• Title/Summary/Keyword: continuous wave

Search Result 793, Processing Time 0.059 seconds

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Recent Fertility and its Policy Implications (최근의 출산력과 정책적 함의)

  • Park, Kyung-Ae
    • Korea journal of population studies
    • /
    • v.30 no.3
    • /
    • pp.137-156
    • /
    • 2007
  • Total fertility rate (TFR) increased from the lowest 1.08 in 2005 to 1.13 in 2006, and a debate is made whether the increase is temporary or continuous as a result of various pro-natal policies. This study intends to explore policy implications revealed in recent fertility change using vital statistics. For this purpose, tempo-adjusted fertility rate by birth order, fertility rate by age of mother and birth order, age-specific fertility for married, and age-specific divorce rate for married are analyzed. The increase of TFR and births for 2006 is largely due to increase of first births at early thirties with slowdown of delayed first marriage and first child birth. The increase of female population (the third wave effect of baby boom) and first marriages of late twenties in 2006 and 2007 would lead to increase of fertility during 2007-2008. But further increase is uncertain because of the decrease trend of marital fertility and increase trend of never-married for twenties. TFRs for first and second births reduced rapidly, while TFRs for third and above births showed no changes, and second births were largely affected by tempo adjustment of fertility. Thus, constructing social environment for first and second births is more effective and necessary than encouraging third births. In addition, social responsibility of child care, child-women health issues due to delayed births, and the need for multi-cultural family support system are discussed.

Treatment of Gingival Irritation Fibroma Using $CO_2$ Laser (이산화탄소 레이저($CO_2$ laser)를 이용한 치은에 발생한 자극성 섬유종의 치료)

  • Choi, Young-Chan;Park, Ju-Hyun;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.2
    • /
    • pp.119-122
    • /
    • 2010
  • Carbondioxide($CO_2$) laser is one of the most widely employed lasers in oral soft tissue surgery because of its excellent affinity for water based soft tissues. It has some inherent advantages such as hemostasis, less postoperative swelling, reduction of bacterial population at surgical site, less need for suturing, less scarring, and less postoperative pain compared to conventional surgical therapies including the use of scalpel, diathermy, cryotherapy and electrosurgery. A 30-years-old male was presented with gingival swelling. Clinical examination revealed a well?defined pedunculated fibrotic mass on the buccal gingiva near right maxillary 1st molar. In radiographic examination, no remarkable abnormality was seen. Excisional biopsy was performed with $CO_2$ laser (continuous wave mode, 4.0W). Histological diagnosis was "Irritation fibroma". $CO_2$ laser has advantages those are suitable for surgical treatment of intraoral lesion. If appropriate training and experience are provided, the dentist would be able to manage intraoral lesions more efficiently and successfully with the use of the $CO_2$ laser.

IN VITRO STUDY ON APICAL SEAL AND SEM MORPHOLOGY IN CANALS FILLED WITH RESIN-BASED ROOT CANAL SEALER AND SELF-ETCHING PRIMER (SELF-ETCHING PRIMER와 레진계 근관 SEALER 사용시 근관벽의 형태와 치근단 근관밀폐에 대한 실험적 연구)

  • Kang, Sam-Hee;Park, Dong-Sung;You, Heyon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.543-549
    • /
    • 2000
  • Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.

  • PDF

Extended Target State Vector Estimation using AKF (적응형 칼만 필터를 이용한 확장 표적의 상태벡터 추정 기법)

  • Cho, Doo-Hyun;Choi, Han-Lim;Lee, Jin-Ik;Jeong, Ki-Hwan;Go, Il-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.6
    • /
    • pp.507-515
    • /
    • 2015
  • This paper proposes a filtering method for effective state vector estimation of highly maneuvering target. It is needed to hit the point called 'sweet spot' to increase the kill probability in missile interception. In paper, a filtering method estimates the length of a moving target tracked by a frequency modulated continuous wave (FMCW) radar. High resolution range profiles (HRRPs) is generated from the radar echo signal and then it's integrated into proposed filtering method. To simulate the radar measurement which is close to real, the study on the properties of scattering point of the missile-like target has been conducted with ISAR image for different angle. Also, it is hard to track the target efficiently with existing Kalman filters which has fixed measurement noise covariance matrix R. Therefore the proposed method continuously updates the covariance matrix R with sensor measurements and tracks the target. Numerical simulations on the proposed method shows reliable results under reasonable assumptions on the missile interception scenario.

Shape Deformation Monitoring for VLBI Antenna Using Close-Range Photogrammetry and Total Least Squares (근접사진측량과 Total Least Squares를 활용한 VLBI 안테나 형상 변형 모니터링 방안 연구)

  • Kim, Hyuk Gil;Yun, Hong Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.1
    • /
    • pp.99-107
    • /
    • 2016
  • In order to maintain the precise positioning accuracy of the VLBI system, the shape deformation found in antenna structure should be monitored. In fact, reduced the antenna gaining of an electromagnetic wave reception from the Quasar has been particularly expected due to the shape deformation of main reflector in VLBI antenna. Therefore, the importance of shape deformation monitoring for the main reflector has been significantly increased. The main reflector has come out as the high potential for deformation in the VLBI structure. The fact has led us to investigate the monitoring system for the main reflector based on the efficient algorithm in accordance with the close-range photogrammetry, which of expecting to be utilized as the continuous and automated monitoring system for the structure deformation in the near future. Ten fitting lines were estimated with the TLS for feature points of distributed in all directions from the main reflector. The resultant intersection point of estimated fitting lines was calculated by using the nearest point calculation algorithm, based on those non-intersection lines. Following to the intuitive basis for the time series analysis, the results was able to provide the calculation of numerical variation in the intersection point, which is represented in 3-axis,; that we are expecting to open the way for predicting a deformation rate as well as deformation direction

X-Band FMCW RADAR Signal Processing for small ship (소형선박용 X-Band FMCW 레이더 신호처리부 설계 및 구현)

  • Kim, Jeong-Yeon;Chong, Kil-To;Kim, Tae-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3121-3129
    • /
    • 2009
  • Conventional marine radar systems utilize pulse radar which is capable of high-power transmissions and is effective for remote detection purposes. A pulse radar is most commonly used on medium or large vessels due to its expensive installation and maintenance costs. I propose the use of a Frequency Modulated Continuous Wave (FMCW) radar system operated at low-power and high-resolution instead of the conventional pulse-radar based system. The transmitted and received signals of the FMCW radar system were theoretically analyzed and radar signal processing design and simulation experiments were performed to detect the range and speed. Intermediate Frequency (IF) signal mixed with virtual transmit and receive signals were generated to perform FMCW radar signal processing simulations where the IF signal underwent noise reduction through a lowpass filter. The maximum frequency was derived through the sample interval of the FFT size instead of using A/D converter. This maximum frequency was used to get the frequency range and frequency speed which were in turn used to calculate the range and speed. The virtual beat frequency generated using MATLAB is utilized to analyze the beat frequency used in the actual FMCW radar system signal processing. The differences in the range and speed of the beat frequency signals are processed and analyzed.

Continuously Recycling Sterilization of Yakju(Rice Wine) Using Pulsed Electric Fields (고전장펄스를 이용한 약주의 연속 재순환 살균)

  • Kim, Su-Yeon;Mok, Chul-Kyoon;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.410-415
    • /
    • 1999
  • Yakju was sterilized with high-voltage pulses of short time of a continuous pulsed electric field (PEF) system. The initial microbial counts of Yakju were $2.2{\times}10^{5}$ CFU/mL for total aerobes. The pH, acidity and electric conductivity of Yakju were 3.82, 0.37% and 1.24 mS/cm, respectively. Yakju was treated with exponential-wave formed electric pulses of 100 Hz for $0{\sim}4000{\mu}s$ under the field strength of $20{\sim}35\;kV/cm$. The lethal effect of electric fields on microorganisms was resulted from the breakdown of the cell membrane induced by the transmembrane electric potential. The critical values of the external field for the sterilization were 16.0 kV/cm for total aerobes. Logarithmic survival rates decreased linearly at low electric field strength, but curvilinearly at high electric field strength with treatment time. The sterilization of Yakju was more largely affected by the electric field strength than by the treatment time. Any changes in pH, acidity, and the growth of microorganisms were not found in the PEF treated Yakju during the storage at both $4^{\circ}C\;and\;30^{\circ}C$.

  • PDF

Design and Fabrication of butt-coupled(BT) sampled grating(SG) distributed bragg reflector(DBR) laser diode(LD) using planar buried heterosture(PBH) (저 전류 및 고 효율로 동작하는 양자 우물 매립형 butt-coupled sampled grating distributed bragg reflector laser diode 설계 및 제작)

  • Oh Su Hwan;Lee Chul-Wook;Kim Ki Soo;Ko Hyunsung;Park Sahnggi;Park Moon-Ho;Lee Ji-Myon
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.469-474
    • /
    • 2004
  • We have fabricated and designed wavelength-tunable sampled grating distributed Bragg reflector laser diodes(SGDBR-LD) by using, for the first time, planar buried heterostructures(PBH). The diodes have low threshold current values and high-performance of laser operation. Growth condition using metal organic chemical vapor deposition(MOCVD) was optimized for the formation of a good butt-coupling at the interface. A maximum output power of the fabricated device was 20 mW under 200 mA continuous wave(CW) operation at $25^{\circ}C$. Average threshold current and voltage were 12 mA and 0.8 V, approximately. This output power is higher than those of ridge waveguide(RWG) and buried ridge stripe(BRS) structures by amounts of 9 mW and 13 mW, respectively. We obtained a tuning range of 44.4nm which is well matched with the target value of our design. The side mode suppression ratio of more than 35 dB was obtained for the whole tuning range. Optical output power variation was less than 5 dB, which is 4 dB smaller than that of RWG structures.

Efficient Second Harmonic Generation of a High-power Yb-doped Fiber MOPA Incorporating MgO:PPSLT (MgO:PPSLT를 이용한 고출력 Yb 광섬유 레이저 빔의 고효율 이차조화파 변환)

  • Song, Seungbeen;Park, Eunji;Park, Jong Sun;Oh, Yejin;Jeong, Hoon;Kim, Ji Won
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.3
    • /
    • pp.142-147
    • /
    • 2020
  • In this paper, we report highly efficient second harmonic generation of continuous-wave Yb fiber lasers incorporating a periodically poled LiTaO3 device (MgO:PPSLT) as a frequency converter. The seed laser output from a Yb fiber master oscillator using a Fabry-Perot feedback cavity was amplified in a Yb fiber amplifier stage, yielding 28.5 W of linearly polarized output at 1064 nm in a beam with beam quality, M2, of ~1.07. Second harmonic generation was achieved by passing the laser beam through MgO:PPSLT. Under optimized conditions, we obtained 11.1 W of green laser output at 532 nm for an incident signal power of 25.0 W at 1064 nm, corresponding to a conversion efficiency of 44.4%. The detailed investigation to find the optimized operating conditions and prospects for further improvement are discussed.