• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.025 seconds

A Study on Yeast and Mold Contamination of Fermented Milk Products in Korea (우리나라 유산균 제품의 Yeast, Mold 오염에 관한 조사연구)

  • 홍종해
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.51-57
    • /
    • 1981
  • This Study was carried out to investigate yeast and mold contamination in fermented milk products produced by 9 different domestic manufacturers from October 20. to December 5. 1980 The results obtained in the study were as follows 1) pH values of the products were ranged from pH 3.14 to pH 4.20 and average of sour milk drinks was pH $3.66\pm 0.19$ and fermented milks pH $3.74\pm 0.11$. Therefore the difference of pH average among sour milk drinks and fermented milks was statistically significant. (p<0.01) 2) In case of yeast contamination, yeast was found on all the four producted at the same date. From this result, it seemed that yeast contamination occured during the manufacturing progress. 3) Degree of contamination by the indicator organisms was E. coli positive, 3.7%: over 1,000 yeasts/ml, 14.8% over 10 molds/ml, 0.9%. 4) In the range of over 1,000 yeasts/ml, degree of contamination by yeast was 8.4% in fermented milk and 16.7% in sour milk drink. 5) Yeasts in product C increased to the spoilage number within 5 days and in H increased within 10 days at 5C. At 15$\circ$C, yeast increased to the spoilage number within 15 days in product A.D. 6) It seems that the yeast number of initial contamination should be important than the increase rate as criteria on the fermented Milk products.

  • PDF

The Dyeing Properties and Antibiosis of Fabrics Dyed with Agastache rugosa Extract (배초향 추출액을 이용한 염색포의 염색성 및 항균성)

  • Park, Young-Hee
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.16-25
    • /
    • 2012
  • As the test results for surface color, dyeing durability, antibiosis of cotton fabrics and silk fabrics dyed with Agastache rugosa extract, the following conclusions were obtained. The surface color of all the dyed fabrics was confirmed mostly as a GY system. As the result of chrominance(${\Delta}E_{ab}$) measurement, in the case of cotton fabrics the dyed fabrics treated with $Al_2(SO_4)_3$ mordant showed the highest value and in the case of silk fabrics the non-mordant dyed fabrics showed the highest value. The dyeing durability of test fabrics dyed with Agastache rugosa extract are as follows. As the test results of colorfastness to laundry for cotton dyed fabrics, the discoloration degree showed 1st-2nd grade and the contamination degree showed 4th-5th grade. As the test result of colorfastness to dry cleaning for silk dyed fabrics, the contamination degree showed from 1st to 3rd-4th grade. As the test results of colorfastness to acid artificial perspiration, the discoloration degree showed from 1st to 3rd-4th grade and the contamination degree showed from 3rd to 4th-5th grade. As the test results of colorfastness to alkaline artificial perspiration, the discoloration degree showed from 1st to 4th grade and the contamination degree showed from 3rd to 4th-5th grade. The colorfastness to sunlight showed from 1st to 2nd grade. The colorfastness to rubbing showed from 3rd to 4th-5th grade in dry process and from 2nd-3rd to 4th-5th grade in wet process. As the test results of antibiosis, the decrease rate of germs to virus Klebsiella pneumoniae and Staphylococcus aureus showed at least more than 99% after the wash of 10 times. As the test results of antifungal activity to mycete Trichophyton mentagrophytes and Aspergillus niger, the both cotton and silk dyed fabrics didn't gain the significant antifungal effect.

Spatial assessment of soil contamination by heavy metals from informal electronic waste recycling in Agbogbloshie, Ghana

  • Kyere, Vincent Nartey;Greve, Klaus;Atiemo, Sampson M.
    • Environmental Analysis Health and Toxicology
    • /
    • v.31
    • /
    • pp.6.1-6.10
    • /
    • 2016
  • Objectives This study examined the spatial distribution and the extent of soil contamination by heavy metals resulting from primitive, unconventional informal electronic waste recycling in the Agbogbloshie e-waste processing site (AEPS) in Ghana. Methods A total of 132 samples were collected at 100 m intervals, with a handheld global position system used in taking the location data of the soil sample points. Observing all procedural and quality assurance measures, the samples were analyzed for barium (Ba), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), mercury (Hg), nickel (Ni), lead (Pb), and zinc (Zn), using X-ray fluorescence. Using environmental risk indices of contamination factor and degree of contamination ($C_{deg}$), we analyzed the individual contribution of each heavy metal contamination and the overall $C_{deg}$. We further used geostatistical techniques of spatial autocorrelation and variability to examine spatial distribution and extent of heavy metal contamination. Results Results from soil analysis showed that heavy metal concentrations were significantly higher than the Canadian Environmental Protection Agency and Dutch environmental standards. In an increasing order, Pb>Cd>Hg>Cu>Zn>Cr>Co>Ba>Ni contributed significantly to the overall $C_{deg}$. Contamination was highest in the main working areas of burning and dismantling sites, indicating the influence of recycling activities. Geostatistical analysis also revealed that heavy metal contamination spreads beyond the main working areas to residential, recreational, farming, and commercial areas. Conclusions Our results show that the studied heavy metals are ubiquitous within AEPS and the significantly high concentration of these metals reflect the contamination factor and $C_{deg}$, indicating soil contamination in AEPS with the nine heavy metals studied.

A Study on the Sacrificial Anode for Imparting High Capabilities to Cathodic Protection (전기방식시 적용되는 희생양극의 성능개발에 대한 연구)

  • 김성종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.37-42
    • /
    • 1998
  • Al alloy anode is mostly used for protecting marine structures such as pier steel piles and ship's body. Recently it has been reported that the life of Al alloy anode has been shortened significantly than the original design life. It is suggested that the suspected reasons for this problem mentioned above seems to be the improper protection design of alloy of anode on sea water regardless of environmental facotrs such as flow rate, temperature, contamination degree etc. However there is few paper about to the sea water contamination degree affecting to the life of Al alloy anode. In this study, the property of Al alloy anode was investigated as a parameter of sea water contamination degree such as variation of pH 2, 4, 6, 8, 10 and each sea port's contaminated waters.

  • PDF

Microbial Contamination of Masks Worn by Healthcare Professionals (일부 의료기관 종사자가 사용한 마스크의 미생물 오염 사례)

  • Hyekyung Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.395-402
    • /
    • 2023
  • Objectives: Microbial contamination of face masks used by healthcare professionals can vary depending on the degree of exposure to bioaerosols in various healthcare environments. However, research on this topic is limited. Therefore, we analyzed microbial contamination of N95 respirators used in hospital offices, wards, and outpatient settings. Methods: Samples isolated from N95 respirators worn for 2, 4, and 6 hours were incubated at a temperature of 35-37℃ or 25-28℃ for 24 hours or for 3-7 days, and colony-forming units were counted in chocolate agar, tryptic soy agar, and Sabouraud dextrose agar plates. Total indoor airborne bacteria were also measured in the healthcare environments. Finally, microbial species were identified using Gram staining with a microscopic speculum. Results: The three types of environments did not deviate from the maintenance of standard indoor air quality. There was no difference between the microbial species identified in the healthcare environment and mask contamination. However, the number of bacteria in the masks worn in each environment differed, and the degree of contamination increased with mask-wearing time (p<0.05). Conclusions: Therefore, care must be taken to avoid recontamination of masks due to improper use and exposure to biological hazards in healthcare environments. In conclusion, scientific evidence is necessary for safe mask-wearing times. Based on the results of this study, we hope to conduct further research to establish guidelines for the safe use of face masks during respiratory disease epidemics.

Analysis of the Correlation on the Weather Conditions and the Contamination Degree Using Mu lisle Regression Method (다중회귀를 이용한 기후와 오손도 간의 상관관계 분석)

  • 심규일;최남호;김종석;한상옥
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.199-202
    • /
    • 2001
  • This paper presents the correlation on the contamination degree and weather conditions using the multiple regression of the statistic method. The cotamination is a significant factor in the insulation system. The major factor is natural contamination, and the most is the salt. The salt contamination is occured by the weather conditions. The weather contaminations are wind, precipitation, temperature, relative humidity, etc. The effects of those are different, and the correlation is showed numerically by using the multiple regression method of the statistic method. With this, the estimation of the equivalent salt deposit density(ESDD) becomes possible by the changes of the weather conditions.

  • PDF

Application of Hot Spot Analysis for Interpreting Soil Heavy-Metal Concentration Data in Abandoned Mines (폐금속 광산의 토양 중금속 오염 조사 자료 해석을 위한 핫스팟 분석의 적용)

  • LEE, Chae-Young;KIM, Sung-Min;CHOI, Yo-Soon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.24-35
    • /
    • 2019
  • In this study, a hotspot analysis was conducted to suggest a new method for interpreting soil heavy-metal contamination data of abandoned metal mines according to statistical significance level. The spatial autocorrelation of the data was analyzed using the Getis-Ord $Gi{\ast}$ statistic in order to check whether soil heavy metal contamination data showing abnormal values appeared concentrated or dispersed in a specific space. As a result, the statistically significant data showing abnormal values in the mine area could be classified as follows: (1) the contamination degree and the hotspot value (z-score) were both high, (2) the contamination degree was high but the z-score was low, (3) the contamination degree was low but the z-score was high and (4) the contamination degree and the z-score were both low. The proposed method can be used to interpret the soil heavy metal contamination data according to the statistical significance level and to support a rational decision for soil contamination management in abandoned mines.

The Effect of Glove Changing during Surgery for Colon Cancer (대장암수술 시 장갑교환의 효과)

  • Park, Eunji;Ham, Eunmi
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.1
    • /
    • pp.98-106
    • /
    • 2014
  • Purpose: The purpose of this study was to explore the effect of glove changing during surgery for colon cancer on reducing the degree of contamination of surgical gloves. Methods: The randomized posttest control group design was used. Total 72 surgeries of colon cancer in the K University Hospital in Seoul performed by the team of A-Surgeon and B-Scrub nurse were randomly assigned to one of the three groups. Glove changing with single-gloved state was implemented in the Experimental Group I and outer glove changing with double-gloved state was executed in the Experimental Group II. Single-gloved state was carried in the Control Group. Following the surgical procedure, specimens for bacterial culture were collected the from scrub nurse's gloves to compare the degree of contamination among the three groups. Data were analyzed with One-way ANOVA and the Scheff$\acute{e}$'s multiple comparison test. Results: The degrees of contamination of the Experimental Group I and II were significantly lower than that of the Control Group. There was no significant difference between Experimental Group I and II. Conclusion: Glove changing during surgery with either single or double-gloved state is effective in reducing the degree of contamination of surgical gloves, therefore these methods should be utilized in clinical practice.

A View of Soil Microbial Contamination on the Three Sandy Beaches in Busan (부산광역시 세 해수욕장 백사장에서 세균 오염도 조사)

  • Huh, Man-Kyu;Cho, Kyung-Soon
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.3
    • /
    • pp.202-207
    • /
    • 2011
  • Bacterial contamination of beach sand was examined in April, June, July, and August. Twenty four topsoil and subsoil samples were taken from the 1m and 5m points from the coastline in three Busan beaches (Haeundae, Gwanganli, and Songjeong). The 5m points from the coastline showed higher coliform contamination than 1 m points. July showed the highest bacterial contamination on beaches among surveyed months. Coliform contamination in the subsoil was higher than that of the topsoil. The bacterial contamination of 5m points of topsoil and subsoil in June except the Songjeong Beach was higher than those of July and August. We investigated Staphylococcus aureus, Vibrio parahaemolyticus, Vibrio vulnificus, Vibrio cholerae, and Bacillus cereus. Only B. cereus was detected at the beach in August. Although microbiological pollution of the Gwanganli Beach was the highest among three Busan beaches, the degree of contamination was not high compared to those of other countries. However, sandy soil management in public beach for pathogenic microorganisms is needed.

An Estimation of Contamination Degree using the Statistical Analysis between Contamination and Climatic Data (오손도와 기상 데이터의 통계적 분석을 이용한 오손도 예측)

  • 심규일;김호수;김주한;박흥석;한상옥
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • The accumulation of salt contamination could be the source of electrical accident. The degree of contamination on outdoor insulator is represented by ESDD(equivalent salt deposit density). The salt is transported by the wind to the outdoor insulator and cleaned by the rain. So, we can estimate the relation between climatic data and ESDD by using the multiple regression method. The results of pre-study presented the high relation coefficient(0.874). But these results couldn't apply to another period So, this paper improves above problem by mathematical process of climatic data The main method is accumulation of passed climatic data and conversion of the rainfall by the wind. Then, we confirmed the increasement of relation coefficient(0.898).