• Title/Summary/Keyword: contouring method

검색결과 77건 처리시간 0.026초

GIS 기법을 활용한 서울시 VOCs 오염도평가에 관한 연구 (Assessment of the VOCs Concentration Using GIS Method of Seoul)

  • 박기학;정용;조성준
    • 환경영향평가
    • /
    • 제10권2호
    • /
    • pp.135-145
    • /
    • 2001
  • This study was conducted to investigate the practical using of Geographic Information System(GIS) technology which are computer-based systems that are used to store and manipulate geographic information on the air pollution control and management in the macro city. For this study 130 samples were corrected by passive sampler in Seoul (25 distincts) distributed by TM-coordinate during November in 1997 to January 1998, and analysed by GC/MSD for 16 VOCs e.g., toluene, benzene and display using Arc/view GIS(version 3.2, ESRI Inc, U.S.A) for windows. The most VOCs concentration distribution in November, 1997 was higher than that of January, 1998 except benzene and 1,1,2-trichroloethan, bromobenzene. And products of the distribution of VOCs concentration display using GIS technology was effective as well as other display methods(e.g., contouring method, pie or column chart, graduated symbols), especially in mapping and symbolization capabilities for spatial pollutant status evaluation were very effective than other display methods.

  • PDF

GIS 기법을 활용한 대기오염관리에 관한 연구(I)-서울시 VOCs 오염도를 중심으로- (A Study on the Air Pollution Management Using GIS Method(I)-Focus on VOCs concentration of Seoul-)

  • 박기학;조성준;유영대
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.100-107
    • /
    • 2001
  • On the planning for the systematic management and control of the air pollution display methods were used to evaluate the spatial pollutant concentration status. This study were conducted to investigate the practical using of Geographic Information System(GIS) technology on the air pollution control and management which were computer-based systems that were used to store and manipulate geographic information in the macro city. In this study 137 samples were corrected by passive samplers and analysed by GC/MSD for 16 VOCs in Seoul (25 distincts) distributed by TM-coordinate(2 km$\times$2km), and finally displayed by Arciew program(version 3.2, ESRI Inc, USA) for windows. The concentration of benzene and toluene showed high level in whole area of seoul area of Seoul and distribution of butylbenzen, trothroloetylene, stylen showed high level in whole area of Seoul except a few distincts and the distribution of isopropylbenzene, 1,2-dichroloethane showed higher level in core area than that of Kangnam and Kangbuk area. In conclusion, products of this study of using GIS technology apply on the spatial distribution of VOCs concentration was very effective than that of other methods(e.g., contouring concentration method, pie or column chart, graduated symbols), especially in mapping and symbolization of pollution status evaluation.

  • PDF

유한차분모형을 위한 직사각형 격자정보 생성기법 (Generation Method of the Rectangular Grid Information for Finite Difference Model)

  • 정신택;조범준;김정대
    • 한국해안해양공학회지
    • /
    • 제15권3호
    • /
    • pp.190-195
    • /
    • 2003
  • 연안 및 해안에서 발생하는 파랑변형, 조석 전파, 부유사 이동 및 확산 현상 등을 예측하기 위해서는 수치모형이 주로 사용된다 대표적인 수치모형 기법으로는 유한차분법 및 유한요소법이 있다. 유한차분법을 사용하는 경우에는 관심영역의 각 격자점에서 유한차분 방정식을 풀어야하므로, 격자망 및 경계조건 등이 설정되어야 한다. 유한차분용 격자망은 유한요소법과는 달리 격자망이 간단하지만, 지형이 복잡한 경우에 편리하게 사용 할 수 있는 격자정보 생성기법이 별로 개발되어 있지 않다. 또한, 상업용으로 많이 개발되어 있는 프로그램도 대부분 유한요소법에 근거한 수치모형에서 사용하는 격자생성을 목적으로 하고 있다. 본 연구에서는 디지타이저(Summagrid IV 기종)를 사용하여 유한차분모형을 위한 동일한 간격의 직사각형 격자 수심자료를 만드는 세부과정을 자료로 소개하고자 한다. 필요한 프로그램은 Golden Software사의 Didger(dititiger 지원 S/W)와 Surfer(gridding & contouring S/W)로서, 비교적 간단하게 정확한 수심 자료를 얻을 수 있으며, 임의의 지점 떠는 영역에 제시된 정보로부터 필요한 직사각형 격자정보를 추출하는 방법에 적용이 가능하다.

The path of placement of a removable partial denture: a microscope based approach to survey and design

  • Mamoun, John Sami
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.76-84
    • /
    • 2015
  • This article reviews the topic of how to identify and develop a removable partial denture (RPD) path of placement, and provides a literature review of the concept of the RPD path of placement, also known as the path of insertion. An optimal RPD path of placement, guided by mutually parallel guide planes, ensures that the RPD flanges fit intimately over edentulous ridge structures and that the framework fits intimately with guide plane surfaces, which prevents food collecting empty spaces between the intaglio surface of the framework and intraoral surfaces, and ensures that RPD clasps engage adequate numbers of tooth undercuts to ensure RPD retention. The article covers topics such as the causes of obstructions to RPD intra-oral seating, the causes of food collecting empty spaces that may exist around an RPD, and how to identify if a guide plane is parallel with the projected RPD path of placement. The article presents a method of using a surgical operating microscope, or high magnification (6-8x or greater) binocular surgical loupes telescopes, combined with co-axial illumination, to identify a preliminary path of placement for an arch. This preliminary path of placement concept may help to guide a dentist or a dental laboratory technician when surveying a master cast of the arch to develop an RPD path of placement, or in verifying that intra-oral contouring has aligned teeth surfaces optimally with the RPD path of placement. In dentistry, a well-fitting RPD reduces long-term periodontal or structural damage to abutment teeth.

외란관측기를 이용한 볼스크류 구동 2축 서보계의 최적튜닝 (Optimal Tuning of a Ballscrew Driven Biaxial Servo System)

  • 신동수;정성종
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.589-597
    • /
    • 2011
  • In this paper, optimal tuning of a cross-coupled controller linked with the feedforward controller and the disturbance observer is studied to improve contouring and tracking accuracy as well as robustness against disturbance. Previously developed integrated design and optimal tuning methods are applied for developing the robust tuning method. Strict mathematical modeling of the multivariable system is formulated as a state-space equation. Identification processes of the servomechanism are conducted for mechanical servo models. An optimal tuning problem to minimize both the contour error and settling time is formulated as a nonlinear constrained optimization problem including the relevant controller parameters of the servo control system. Constraints such as relative stability, robust stability and overshoot, etc. are considered for the optimization. To verify the effectiveness of the proposed optimal tuning procedure, linear and circular motion experiments are performed on the xy-table. Experimental results confirm the control performance and robustness despite the variation of parameters of the mechanical subsystems.

Cosmetic Lateral Canthoplasty: Lateral Canthoplasty to Lengthen the Lateral Canthal Angle and Correct the Outer Tail of the Eye

  • Chae, Soo Wook;Yun, Byung Min
    • Archives of Plastic Surgery
    • /
    • 제43권4호
    • /
    • pp.321-327
    • /
    • 2016
  • There are many women who want larger and brighter eyes that will give a favorable impression. Surgical methods that make the eye larger and brighter include double eyelidplasty, epicanthoplasty, as well as lateral canthoplasty. Double eyelidplasty produces changes in the vertical dimension of the eyes, whereas epicanthoplasty and lateral canthoplasty create changes in the horizontal dimension of the eyes. Epicanthoplasty, a surgical procedure which enlarges the eye horizontally, is performed at the inner corner of the eye, whereas lateral canthoplasty enlarges the outer edge of the eye. In particular, if the slant of the palpebral fissure is raised and the horizontal dimension of the palpebral fissure is short, adjusting the slant of the palpebral fissure through lateral canthoplasty can achieve an enlargement of eye width and smoother features. Depending on the patient's condition, even better results can be achieved if this procedure is performed in conjunction with other procedures, such as double eyelid-plasty, epicanthoplasty, eye roll formation surgery, fat graft, and facial bone contouring surgery. In this paper, the authors will introduce in detail their surgical method for a cosmetic lateral canthoplasty that lengthens the lateral canthal angle and corrects the outer tail of the eyes, in order to ease the unfavorable impression.

구개 접근법에 의한 협골 축소 성형술 (REDUCTION MALARPLASTY THROUGH INTRAORAL APPROACH)

  • 우순섭;김명진;민병일
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권3호
    • /
    • pp.171-177
    • /
    • 1993
  • The prominent malar region has been recognized a sign of youth and beauty in caucasian who generally have a dolichocephalic and long face. But in the orients, especially Koreans who generally have a mesocephalic or brachycephalic face, it is considered an agressive, unesthetic facial appearance. So many patients require the shaving of prominent malar eminence and arch, and many methods of its reduction have been devised. For the exposure of malar complex, infraorbital skin incision, intraoral approach, preauricular approach, supraauricular scalp incision, and coronal approach have been used. And for the reduction of bony structure, direct shaving, contouring and repositioning of the malar complex after extirpation, and medially fracture of zygomatic arch have been used with its own merits. We performed the reduction malarplasty through intraoral approach. After two parallel oeteotomy at medial part of the zygomatic bone, the midsegment is removed. The posterior arch of zygoma was bended or green stick fractured. When more correction was required, the posterior arch was fractured medially through the step incision at skin. This method has a some advantages. Compared with the method for extirpation of malar complex, the infection rate is diminished, the resorption is small because of no free bone graft. And cheek drooping is prevented. Compared with the method of coronal approach, the surgical trauma is minimal. Now we report some cases of reduction malarplasty performed through intraoral approach and disscus the surgical technique and results.

  • PDF

삼차원 영상 모델링 및 삼차원 의료영상의 가시화에 관한 연구 (A Study on Three-Dimensional Image Modeling and Visualization of Three-Dimensional Medical Image)

  • 이건;권오봉
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제3권2호
    • /
    • pp.27-34
    • /
    • 1997
  • 3 차원 영상 모델링은 자동 시각적 검사와, 비파괴 검사분야에서 절실히 요구되고 있는 연구 분야이다. 또한 그것은 생의학연구, 의료, 수술계획과 정교성이 요구되는 중대한 수술 (안면 절개) 등에 매우 유용하다. 영상처리 및 분석 기술은 3 차원 의료 영상 정보의 질올 높여 주는데, 의료정보를 정확하고 빠르게 분석하는 일은 용이하지 않다. 본 논문에서는 향상된 3 차원 의료영상의 가시화를 위하여 사면체 분할법에 의한 모델링 방법을 제안한다. 이 방법에서는 트라이 베리에이트 구간별 선형 보간법이 구축된 사면체영역에 걸쳐 적용된다. 그리고, 등면, 색채 윤곽, 슬라이싱 등 가시화 방법들도 논의된다. 이것은 마칭큐브스 알고리즘으로 인해 제기되는 불확실한 경우가 발생하지 않고, 자료 감축의 효과도 가져올 수 있으므로 보다 정확하고 빠른 의료정보 분석에 기여할 수 있을 것으로 사료된다. 그리고, 자료 감축으로 인한 정확도의 감소가 발생할 경우에는 최소제곱을 바탕으로 한 사면체 세분할을 사용하여 보완할 수 있을 것으로 기대한다.

  • PDF

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

잠복이에서 고밀도 폴리에틸렌 삽입물(MEDPOR®)을 이용한 귀성형술 (Otoplasty with High Density Polyethylene Implant(MEDPOR®))

  • 이근철;권용석;허정;문주봉;김석권
    • Archives of Plastic Surgery
    • /
    • 제36권2호
    • /
    • pp.167-173
    • /
    • 2009
  • Purpose: The key points of treatment of cryptotia are the elevation of invaginated ear helix and the correction of deformed cartilage. Prevention of stabilized cartilage contouring from returning to the previous state is also important. The authors carried otoplasty by modified Onizuka's method or Ohmori's method that conchal cartilage graft or high density polyethylene implant(MEDPOR$^{(R)}$) graft served as fixation after spreading posterior aspect of adhered antihelix and a splint for prevention of recurrence of cartilage deformities. The aim of this study is to reveal the availability of the high density polyethylene implant(MEDPOR$^{(R)}$) graft for the correction of cryptotia. Methods: We have repaired 17 cryptotic deformities using cartilage graft from cavum of concha(12 cases) or high density polyethylene implant(5 cases) for correction of deformed cartilage. We investigate the operative time, complications, and satisfaction of postoperative ear shape on both autogenous cartilage graft group and high density polyethylene implant graft group. Results: There was 1 case of reinvagination on autogenous cartilage graft group. Implant exposure was occurred on high density polyethylene implant graft group, as 1 case. These were statistically no differences between autogenous cartilage graft group and high density polyethylene implant graft group to the satisfaction of ear shape. Conclusion: High density polyethylene implant(MEDPOR$^{(R)}$) present an alternative to autogenous material as they allow of fibrovascular ingrowth, leading to stability of the implant and decreased infection rates. The correction of deformed cartilage by using the high density polyethylene implant(MEDPOR$^{(R)}$) is a good option for the treatment of cryptotia.