• Title/Summary/Keyword: contouring method

Search Result 77, Processing Time 0.027 seconds

Assessment of the VOCs Concentration Using GIS Method of Seoul (GIS 기법을 활용한 서울시 VOCs 오염도평가에 관한 연구)

  • Park, Ki-Hark;Chung, Yong;Cho, Sung-Jun
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.2
    • /
    • pp.135-145
    • /
    • 2001
  • This study was conducted to investigate the practical using of Geographic Information System(GIS) technology which are computer-based systems that are used to store and manipulate geographic information on the air pollution control and management in the macro city. For this study 130 samples were corrected by passive sampler in Seoul (25 distincts) distributed by TM-coordinate during November in 1997 to January 1998, and analysed by GC/MSD for 16 VOCs e.g., toluene, benzene and display using Arc/view GIS(version 3.2, ESRI Inc, U.S.A) for windows. The most VOCs concentration distribution in November, 1997 was higher than that of January, 1998 except benzene and 1,1,2-trichroloethan, bromobenzene. And products of the distribution of VOCs concentration display using GIS technology was effective as well as other display methods(e.g., contouring method, pie or column chart, graduated symbols), especially in mapping and symbolization capabilities for spatial pollutant status evaluation were very effective than other display methods.

  • PDF

A Study on the Air Pollution Management Using GIS Method(I)-Focus on VOCs concentration of Seoul- (GIS 기법을 활용한 대기오염관리에 관한 연구(I)-서울시 VOCs 오염도를 중심으로-)

  • 박기학;조성준;유영대
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.100-107
    • /
    • 2001
  • On the planning for the systematic management and control of the air pollution display methods were used to evaluate the spatial pollutant concentration status. This study were conducted to investigate the practical using of Geographic Information System(GIS) technology on the air pollution control and management which were computer-based systems that were used to store and manipulate geographic information in the macro city. In this study 137 samples were corrected by passive samplers and analysed by GC/MSD for 16 VOCs in Seoul (25 distincts) distributed by TM-coordinate(2 km$\times$2km), and finally displayed by Arciew program(version 3.2, ESRI Inc, USA) for windows. The concentration of benzene and toluene showed high level in whole area of seoul area of Seoul and distribution of butylbenzen, trothroloetylene, stylen showed high level in whole area of Seoul except a few distincts and the distribution of isopropylbenzene, 1,2-dichroloethane showed higher level in core area than that of Kangnam and Kangbuk area. In conclusion, products of this study of using GIS technology apply on the spatial distribution of VOCs concentration was very effective than that of other methods(e.g., contouring concentration method, pie or column chart, graduated symbols), especially in mapping and symbolization of pollution status evaluation.

  • PDF

Generation Method of the Rectangular Grid Information for Finite Difference Model (유한차분모형을 위한 직사각형 격자정보 생성기법)

  • 정신택;조범준;김정대
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.3
    • /
    • pp.190-195
    • /
    • 2003
  • For many coastal problems, such as wave transformation, tidal circulation, sediment transports and diffusion phenomena, we resort to numerical techniques. The representative numerical techniques are the method of finite differences and finite elements. The approximate algebraic equations, referred to as finite difference equations(FDEs), are subsequently solved at discrete grid points within the domain of interests. Therefore, a set of grid points within the domain, as well as the boundaries of the domain, must be specified. The generation of grids for FDEs, with uniform spacing, is very simple compared to that of finite elements. However, within a very complex domain, there are few grid generation tools we can use conveniently. Unfortunately, most of the commercial grid generation programs are developed only for finite element method. In this paper, grid generation method using digitizer, with uniform rectangular spacing, are introduced in detail. Didger and Surfer programs by Golden Software are necessary to produce comparatively accurate and simple depth data.

The path of placement of a removable partial denture: a microscope based approach to survey and design

  • Mamoun, John Sami
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.76-84
    • /
    • 2015
  • This article reviews the topic of how to identify and develop a removable partial denture (RPD) path of placement, and provides a literature review of the concept of the RPD path of placement, also known as the path of insertion. An optimal RPD path of placement, guided by mutually parallel guide planes, ensures that the RPD flanges fit intimately over edentulous ridge structures and that the framework fits intimately with guide plane surfaces, which prevents food collecting empty spaces between the intaglio surface of the framework and intraoral surfaces, and ensures that RPD clasps engage adequate numbers of tooth undercuts to ensure RPD retention. The article covers topics such as the causes of obstructions to RPD intra-oral seating, the causes of food collecting empty spaces that may exist around an RPD, and how to identify if a guide plane is parallel with the projected RPD path of placement. The article presents a method of using a surgical operating microscope, or high magnification (6-8x or greater) binocular surgical loupes telescopes, combined with co-axial illumination, to identify a preliminary path of placement for an arch. This preliminary path of placement concept may help to guide a dentist or a dental laboratory technician when surveying a master cast of the arch to develop an RPD path of placement, or in verifying that intra-oral contouring has aligned teeth surfaces optimally with the RPD path of placement. In dentistry, a well-fitting RPD reduces long-term periodontal or structural damage to abutment teeth.

Optimal Tuning of a Ballscrew Driven Biaxial Servo System (외란관측기를 이용한 볼스크류 구동 2축 서보계의 최적튜닝)

  • Shin, Dong-Soo;Chung, Sung-Chong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.589-597
    • /
    • 2011
  • In this paper, optimal tuning of a cross-coupled controller linked with the feedforward controller and the disturbance observer is studied to improve contouring and tracking accuracy as well as robustness against disturbance. Previously developed integrated design and optimal tuning methods are applied for developing the robust tuning method. Strict mathematical modeling of the multivariable system is formulated as a state-space equation. Identification processes of the servomechanism are conducted for mechanical servo models. An optimal tuning problem to minimize both the contour error and settling time is formulated as a nonlinear constrained optimization problem including the relevant controller parameters of the servo control system. Constraints such as relative stability, robust stability and overshoot, etc. are considered for the optimization. To verify the effectiveness of the proposed optimal tuning procedure, linear and circular motion experiments are performed on the xy-table. Experimental results confirm the control performance and robustness despite the variation of parameters of the mechanical subsystems.

Cosmetic Lateral Canthoplasty: Lateral Canthoplasty to Lengthen the Lateral Canthal Angle and Correct the Outer Tail of the Eye

  • Chae, Soo Wook;Yun, Byung Min
    • Archives of Plastic Surgery
    • /
    • v.43 no.4
    • /
    • pp.321-327
    • /
    • 2016
  • There are many women who want larger and brighter eyes that will give a favorable impression. Surgical methods that make the eye larger and brighter include double eyelidplasty, epicanthoplasty, as well as lateral canthoplasty. Double eyelidplasty produces changes in the vertical dimension of the eyes, whereas epicanthoplasty and lateral canthoplasty create changes in the horizontal dimension of the eyes. Epicanthoplasty, a surgical procedure which enlarges the eye horizontally, is performed at the inner corner of the eye, whereas lateral canthoplasty enlarges the outer edge of the eye. In particular, if the slant of the palpebral fissure is raised and the horizontal dimension of the palpebral fissure is short, adjusting the slant of the palpebral fissure through lateral canthoplasty can achieve an enlargement of eye width and smoother features. Depending on the patient's condition, even better results can be achieved if this procedure is performed in conjunction with other procedures, such as double eyelid-plasty, epicanthoplasty, eye roll formation surgery, fat graft, and facial bone contouring surgery. In this paper, the authors will introduce in detail their surgical method for a cosmetic lateral canthoplasty that lengthens the lateral canthal angle and corrects the outer tail of the eyes, in order to ease the unfavorable impression.

REDUCTION MALARPLASTY THROUGH INTRAORAL APPROACH (구개 접근법에 의한 협골 축소 성형술)

  • Woo, Soon-Seop;Kim, Myung-Jin;Min, Byong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.171-177
    • /
    • 1993
  • The prominent malar region has been recognized a sign of youth and beauty in caucasian who generally have a dolichocephalic and long face. But in the orients, especially Koreans who generally have a mesocephalic or brachycephalic face, it is considered an agressive, unesthetic facial appearance. So many patients require the shaving of prominent malar eminence and arch, and many methods of its reduction have been devised. For the exposure of malar complex, infraorbital skin incision, intraoral approach, preauricular approach, supraauricular scalp incision, and coronal approach have been used. And for the reduction of bony structure, direct shaving, contouring and repositioning of the malar complex after extirpation, and medially fracture of zygomatic arch have been used with its own merits. We performed the reduction malarplasty through intraoral approach. After two parallel oeteotomy at medial part of the zygomatic bone, the midsegment is removed. The posterior arch of zygoma was bended or green stick fractured. When more correction was required, the posterior arch was fractured medially through the step incision at skin. This method has a some advantages. Compared with the method for extirpation of malar complex, the infection rate is diminished, the resorption is small because of no free bone graft. And cheek drooping is prevented. Compared with the method of coronal approach, the surgical trauma is minimal. Now we report some cases of reduction malarplasty performed through intraoral approach and disscus the surgical technique and results.

  • PDF

A Study on Three-Dimensional Image Modeling and Visualization of Three-Dimensional Medical Image (삼차원 영상 모델링 및 삼차원 의료영상의 가시화에 관한 연구)

  • Lee, Kun;Gwun, Oubong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.3 no.2
    • /
    • pp.27-34
    • /
    • 1997
  • 3-D image modeling is in high demand for automated visual inspection and non-destructive testing. It also can be useful in biomedical research, medical therapy, surgery planning, and simulation of critical surgery (i.e. cranio-facial). Image processing and image analysis are used to enhance and classify medical volumetric data. Analyzing medical volumetric data is very difficult In this paper, we propose a new image modeling method based on tetrahedrization to improve the visualization of three-dimensional medical volumetric data. In this method, the trivariate piecewise linear interpolation is applied through the constructed tetrahedral domain. Also, visualization methods including iso-surface, color contouring, and slicing are discussed. This method can be useful to the correct and speedy analysis of medical volumetric data, because it doesn't have the ambiguity problem of Marching Cubes algorithm and achieves the data reduction. We expect to compensate the degradation of an accuracy by using an adaptive sub-division of tetrahedrization based on least squares fitting.

  • PDF

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.50 no.2
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

Otoplasty with High Density Polyethylene Implant(MEDPOR®) (잠복이에서 고밀도 폴리에틸렌 삽입물(MEDPOR®)을 이용한 귀성형술)

  • Lee, Keun-Cheol;Kwon, Yong-Seok;Heo, Jung;Moon, Ju-Bong;Kim, Seok-Kwun
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.167-173
    • /
    • 2009
  • Purpose: The key points of treatment of cryptotia are the elevation of invaginated ear helix and the correction of deformed cartilage. Prevention of stabilized cartilage contouring from returning to the previous state is also important. The authors carried otoplasty by modified Onizuka's method or Ohmori's method that conchal cartilage graft or high density polyethylene implant(MEDPOR$^{(R)}$) graft served as fixation after spreading posterior aspect of adhered antihelix and a splint for prevention of recurrence of cartilage deformities. The aim of this study is to reveal the availability of the high density polyethylene implant(MEDPOR$^{(R)}$) graft for the correction of cryptotia. Methods: We have repaired 17 cryptotic deformities using cartilage graft from cavum of concha(12 cases) or high density polyethylene implant(5 cases) for correction of deformed cartilage. We investigate the operative time, complications, and satisfaction of postoperative ear shape on both autogenous cartilage graft group and high density polyethylene implant graft group. Results: There was 1 case of reinvagination on autogenous cartilage graft group. Implant exposure was occurred on high density polyethylene implant graft group, as 1 case. These were statistically no differences between autogenous cartilage graft group and high density polyethylene implant graft group to the satisfaction of ear shape. Conclusion: High density polyethylene implant(MEDPOR$^{(R)}$) present an alternative to autogenous material as they allow of fibrovascular ingrowth, leading to stability of the implant and decreased infection rates. The correction of deformed cartilage by using the high density polyethylene implant(MEDPOR$^{(R)}$) is a good option for the treatment of cryptotia.