• 제목/요약/키워드: contrast flow

검색결과 496건 처리시간 0.023초

고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구 (A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans)

  • 조진수;한철희;조이상
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

유로단면이 변하는 수평관 내 기포류에서의 기포 및 액체 속도 (Bubble and Liquid Velocities for a Bubbly Flow in an Area-Varying Horizontal Channel)

  • 찬탄짬;김병재;박현식
    • 한국가시화정보학회지
    • /
    • 제15권3호
    • /
    • pp.20-26
    • /
    • 2017
  • The two-fluid equations are widely used to simulate two-phase flows in a nuclear reactor. For the two-fluid momentum equation, the wall and interfacial drag terms play an important role in predicting a two-phase flow behavior. Since the bubble density is much smaller than the water density, the bubble accelerates faster than the liquid in a nozzle. As a result, the bubble phase becomes faster than the liquid phase in the nozzle. In contrast, the opposite phenomena occur in the diffuser. The purpose of our study is to experimentally show these behaviors in an area-varying channel such as nozzle and diffuser. Experiments were made of turbulent bubbly flows in an area-varying horizontal channel. The velocities of the bubble and liquid phases were measured by the PIV technique. It was shown that the two-phase velocities were no longer close to each other in the area-varying regions. The bubble was faster than the liquid in the nozzle; in contrast, the bubble was slower than the liquid in the diffuser. Code simulations were also performed using the MARS code. By replacing the original wall drag model in the MARS code with Kim (1)'s wall drag partition model, we obtained the simulation results being consistent with experimental observations.

우천 상황에 강인한 CLAHE를 적용한 Adaboost 기반 차량 검출 방법 (Robust vehicle Detection in Rainy Situation with Adaboost Using CLAHE)

  • 강석준;한동석
    • 한국통신학회논문지
    • /
    • 제41권12호
    • /
    • pp.1978-1984
    • /
    • 2016
  • 본 논문에서는 영상의 대비효과를 부각시키는 CLAHE(Contrast-Limit Adaptive Histogram Equalization)를 적용한 Adaboost 기반 방법을 통해 우천 상황에서 강인한 차량 검출 방법을 제안한다. 본 논문에서는 차량 검출의 효과적인 실시간 동작을 위해 2가지를 제안하였다. 먼저 영상의 RGB값을 통해 우천 상황 여부를 판단하여 검출 방법을 선택할 수 있도록 하여 연산량을 줄이는 것과 CLAHE를 이용한 영상 처리를 통해 영상 내에 차량의 후미등을 검출하여 관심영역을 지정해주는 방법을 제안했다. 또한 본 논문에서는 기존에 차량 검출 방법으로 제시되었던 가우시안 혼합 모델(Gaussian Mixture Model), 옵티컬 플로우(Optical Flow)와 Adaboost(Adaptive boosting)의 우천 상황에서의 차량 검출율을 비교하여 최종적으로 Adaboost를 선택한 이유를 설명했다. 본 논문 실험 결과는 CLAHE 미적용 시 정확율과 재현율은 각각 0.83, 0.77 이었고, CLAHE 적용 시 0.85, 0.87로 적용했을 때 정확율과 재현율에서 약 2%, 13% 향상되었다.

Assessment of Pollution Levels in the Jangsungcheon Watershed Using Load Duration Curves and Analysis of the Causes

  • Cho, Sohyun;Bak, Jonghun;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang Young
    • 한국환경과학회지
    • /
    • 제28권10호
    • /
    • pp.873-885
    • /
    • 2019
  • In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were $0.25m^3/s$ and $1.08m^3/s$, respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.

좁은 채널 내의 대향분류 메탄-공기 비예혼합 화염의 거동 특성 (Behavioral Characteristics of the Non-Premixed Methane-Air Flame Oppositely Injected in a Narrow Channel)

  • 윤영민;이민정;조상문;김남일
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.264-271
    • /
    • 2009
  • Characteristics of a counter flowing diffusion flame, which is formulated by an oppositely-injected methane-jet flow in a narrow channel of a uniform air flow. The location of the flame fronts and the flame lengths were compared by changing the flow rates of fuel. To distinguish the effects of the narrow channel on the diffusion flame, a numerical simulation for an ideal two-dimensional flame was conducted. Overall trends of the flame behavior were similar in both numerical and experimental results. With the increase of the ratio of jet velocity to air velocity flame front moved farther upstream. It is thought that the flow re-direction in the channel suppresses fuel momentum more significantly due to the higher temperature and increased viscosity of burned gas. Actual flames in a narrow channel suffer heat loss to the ambient and it has finite length of diffusion flame in contrast to the numerical results of infinite flame length. Thus a convective heat loss was additionally employed in numerical simulation and closer results were obtained. These results can be used as basic data in development of a small combustor of a nonpremixed flame.

Synchrotron X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측 (In Vivo Visualization of Flow in Xylem Vessels of a Bamboo Leaf Using Synchrotron X-ray Micro Imaging Technique)

  • 김양민;이상준
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1612-1617
    • /
    • 2003
  • Synchrotron X-ray micro imaging technique was employed to non-invasively monitor the water flow inside xylem vessels in a bamboo leaf. The phase contrast X-ray images clearly visualized plant anatomy and the rise of a water front inside the vessels. Consecutive X-ray images taken for 60 seconds revealed water rise kinetics against gravity in the xylem of a cut dry leaf taken from a bamboo tree. For the first time, traces of water rise, variation of contact angle between water and xylem wall as well as the internal structure of xylem were obtained. In xylem vessels, a repeating flow pattern has a typical flow velocity of 30.7$\mu\textrm{m}$/s and faster flow is established intermittently. It is concluded that the transmission type of X-ray micro imaging can be used as a powerful tool to investigate the ascent of sap in the xylem vessels at a resolution higher than that of MRI.

정상유동에서 유동형 단엽폴리머 인공판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Valve under Steady Flow Condition)

  • 김준우;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.49-60
    • /
    • 1996
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) withdifferent leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison test. Pressure drops of MLPVS are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of the polymer valve, the larger are the corresponding pressure drop. The velocity profiles for MLPs reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVS at a flow rate of $30{\ell}$/min are in the range 50-130 dyn/$cm^2$, and the corresponding maximum Reynolds shear stresses are in the range of 100-500 dyn/$cm^2$, respectively, which are beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it may be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the Important parameters.

  • PDF

정상유동에서 유동형 단엽폴리머 인공심장판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Heart Valve under Steady Flow Condition)

  • 박복춘;김준우;백병준;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.241-246
    • /
    • 1995
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) with different leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison tests. Pressure drops of MLPVs are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of a polymer valve, the larger arc the corresponding press drop. The velocity profiles for MLPV reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVs at a flow rate of 30 l/min are in the range $54-130\;dyn/cm^2$, and the corresponding maximum. Reynolds shear stresses are in the range of $100-500\;dyn/cm^2$, respectively. Both arc beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it can be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the important parameters.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정 (Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF