• 제목/요약/키워드: contamination warning system

검색결과 12건 처리시간 0.024초

차선 이탈 경고 시스템의 성능 검증을 위한 가상의 오염 차선 이미지 및 비디오 생성 방법 (Virtual Contamination Lane Image and Video Generation Method for the Performance Evaluation of the Lane Departure Warning System)

  • 곽재호;김회율
    • 한국자동차공학회논문집
    • /
    • 제24권6호
    • /
    • pp.627-634
    • /
    • 2016
  • In this paper, an augmented video generation method to evaluate the performance of lane departure warning system is proposed. In our system, the input is a video which have road scene with general clean lane, and the content of output video is the same but the lane is synthesized with contamination image. In order to synthesize the contamination lane image, two approaches were used. One is example-based image synthesis, and the other is background-based image synthesis. Example-based image synthesis is generated in the assumption of the situation that contamination is applied to the lane, and background-based image synthesis is for the situation that the lane is erased due to aging. In this paper, a new contamination pattern generation method using Gaussian function is also proposed in order to produce contamination with various shape and size. The contamination lane video can be generated by shifting synthesized image as lane movement amount obtained empirically. Our experiment showed that the similarity between the generated contamination lane image and real lane image is over 90 %. Futhermore, we can verify the reliability of the video generated from the proposed method through the analysis of the change of lane recognition rate. In other words, the recognition rate based on the video generated from the proposed method is very similar to that of the real contamination lane video.

수질오염 감시체계 구축을 위한 수질 데이터의 통계적 예측 가능성 검토 (A Study on the Statistical Predictability of Drinking Water Qualities for Contamination Warning System)

  • 박노석;이영주;채선하;윤석민
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.469-479
    • /
    • 2015
  • This study have been conducted to analyze the feasibility of establishing Contamination Warning System(CWS) that is capable of monitoring early natural or intentional water quality accidents, and providing active and quick responses for domestic C_water supply system. In order to evaluate the water quality data set, pH, turbidity and free residual chlorine concentration data were collected and each statistical value(mean, variation, range) was calculated, then the seasonal variability of those were analyzed using the independent t-test. From the results of analyzing the distribution of outliers in the measurement data using a high-pass filter, it could be confirmed that a lot of lower outliers appeared due to data missing. In addition, linear filter model based on autoregressive model(AR(1) and AR(2)) was applied for the state estimation of each water quality data set. From the results of analyzing the variability of the autocorrelation coefficient structure according to the change of window size(6hours~48hours), at least the window size longer than 12hours should be necessary for estimating the state of water quality data satisfactorily.

수돗물에서 무기 오염물질 최소 반응 농도 결정의 실험적 고찰 (An Experimental Study on the Determination of Minimum Response Concentration of Inorganic Pollutants in Tap Water)

  • 윤석민;김성수;채선하;박노석
    • 대한환경공학회지
    • /
    • 제39권4호
    • /
    • pp.208-213
    • /
    • 2017
  • 본 연구에서는 국내 실정에 맞는 한국형 CWS 구축의 일환으로 국내 배 급수 시스템에서 오염 사고 발생가능성이 있는 무기 오염물질 네 종류(카드뮴, 크롬, 망간, 납)를 선정하고 batch 실험을 통해 각 오염물질의 수돗물에 주입 시 감지 가능한 "최소 반응 농도(minimum response concentration)"를 결정하고자 하였다. 무기 오염물질 네 종류에 대해 수질 인자들의 최소 반응 농도를 추적한 결과 카드뮴(수질기준 0.005 mg/L)에 대한 최소 반응 농도는 0.05~0.08 mg/L, 크롬(수질기준 0.05 mg/L)에 대한 최소 반응 농도는 0.03 mg/L, 망간(수질기준 0.05 mg/L)에 대한 최소 반응 농도는 0.005 mg/L, 그리고 납(수질기준 0.01 mg/L)에 대한 최소 반응 농도는 0.02~0.08 mg/L인 것으로 분석되었다.

오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구 (Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures)

  • 박선환;장윤영;정정호;손정호;박석효
    • 환경영향평가
    • /
    • 제16권2호
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.

Simulation of Contaminant Draining Strategy with User Participation in Water Distribution Networks

  • Marlim, Malvin S.;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.146-146
    • /
    • 2021
  • A contamination event occurring in water distribution networks (WDNs) needs to be handled with the appropriate mitigation strategy to protect public health safety and ensure water supply service continuation. Typically the mitigation phase consists of contaminant sensing, public warning, network inspection, and recovery. After the contaminant source has been detected and treated, contaminants still exist in the network, and the contaminated water should be flushed out. The recovery period is critical to remove any lingering contaminant in a rapid and non-detrimental manner. The contaminant flushing can be done in several ways. Conventionally, the opening of hydrants is applied to drain the contaminant out of the system. Relying on advanced information and communication technology (ICT) on WDN management, warning and information can be distributed fast through electronic media. Water utilities can inform their customers to participate in the contaminant flushing by opening and closing their house faucets to drain the contaminated water. The household draining strategy consists of determining sectors and timeslots of the WDN users based on hydraulic simulation. The number of sectors should be controlled to maintain sufficient pressure for faucet draining. The draining timeslot is determined through hydraulic simulation to identify the draining time required for each sector. The effectiveness of the strategy is evaluated using three measurements, such as Wasted Water (WW), Flushing Duration (FD), and Pipe Erosion (PE). The optimal draining strategy (i.e., group and timeslot allocation) in the WDN can be determined by minimizing the measures.

  • PDF

Determination of Cadmium and Zinc Contamination Source in Arable Soil in the Vicinity of a Zinc Smelting Factory

  • Hong, Chang-Oh;Gutierrez, Jessie;Lee, Seul-Bi;Lee, Yong-Bok;Yu, Chan;Kim, Pil-Joo
    • 한국환경농학회지
    • /
    • 제26권3호
    • /
    • pp.204-209
    • /
    • 2007
  • Agricultural area in the vicinity of the ${\triangle}{\triangle}$ smelting factory in Kyeongbuk province, the third largest zinc smelting factory in the world, was contaminated by high concentration of heavy metals. However, the heavy metals source was not yet directly traced and thus, resulted to a conflict between the factory and residents within its vicinity. In order to determine the level of heavy metal contamination in the arable lands located at the north eastern part of the factory, soils were sampled systematically. To find out the major reason for the occurrence of this problem, waters and aerosols were sampled with constant intervals to the upward and downward direction from the factory and were analyzed to find out the heavy metal concentrations. Cadmium (Cd) and zinc (Zn) of the heavy metals were highly accumulated more than the Korean warning criteria (Cd 1.5, Zn 300 mg $kg^{-1}$) with mean values 1.7 and 407 mg $kg^{-1}$, respectively, at the surface soils (0-20 cm), and heavy metal concentration significantly decreased with increasing soil depth In addition, the concentration of both metals slightly decreased with increasing distance from the factory to the surface soils. Cadmium and Zn were detected in the upward stream water with low concentration and concentrations increased significantly in the downstream after passing across the factory. Aerosol samples also showed traces of Cd and Zn which could be attributed to the contamination of the water system and the surface soils. Conclusively, Cd and Zn emitted from the ${\triangle}{\triangle}$ smelting factory moved with the aerosol in the atmosphere and thus, contaminated the agricultural areas and the water system within it vicinity.

새만금 전작.원예단지 후보지구 토양의 화학적 특성 (Chemical Properties of Soil in the Proposed Horticultural Complexes of Saemangeum Reclaimed Tideland)

  • 손재권;최진규;조재영
    • 한국농공학회논문집
    • /
    • 제51권4호
    • /
    • pp.67-73
    • /
    • 2009
  • Chemical properties of soil in the proposed horticultural complexes of Saemangeun reclaimed tideland were studied for sustainable development of the newly reclaimed land resources. The soil texture of Gwanghwal, Gyehwa, Mangyeong and Okgu complex area were sandy loam. The pH and ESP (exchangeable sodium percentage) were 7.42 to 7.82 and 61.05 to 73.62 %, respectively. Compared to general agricultural land in Korea, the soil organic matter and other plant nutrients were low. The concentrations of heavy metals in the soil were found to be acceptable except several sites where they doesn't meet the warning standard of agricultural land contamination. Continuous monitoring and interception of external pollutants are suggested for water-soil-plant system conservation.

실시간 마모량 측정을 통한 대형 기계윤활시스템의 파손발생 진단사례 (A case study on the failure diagnosis of plant machinery system by implementing on-line wear monitoring)

  • 윤의성;장래혁;공호성;한흥구;권오관;송재수;김재덕;엄형섭
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.321-327
    • /
    • 1998
  • This paper presented a case study on the application of on-line wear monitoring technique to a high duty air-turbo-compressor system. Main objects monitored were a gear unit and metal bearings, both shown frequent troubles due to the severe operation conditions at heavy dynamic load. The air-turbo-compressor system needs secure condition monitoring because it is one of the main utilities in steel making industry. Temperature and vibration characteristics have been mainly on-line monitored in this system for a predictive maintenance; however, it has been shown that they are not fairly good enough to give an early warning prior to the machine failure. In this work, an on-line Opto Magnetic Detector(OMD) was implemented for an on-line wear monitoring, which quantitatively measured the contamination level of both ferrous and non-ferrous wear particles by detecting the change in optical density of used oil. Results showed that the application of on-line OMD system was satisfactory in diagnosis of the machine system.

  • PDF

측색기를 활용한 건설안전표지의 측색과 평가 (Measurement and Evaluation of the Construction Safety Sign Panel Using Colorimeter)

  • 정철우;이재용
    • 한국건축시공학회지
    • /
    • 제19권3호
    • /
    • pp.273-279
    • /
    • 2019
  • 본 연구에서는 건설현장에 설치된 표지판을 측색하여 색기준에 대한 적합성 검토와 현장여건에 적합한 관리 방안을 제시하고자 하였으며, 현장에 설치된 안전표지판은 관련기준에 적합한 정도가 적색 33%, 황색 22%, 청색 3%, 녹색 28%로 나타나 각각의 현장에 설치된 법적인 기준에 대부분 적합하지 않은 것으로 나타났으며, 청색 안전표지판에 대하여 보다 적극적인 제조생산과 관리에 대한 관련기관의 감독이 필요하다.