• Title/Summary/Keyword: contrast difference

Search Result 1,500, Processing Time 0.024 seconds

Usefulness of ultrasound contrast media for cardiac output measurement with echocardiography

  • Yun, Je Woong;Yeon, Seong Chan;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.1
    • /
    • pp.47-52
    • /
    • 2015
  • The purpose of this study was to determine if contrast media would enhance visualization of the endocardium for assessment of left ventricle (LV) function. In addition, differences between pre- and post-contrast evaluation for the cardiac output measurements including the modified Simpson's method and automated contour tracking (ACT) method were examined. Ten clinically healthy adult beagle dogs (three males and seven females) between 2~3 years old and weighing 6.6~10.8 kg were used. Echocardiographic examinations were performed to compare pre- and post-contrast LV endocardium visualization using a segmental scoring method. Two different methods for measuring cardiac output were also compared. LV visualization was significantly enhanced in post-contrast echocardiography (p < 0.01). Significant differences between pre- and post-contrast measurements for the modified Simpson's method (p < 0.05) were also observed. No significant difference was found for the ACT method. Contrast echocardiography provides better LV chamber opacification and significantly improves wall segment visualization. Furthermore, contrast echocardiography for measuring cardiac output is helpful for the modified Simpson's method.

Safety of Administering Intravenous CT Contrast Agents Repeatedly or Using Both CT and MRI Contrast Agents on the Same Day: An Animal Study

  • Heejin Bae;Hyewon Oh;Ga Bin Park;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.25 no.3
    • /
    • pp.257-266
    • /
    • 2024
  • Objective: To investigate molecular and functional consequences of additional exposures to iodine- or gadolinium-based contrast agents within 24 hours from the initial intravenous administration of iodine-based contrast agents through an animal study. Materials and Methods: Fifty-six Sprague-Dawley male rats were equally divided into eight groups: negative control, positive control (PC) with single-dose administration of CT contrast agent, and additional administration of either CT or MR contrast agents 2, 4, or 24 hours from initial CT contrast agent injection. A 12 µL/g of iodinated contrast agent or a 0.47 µL/g of gadolinium-based contrast agent were injected into the tail vein. Serum levels of blood urea nitrogen, creatinine, cystatin C (Cys C), and malondialdehyde (MDA) were measured. mRNA and protein levels of kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL) were evaluated. Results: Levels of serum creatinine (SCr) were significantly higher in repeated CT contrast agent injection groups than in PC (0.21 ± 0.02 mg/dL for PC; 0.40 ± 0.02, 0.34 ± 0.03, and 0.41 ± 0.10 mg/dL for 2-, 4-, and 24-hour interval groups, respectively; P < 0.001). There was no significant difference in the average Cys C and MDA levels between PC and repeated CT contrast agent injection groups (Cys C, P = 0.256-0.362; MDA, P > 0.99). Additional doses of MR contrast agent did not make significant changes compared to PC in SCr (P > 0.99), Cys C (P = 0.262), and MDA (P = 0.139-0.771) levels. mRNA and protein levels of KIM-1 and NGAL were not significantly different among additional CT or MR contrast agent groups (P > 0.05). Conclusion: A sufficient time interval, probably more than 24 hours, between repeated contrast-enhanced CT examinations may be necessary to avoid deterioration in renal function. However, conducting contrast-enhanced MRI on the same day as contrast-enhanced CT may not induce clinically significant kidney injury.

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Harmony Perception according to Contrast Coloration of Shirt and Necktie by Male and Female (셔츠와 넥타이의 컨트라스트 배색에 대한 남녀의 조화감 지각)

  • Lim, Ji-Young;Kang, Kyung-Ja
    • The Research Journal of the Costume Culture
    • /
    • v.15 no.5
    • /
    • pp.838-851
    • /
    • 2007
  • The purpose of this research was to investigate the harmony evaluation and the effects used clues on harmony perception in terms of 128 contrast coloration of male shirt and necktie by male and female students. The results are as follows. Among 128 contrast coloration stimuli, female students evaluated 42 set, male students 50 set, so proved that male's range of harmony more extensive than that of female. It is significant difference between female and male on shirt-necktie coloration; vivid red shirt-vivid green tie, dull red shirt-dark blue tie, light red shirt-dull blue tie, dark red shirt-light blue tie, light green shirt-vivid violet tie, light green shirt-light red tie, light green shirt-dull red tie. Especially, in contrast coloration, it was evaluated as harmonized coloration by both male and female as tie was dark tone on the whole.

  • PDF

Color Saturation Improvement using the Maximum Color Difference Table (최대색차신호 표를 이용한 컬러 채도 향상)

  • Kim, Sun-Jung;Hong, Sung-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.119-130
    • /
    • 2013
  • In this paper, we propose a new color image enhancement method to improve the color saturation as well as luminance contrast in the YCbCr color space. The proposed method uses the maximum color difference table to compensate the perceived saturation changes due to luminance contrast changes. To improve the color saturation, the method first calculates the weighting factor by using the maximum color difference table and then multiplies the weighting factor to the input color difference signals. In this step, it maps color difference signals to proper color region to prevent the color distortion by considering the correlation of color saturations depending on the luminance and hue. The experimental results show that our method effectively improves color saturation compared to the conventional methods.

Perceptual Quality-based Video Coding with Foveated Contrast Sensitivity (Foveated Contrast Sensitivity를 이용한 인지품질 기반 비디오 코딩)

  • Ryu, Jiwoo;Sim, Donggyu
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.468-477
    • /
    • 2014
  • This paper proposes a novel perceptual quality-based (PQ-based) video coding method with foveated contrast sensitivity (FCS). Conventional methods on PQ-based video coding with FCS achieve minimum loss on perceptual quality of compressed video by exploiting the property of human visual system (HVS), that is, its sensitivity differs by the spatial frequency of visual stimuli. On the other hand, PQ-based video coding with foveated masking (FM) exploits the difference of the sensitivity of the HVS between the central vision and the peripheral vision. In this study, a novel FCS model is proposed which considers both the conventional DCT-based JND model and the FM model. Psychological study is conducted to construct the proposed FCS model, and the proposed model is applied to PQ-based video coding algorithm implemented on HM10.0 reference software. Experimental results show that the proposed method decreases bitrate by the average of 10% without loss on the perceptual quality.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT 에서의 간암-간 대조 곡선의 Simulation)

  • Kim, S.J.;Lee, K.H.;Kim, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.271-272
    • /
    • 1998
  • Contrast-enhanced CT has an important role in the assessment of liver lesions. However, the optimal protocol to get most effective result is not clear. The main principle for deciding injection protocol is to optimize lesion detectability by rapid scanning when lesion-to-liver contrast is maximum. For this purpose, we developed a physiological model of contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver was modeled in two paths. This dual supply character distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and the second is by portal vein. It is assumed that only hepatic artery can supply blood to hepatocellular carcinoma (HCC) compartment. It is known that this causes the difference of contrast enhancement between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using computer program Matlab, CT contrast-enhancement curves were simulated. Simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with mean enhancement curves from 24 patients exposed to the same protocols as simulation. These enhancement curves were in a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and analyzed the effects. These may help to optimize the scanning protocols for good diagnosis.

  • PDF

Blind Quality Metric via Measurement of Contrast, Texture, and Colour in Night-Time Scenario

  • Xiao, Shuyan;Tao, Weige;Wang, Yu;Jiang, Ye;Qian, Minqian.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.4043-4064
    • /
    • 2021
  • Night-time image quality evaluation is an urgent requirement in visual inspection. The lighting environment of night-time results in low brightness, low contrast, loss of detailed information, and colour dissonance of image, which remains a daunting task of delicately evaluating the image quality at night. A new blind quality assessment metric is presented for realistic night-time scenario through a comprehensive consideration of contrast, texture, and colour in this article. To be specific, image blocks' color-gray-difference (CGD) histogram that represents contrast features is computed at first. Next, texture features that are measured by the mean subtracted contrast normalized (MSCN)-weighted local binary pattern (LBP) histogram are calculated. Then statistical features in Lαβ colour space are detected. Finally, the quality prediction model is conducted by the support vector regression (SVR) based on extracted contrast, texture, and colour features. Experiments conducted on NNID, CCRIQ, LIVE-CH, and CID2013 databases indicate that the proposed metric is superior to the compared BIQA metrics.

Quality Assessment of Film Processing Chemicals in Dentistry (치과에서 사용되는 필름 현상액에 대한 품질 평가 연구)

  • Han Mi-Ra;Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.299-308
    • /
    • 1999
  • Purpose: The purpose of this study was to compare the qualities of the four different processing chemicals (solutions). Materials and Methods: With EP 21 films(Ektaspeed plus film, Kodak Co., USA), nine unexposed and nine exposed films of a step wedge were processed utilizing automatic film processor(XR 24, Durr Co., Germany) for 5 days. During 5 days, the total number of processed films including out-patient' s intraoral films were about 400-500 for each brand. Base plus fog density, film density, contrast of processed films were measured with densitometer(model 07-443 digital densitometer, Victoreen Co., USA). These measurements were analyzed for comparison. Results: The results were as follows, 1. For the base plus fog density. there was significant difference among the four chemicals (p<0.05). The sequence of the base plus fog densities was in ascending order by Kodak, X-dol 90. Agfa and Konica. 2. For the film density. all chemicals showed useful range of photographic densities(0.25-2.5). The sequence of the film densities was in ascending order by Kodak, X-dol 90, Konica and Agfa. But there was no statistically significant difference of film density between X-dol and Kodak (p<0.05). 3. The sequence of the contrasts was in ascending order by Konica, X-dol 90, Kodak and Agfa. But there was no statistically significant difference of contrast between X-dol and Konica (p<0.05). Conclusion: These results indicated that the four processing chemicals had clinically useful film density and contrast. but only Kodak processing chemical had useful base plus fog density.

  • PDF

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.