에서 획득되는 영상의 특성을 이용하여 영상의 대비를 개선하는 알고리즘을 제안한다. 제안하는 방법에서는 먼저 비주얼 센서가 촬영하는 대상에 대해서 관심 영역을 설정하고 관심 영역의 컬러 값의 변화를 영상의 밝기 값에 따라 분석한다. 그리고 분석한 결과와 동일한 대상의 고대비 영상을 이용하여 저대비 영상의 대비를 개선한다. 실험 결과는 제안하는 방법이 간단하면서도 정확하게 저대비 영상의 컬러 성분들을 복원하여 영상의 대비를 개선하는 것을 보여준다.

A Versatile Medical Image Enhancement Algorithm Based on Wavelet Transform

  • Sharma, Renu;Jain, Madhu
    • Journal of Information Processing Systems
    • /
    • 제17권6호
    • /
    • pp.1170-1178
    • /
    • 2021
  • This paper proposed a versatile algorithm based on a dual-tree complex wavelet transform for intensifying the visual aspect of medical images. First, the decomposition of the input image into a high sub-band and low-sub-band image is done. Further, to improve the resolution of the resulting image, the high sub-band image is interpolated using Lanczos interpolation. Also, contrast enhancement is performed by singular value decomposition (SVD). Finally, the image reconstruction is achieved by using an inverse wavelet transform. Then, the Gaussian filter will improve the visual quality of the image. We have collected images from the hospital and the internet for quantitative and qualitative analysis. These images act as a reference image for comparing the effectiveness of the proposed algorithm with the existing state-of-the-art. We have divided the proposed algorithm into several stages: preprocessing, contrast enhancement, resolution enhancement, and visual quality enhancement. Both analyses show the proposed algorithm's effectiveness compared to existing methods.

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.

Shape Preserving Contrast Enhancement

  • Hwang Jae Ho
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.867-871
    • /
    • 2004
  • In this paper, a new analytic approach for shape preserving contrast enhancement is presented. Contrast enhancement is achieved by means of segmental histogram stretching modification which preserves the given image shape, not distorting the original shape. After global stretching, the image is partitioned into several level-sets according to threshold condition. The image information of each level-set is represented as typical value based on grouped differential values. The basic property is modified into common local schemes, thereby introducing the enhanced effect through extreme discrimination between subsets. The scheme is based on stretching the histogram of subsets in which the intensity gray levels between connected pixels are approximately same In spite of histogram widening, stretched by local image information, it neither creates nor destroys the original image, thereby preserving image shape and enhancing the contrast. By designing local histogram stretching operations, we can preserve the original shape of level-sets of the image, and also enhance the global intensity. Thus it can hold the main properties of both global and local image schemes, which leads to versatile applications in the field of digital epigraphy.

  • PDF

X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구 (A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter)

  • 김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

간 섬유화 평가를 위한 MR elastography의 경직도에 대한 Gd-EOB-DTPA의 영향 (The Effect of Gd-EOB-DPTA on the Stiffness Value of Magnetic Resonance Elastography in Evaluating Hepatic Fibrosis)

  • 이정은;이정민;이예지;윤정희;이경분;한준구;최병인
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권3호
    • /
    • pp.215-223
    • /
    • 2013
  • 목적: 간 섬유화를 평가하기 위한 MR elastography (MRE)의 경직도 (stiffness value)에 미치는 gadoxetic acid의 영향을 평가하고자 하였다. 대상과 방법: 임상적으로 만성 간 질환이 의심되어 자기공명영상을 촬영한 환자 중 조영제 (gadoxetic acid) 주입전과 후에 MRE를 촬영한 32명의 환자를 대상으로 하였다. 두 명의 영상의학과 의사가 간 실질의 경직도를 개별적으로 측정 하였다. 조영 전과 후의 평균 간경직도를 paired t-test를 사용하여 비교하였으며, 평가자내 및 평가자간 상관 관계는 intraclass correlation coefficient (ICC)를 사용하여 분석 하였다. MRE의 F2 이상의 간섬유화 진단의 판별수치로 3.1 kPa을 이용하여 진단의 정확도, 민감도, 특이도를 구하였다. 결과: 조영 전과 후에 측정된 간 경직도의 평균값은 유의한 차이가 없었으며 (p > 0.05), 조영 전 후 모두에서 평가자 내 및 평가자간 우수한 상관 관계가 관찰되었다 (ICC = 0.988 for pre-contrast and ICC = 0.993 for post-contrast, ICC = 0.998 for rater 1 and ICC = 0.996 for rater 2). 간섬유화정도 F2 이상을 진단하는 MRE 의 정확도, 민감도, 특이도는 조영 전후 모두에서 각각 71%, 60%, 그리고 100%로 같은 값을 보였다. 결론: MRE를 이용한 gadoxetic acid 조영 전과 후에 측정된 간경직도는 유의한 차이를 보이지 않았기에 조영 후 MRE 영상도 간 섬유화 평가에 이용될 수 있다.

A Study on the Evaluation Method of Perceptual Contrast with CIECAM02

  • Chong, Jong-Ho;Lee, Seung-Bae;Lee, Sang-Myung;Choi, Young-Chul;Bae, Jae-Woo;Kim, Hun-Soo;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1661-1663
    • /
    • 2007
  • The contrast of display is one of the important specifications. Even if the contrast indicates luminance range which is a capability of the display and is greater in lower luminance or higher luminance, we consider that the greater contrast gets not the better performance. It is not the same value in human visual system. In practice, it is difficult to achieve the full dynamic range seen by human beings using electronic equipment. Therefore, we consider ambient condition and human perception to calculate perceptual contrast using the CIECAM02. In this paper, we propose perceptual contrast that is calculated using the brightness of CIECAM02.

  • PDF