• Title/Summary/Keyword: continuous contact

Search Result 374, Processing Time 0.025 seconds

Newly Developed BioDegradable Mg Alloys and Its Biomedical Applications

  • Seok, Hyeon-Gwang;Kim, Yu-Chan;Yang, Gui Fu;Cha, Pil-Ryeong;Jo, Seong-Yun;Yang, Seok-Jo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.55.2-55.2
    • /
    • 2012
  • Intensive theoretical and experimental studies have been carried out at Korean Institute of Science and Technology (KIST) on controlling the bio absorbing rate of the Mg alloys with high mechanical strength through tailoring of electrochemical potential. Key technology for retarding the corrosion of the Mg alloys is to equalize the corrosion potentials of the constituent phases in the alloys, which prevented the formation of Galvanic circuit between the constituent phases resulting in remarkable reduction of corrosion rate. By thermodynamic consideration, the possible phases of a given alloy system were identified and their work functions, which are related to their corrosion potentials, were calculated by the first principle calculation. The designed alloys, of which the constituent phases have similar work function, were fabricated by clean melting and extrusion system. The newly developed Mg alloys named as KISTUI-MG showed much lower corrosion rate as well as higher strength than previously developed Mg alloys. Biocompatibility and feasibility of the Mg alloys as orthopedic implant materials were evaluated by in vitro cell viability test, in vitro degradation test of mechanical strength during bio-corrosion, in vivo implantation and continuous observation of the implant during in vivo absorbing procedures. Moreover, the cells attached on the Mg alloys was observed using cryo-FIB (focused ion beam) system without the distortion of cell morphology and its organ through the removal of drying steps essential for the preparation of normal SEM/TEM samples. Our Mg alloys showed excellent biocompatibility satisfying the regulations required for biomedical application without evident hydrogen evolution when it implanted into the muscle, inter spine disk, as well as condyle bone of rat and well contact interface with bone tissue when it was implanted into rat condyle.

  • PDF

Preliminary Study of the Leaching Resistance of Boron from Borate Treated Wood by the Dual Treatment with Water-Repellent Preservative and Methyl Metacrylate (방부성(防腐性) 발수제(撥水劑)와 methyl metacrylate 이중처리(二重處理)에 의(依)한 붕소화합물(硼素化合物) 처리재(處理材)로부터 붕소(硼素)의 용탈(溶脫) 저항성(抵抗性)에 관(關)한 기초연구(基礎硏究))

  • Kim, Gyu-Hyeok;Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.13-18
    • /
    • 1994
  • Sapwood samples of pitch pine were treated with disodium octaborate alone by dip-diffusion, or in combination with water-repellent preservative(WRP) and methyl metacrylate(MMA). Treated samples were subjected to an accelerated leaching test for determining the improvement of leaching resistance and to soft rot and mold tests for evaluating the increase in bioefficacy, due to the addition of WRP and MMA applied as a second treatment. The addition of WRP and MMA retarded leaching of boron to some extent from treated samples and this retardation can be explained by improved water repellency of WRP and MMA treated samples. Borate /WRP and borate /MMA systems will not qualify borate treated wood for ground and fresh water contact use but may improve performance of borate treated wood in above-ground applications not subjected to continuous wetting conditions. Bioefficacy against soft rot fungi and mold fungi was improved by a second treatment with WRP. However, improvement in the performance of borate /MMA systems was not observed. Considering improvement in both resistance of leaching and bioefficacy against micro fungi by the treatment of WRP and MMA, simultaneously, the dual treatment of borate treated wood by MMA containing co-biocides might be believed as an ideal treatment system.

  • PDF

Reduction of Length of Stay in Emergency Room by Using Critical Pathway for Stroke Patients (Critical pathway 적용을 통한 급성 뇌졸중 환자의 응급실 체류시간 단축 효과)

  • Yun, Yeo-Ok;Kim, Min-Young;Kim, Woo-Jeong;Kang, Young-Joon;Park, Ju-Ok;Park, Kyung-Hye
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.1
    • /
    • pp.66-73
    • /
    • 2011
  • Purpose: The purpose of this study was to demonstrate effects of a critical pathway (CP) for stroke patients seen in emergency rooms (ER). Method: The CP developed by the CP committee consisted of 8 criteria: behavior of doctors and nurses, laboratory tests, Image testing, medication, treatment, activity, and nutrition. According to application of CP, a control group (n=17) and experimental group (n=17) were defined. Time was checked by the electronic medical records. Result: Use of CP for stroke patients in the ER, resulted in a decreased length of stay in ER (t=2.341, p=.026), and time required for image testing (t=2.623, p=.021), and an increased number of patients using rtPA ($x^2$=4.802, p=.049). Time required for neurology doctor contact, for neurology doctor to see patient in the ER, and for report of blood tests decreased, but there were no statistical significance. Conclusion: Quick responses are most important in the ER, so CP for these patients is a very effective patient management tool. To reduce delay in stroke diagnosis, continuous education programs for similar symptoms are necessary. CPs for other patients in the ER should be developed, and studies on cost and satisfaction, as well as length of stay, should be done.

Recent Advances in the Ink-Jet Printing Ceramic Tile Using Colorant Ceramic-ink (고화도 발색세라믹잉크를 이용한 잉크젯프린팅 도자타일 연구동향)

  • Kim, Jin-Ho;Noh, Hyung-Goo;Kim, Ung-Soo;Cho, Woo-Suk;Choi, Jung-Hoon;Lee, Yong-Ouk
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.498-503
    • /
    • 2013
  • Over the past decade, the feasibility of using ink-jet printing for the decoration of porcelain tiles has been explored, and significant advances have been made regarding the technologies underlying printing system and materials. An ink-jet printing system for porcelain tiles has many advantages compared with a conventional printing system, including the following: (1) it is a digital process; (2) it uses non-contact printing; (3) it allows random image generation; (4) it is a highly efficient process (reduced production cost); (5) it offers massive and continuous production; and (6) it uses inorganic pigment colorants. For these reasons, ink-jet printing systems for porcelain tiles have been commercialized and are at present rapidly spreading toceramics-leading countries such as Spain, Italy, China and Japan. We also developed a proprietary system involving a piezo-electric drop-on-demand method and an ink-circulation step. The resolution of this system is greater than 360 dpi after a heat treatment and the maximum printable width is 600 mm, even when setting the printing head unit with four digital colors (cyan, magenta, yellow, and black). In addition, we systematically developed ceramic colorant-containing inks and tile-printing technology applicable to our ink-jet printing system.

The Effect of Shoe Lift of the Paretic Limb on Gait Patterns in Hemiplegics (환측 신발 높이기가 편마비 환자의 보행 특성에 미치는 영향)

  • Yoon, Jung-Gyu;Park, Jeong-Mee;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.83-96
    • /
    • 2002
  • The purpose of this study was to determine the effect of lift to the shoe of the affected limb on gait patterns in subjects with hemiplegia. The subjects of this study were 18 post-stroke hemiplegics. For the study, insole of the paretic side was lifted 10mm higher, and duration of static weight bearing, dynamic weight bearing and stance phase were measured from one cycle of the gait, before and after the lift application. For the measurement of carry-over effect of lift, we got data of those three items prior to and 3 weeks after lift application and 3 days after removal of the lift. Static weight bearing was significantly increased both just after and continuous application of lift for 3 weeks than before. Dynamic weight bearing was significantly decreased in heel contact and footflat phases only when just after application of the lift, without any change after 3 weeks application. In heel-off phase, dynamic weight bearing did not show any significant difference between before and just after application of lift whereas significantly decreased after 3 weeks application. Duration of stance phase was not changed among anytime of application. According to this study, lift applied to the shoe of the peretic limb was effective in inducing static weight bearing in the paretic limb, but did not significantly effect dynamic weight bearing on gait patterns. This study suggests that symmetry, induced by shoe lift applied to the paretic limb, could help correct abnormal posture that would be caused in standing and prevent development of abnormal muscle tone in subjects with hemiplegia caused by unilateral stroke.

  • PDF

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

Intelligent Control of a Virtual Walking Machine for Virtual Reality Interface (가상현실 대화용 가상걸음 장치의 지능제어)

  • Yoon, Jung-Won;Park, Jang-Woo;Ryu, Je-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.926-934
    • /
    • 2006
  • This paper proposes intelligent control of a virtual walking machine that can generate infinite floor for various surfaces and can provide proprioceptive feedback of walking to a user. This machine allows users to participate in a life-like walking experience in virtual environments with various terrains. The controller of the machine is implemented hierarchically, at low-level for robust actuator control, at mid-level fur platform control to compensate the external forces by foot contact, and at high-level control for generating walking trajectory. The high level controller is suggested to generate continuous walking on an infinite floor for various terrains. For the high level control, each independent platform follows a man foot during the swing phase, while the other platform moves back during single stance phase. During double limb support, two platforms manipulate neutral positions to compensate the offset errors generated by velocity changes. This control can, therefore, satisfy natural walking conditions in any direction. Transition phase between the swing and the stance phases is detected by using simple switch sensor system, while human foot motions are sensed by careful calibration with a magnetic motion tracker attached to the shoe. Experimental results of walking simulations at level ground, slope, and stairs, show that with the proposed machine, a general person can walk naturally on various terrains with safety and without any considerable disturbances. This interface can be applied to various areas such as VR navigations, rehabilitation, and gait analysis.

Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables (지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석)

  • Bae J. H.;Kim D. K.;Kim K. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.26-32
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power Therefore, there has been and still is a growing concern(safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline, especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion limitation of safety voltage and analysis of induction voltage.

  • PDF

Investigation into the Thermal Stability of Fluoropolymer Coating for Heat-Resistant Application (내열성 불소수지 코팅막의 열 안정성에 관한 연구)

  • Cho, Hey-Jin;Ryu, Ju-Hwan;Byun, Doo-Jin;Choi, Kil-Yeong
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.96-101
    • /
    • 2005
  • Fluoropolymer of PTFE and PFA etc. is a heat resistance polymeric material that it is known as that maximum continuous use temperature reaches for 260 $^{\circ}C$. It was observed that these polymers had the enough thermal stability so enough that it was kept by thermal aging of 280 $^{\circ}C$/7 weeks too in this study. However, such thermal stability means that bulk material property is kept such as mechanical strength, melting point and initial pyrolysis temperature etc. If these polymers are evaluate by coating property such as surface contact angle, surface morphology, surface scratch, thing that heat resistance is not enough was confirmed in this study. Thermal aging of flouropolymer coating was achieved by gear aging oven that the exchange rate of air was controlled, and the analysis results were indicating serious damage of surface morphology and adhesive strength on metal substrate.

Evaluation on Resistance Spot Weldability and Nugget Formation of Surface Roughness Treated Steel Sheet (표면조도 특성에 따른 저항 점 용접성 평가 및 너깃 형성 고찰)

  • Kim, Ki-Hong;Choi, Yung-Min;Kim, Young-Seok;Rhym, Young-Mok;Yu, Ji-Hun;Kang, Nam-Hyun;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.26 no.5
    • /
    • pp.79-89
    • /
    • 2008
  • With the increased use of surface textured steel sheet in body-in-white assembly, resistance spot weldability of these steels is considered to be an important subject. This study evaluated nugget formation and weldability by measuring dynamic resistance with various weld pressure, current, and weld time for steel sheet with two different surface roughnesses. The surface roughness for T-H steel ($R_{a}=1.70\;{\mu}m$) was higher than that for T-L steel ($R_{a}=1.33\;{\mu}m$), and resulted in increased contact resistance and heating for T-H steel spot welding. Therefore, at low weld current and weld cycle ranges, the T-H steel showed better weldability over the T-L steel. The evaluations of weld interface showed that the fusion zone in the T-H steel sheet was continuous in contrast to discontinuous fusion zone for T-L steel sheet at the same welding conditions. A comparison of dynamic resistance and tensile-shear strength (TSS) between T-H and T-L steel sheet suggested that high surface roughness provided larger heating at early cycle of welding and larger TSS.