• Title/Summary/Keyword: continuous band

Search Result 286, Processing Time 0.021 seconds

Interior Noise Characteristics in Japanese, Korean and Chinese Subways

  • Soeta, Yoshiharu;Shimokura, Ryota;Jeon, Jin Yong;Lee, Pyoung Jik
    • International Journal of Railway
    • /
    • v.6 no.3
    • /
    • pp.120-124
    • /
    • 2013
  • The aim of this study was to clarify the characteristics of interior noise in Japanese, Korean, and Chinese subways. The octave-band noise levels, A-weighted equivalent continuous sound pressure level ($L_{Aeq}$) and parameters extracted from interaural cross-correlation/autocorrelation functions (ACF/IACFs) were analyzed to evaluate the noise inside running train cars quantitatively and qualitatively. The average $L_{Aeq}$ was 72-83 dBA. The IACF/ACF parameters of the noise showed variations in their values, suggesting they are affected by the characteristics of the trains running, wheel-rail interaction, and cross-section of the tunnels.

Variable Speed Drives of Induction Motor for Traction Application with Modified Sliding Mode Control

  • Ryoo, Hong-Je;Kim, Jong-Soo;Rim, Geun-Hie;Dragos Ovidiu Kisck;Won, Chung-Yuen
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.62-68
    • /
    • 2001
  • In this paper it is proposed an advanced modified sliding mode control of a rotor field oriented control of induction motor. The application of this unconventional control has very good results, such as disturbance rejection and nice dynamic properties. Stability can be guaranteed even in the worst situation. A conventional "sliding mode" controller is characterised by fast switching control signal, which causes the chattering of the drive system. To overcome this problem, a modified law is used, by introducing a hysteresis band and a continuous control, which modifies the conventional law. The control is accomplished with dual TMS320C44 floating-point digital signal processor. The validity of the proposed method was verified by experiment on the propulsion system simulator, used for the development of Korean High-Speed Railway Train(KHSRT).in(KHSRT).

  • PDF

Statistic Pattern Analysis of HFPD According to Applied Stress (인가 스트레스에 따른 HFPD의 통계적 패턴해석)

  • Kim, Duck-Keun;Lee, Eun-Suk;Jung, Young-Ill;Lim, Jang-Seub;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.18-22
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A Study on the Sensitivities Characteristics in a PD and a HFPD (PD 측정과 HFPD의 감도특성에 관한 연구)

  • Lim, Jang-Seob;Kim, Duck-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.29-32
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires on-line & on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and PD/HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Aluminum particle ignition characteristics at high pressure condition up to 2 GPa (최대 2 GPa 고압 환경에서 알루미늄 입자의 점화 특성 연구)

  • Lee, Kyung-Cheol;Taira, Tsubasa;Koo, Goon Mo;Lee, Jae Young;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.5-8
    • /
    • 2013
  • The ignition of aluminum particles under high pressure and temperature conditions is studied. The laser ablation method is used to generate aluminum particles exposed to pressures ranging between 0.35 and 2.2 GPa. A continuous wave $CO_2$ laser is then used to heat surface of the aluminum target until ignition is achieved. We confirm ignition by a spectroscopic analysis of AlO vibronic band of 484 nm wavelength. The radiant temperature is measured with respect to various pressures for tracing of required heating energy for ignition. Then the ignition temperature is deduced from the radiant temperature using the thermal diffusion equation. The established ignition criteria for corresponding temperature and pressure can be used in the modeling of detonation behavior of heavily aluminized high explosives or solid propellants.

  • PDF

Applied Technology of FRP Single Pole for Power Distribution Line (배전용 지지물의 FRP 적용 기술)

  • 박기호;조한구;한동희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.79-81
    • /
    • 2000
  • Outdoor insulation of overhead distribution lines with wood, concrete and steel pole has been safety under various environmental conditions including contamination, moisture condensation, rain and lightning overvoltages. In this paper introduce to FRP technology of the power distribution single pole. FRP pole has been used very much as high strength material for insulators because of its high strength and good insulation properties. In addition, FRP pole was made by filament winding method. In a filament winding process, a band of continuous resin-impregnated rovings or monofilaments is wrapped around a rotating mandrel and cured to produce axisymmetric hollow parts.

  • PDF

Development of an Ambulatory Wearable System for Continuous Patient Monitoring (휴대용 심전도 모니터링 계측 시스템 개발에 관한 연구)

  • Park, Chan-Won;Jeon, Chan-Min
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.920-923
    • /
    • 2003
  • An wearable electrocardiogram (ECG) monitoring system is a widely used non-invasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we have a portable ECG monitoring system with conductive fiber which was characterized by the small-size and the low power consumption. The system consists of conductive fibers, one-chip microcontroller, ECG preprocessing circuit, and monitoring software to be able to record and analyze in PC. ECG preprocessing circuit is made of pre-amplifier with gain of 10, band-pass filter with bandwidth of 0.5-120Hz and 2.5V offset circuit for A/D conversion. ECG signals obtained by sensor are included with corrupted noises such as a baseline wandering, 60 Hz power noise and interference noise by body movement. For cancellation corrupted noises in signals obtained by conductive fiber, we used the wavelet decomposition of wavelet transforms in MATLAB toolbox.

  • PDF

Laser irradiation effect of electrophoretically-coated low-voltage phosphor for the application of Field Emission Display

  • 서도석;송병권;김채옥;남창우;홍진표
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.152-152
    • /
    • 2000
  • 차세대 평판 디스플레이로 주목박고 있는 FED는 현재 저전압 환경에서 기존의 CRT와 비슷한 해상도와 밝기를 얻지 못하고 있다. 이는 형광체 입자의 표면에 존재하는 결함, 오염, band - bonding과 같은 비발광층과 제조공정 중에 산화되거나 공기중에 노출되어 막 표면이 쉽게 오염되기 때문이다. 따라서 본 연구에서는 전기영동법으로 제작된 형광체의 효율 향상을 위해 레이저 표면 처리효과를 연구하였다. 실험에 사용한 레이저 표면처리 방법은 Nd:YAG pulse(355nm), continuous laser를 이용하였으며 레이저 power와 처리 시간을 변화시키면서 실시하였다. 형광체 막의 표면 두께 측정을 위해 Scanning Electron Microscopy(SEM), 처리된 막의 발광세기를 비교 분석하기 위해 Photoluminescence(PL), Cathodoluminescence(CL) intensity를 측정하였다.

  • PDF

Frequency Stabilization of Femtosecond Lasers for Dimensional Metrology (거리 및 형상 측정을 위한 펨토초 레이저의 주파수 안정화)

  • Kim Young-Jin;Jin Jong-Han;Kim Seung-Woo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.188-191
    • /
    • 2005
  • A common feature in various methods of optical interferometry for absolute distance measurements is the use of multiple monochromatic light components either in sequence or in parallel at the same time. Two or multiple wavelength synthesis has been studied though its performance is vulnerable to the frequency instability of the light source. Recently continuous frequency modulation is considered a promising method with availability of wide band tunable diode lasers, which also have frequency instability errors. We can lock frequencies of these third-party light sources to the modes of the femtosecond laser which is stabilized to the precision of the standard radio frequency. To this end, we have stabilized all the modes of the femtosecond laser to the atomic frequency standard by using powerful tools of frequency-domain laser stabilization.

  • PDF

Benchmark Calculations of Lattice Codes for the Doppler Coefficient of MOX Fuel

  • Shin, Ho-Cheol;Bae, Sung-Man;Kim, Yong-Bae;Lee, Sang-Hee
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.46-51
    • /
    • 1996
  • In this study we calculate the infite multiplication factors ($k_{\infty}$) and the Doppler temperature coefficients (DTC) of two mixed-oxide (MOX) fuel rods with different plutonium contents by using PHOENIX-P, HELIOS and CASMO-3 codes. The results were compared against the reference values obtained by MCNP-3A continuous-energy Monte Carlo code. The purpose of this study is to benchmark the accuracy of these lattice codes. The PHOENIX-P's Doppler coefficients calculated were in good agreement with the MCNP results within the Monte-Carlo uncertainty band which is in the order of $\pm$ 10% for the Doppler coefficients..

  • PDF