• 제목/요약/키워드: contaminated water

검색결과 1,320건 처리시간 0.026초

하상오염물 제거에 의한 수질개선효과 수치모델링 (Numerical Simulation of Water Quality Enhancement by Removal of Contaminated Bed Material)

  • 이남주
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.349-357
    • /
    • 2011
  • This study has an objective to estimate effect on water-quality enhancement by removal of contaminated river-bed material using a two-dimensional numerical modeling in the Seonakdong River, the Pyunggang River and the Maekdo River. RMA2 and RMA4 models were used for flow and contaminant transport simulation, respectively. After the analysis of the effects of flow restoration plan for the Seonakdong River system made by Lee et al (2008), simulation have been performed about scenarios which contains operations of the Daejeo Gate, the Noksan Gate, the Makdo Gate (on planning), and the Noksan Pumping Station. Because there is no option for elution from bed sediment in the RMA4 model, a simple technique has been used for initial condition modification for elution. The analyses revealed that the effect on water quality improvement due to dredging of bed sediment seemed to be less than 10 % of the total effect. The most efficient measure for the water quality improvement of the river system was the linked operation of water-gates and pumping station.

원자력발전과 후쿠시마 오염수에 대한 인식 연구 (A Study on Awareness of Nuclear Power Generation and Fukushima Contaminated Water)

  • 강연희;양성희;조용인;김정훈
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.109-117
    • /
    • 2024
  • 대상으로 온라인 설문을 실시하고, 총 201부의 설문을 분석하였다. 연구대상자의 특성에 따른 변수의 차이 검증을 위해 독립표본t-검정 및 일원배치분산분석을 실시하였으며, 변수 간 연관성 확인을 위해 상관관계분석을 실시하였다. 연구 결과 첫째, 여성이 남성보다 원자력발전과 후쿠시마 오염수에 대하여 더 부정적인 인식을 가지고 있는 것으로 나타났다. 연령에서는 40대 이상에서 부정적 인식이 높은 것으로 조사되었다. 정치 성향에서는 진보성향의 응답자가 원자력발전과 후쿠시마 오염수에 대해 부정적 인식이 더 높은 것으로 나타났다. 둘째, 원자력에 대한 정보 수집은 인터넷과 방송, SNS을 통하여 가장 많이 하는 것으로 나타났다. 셋째, 원자력발전에 대한 부정적인 인식이 높을수록 후쿠시마 원전 오염수 방류 이후 우려되는 문제에 부정적인 결과를 나타냈다. 원자력발전은 인간의 생활권에서 분리할 수 없다. 따라서 원자력발전에 대한 바른 인식을 가질 수 있도록 정확한 정보와 지식 전달 체계가 필요한 것으로 사료된다.

지혈제 오염이 콤포머의 전단결합강도에 미치는 영향 (THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER)

  • 허정무;곽주석;이황;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

계면활성제를 이용한 포화지층내 저비중 비수용성 유기용매의 제거거동에 관한 연구 (An Experimental Study on Surfactant Enhanced LNAPL Removal Behavior in Saturated Zone)

  • 이재원;박규홍;박준범;임경희
    • 한국지반공학회논문집
    • /
    • 제15권5호
    • /
    • pp.291-300
    • /
    • 1999
  • BTEX로 오염된 혼합토(사질토/점토)의 정화를 위한 계면활성제 기법의 적용성 및 제거효율에 대한 연구를 진행하였다. 초기농도 275mg/kg으로부터 1975mg/kg의 BTEX로 오염시킨 8개의 컬럼에 물, methyl alcohol과 계면활성제 용액을 주입하였고 이때 계면활성제와 첨가물의 혼합과 비혼합시에 대해 제거거동을 비교 분석하였다. 물을 이용한 흙 세척법의 적용 결과 850 간극부피의 물을 주입하여 98%의 제거 효율을 보였으나 8mg/kg 이하의 저농도에서는 더 이상 제거가 이루어지지 않고 일정한 양상을 가지는 tailing effect를 보였다. 본 실험 결과 가장 우수한 조건은3% ethyl alcohol과 3% SXS를 첨가한 4% SOFTANOL(equation omitted)-90을 간헐적으로 주입한 경우였으며 이 때 95 간극부피에서 99.5%의 제거효율을 보였다. 실험결과 물을 주입하였을 경우 850 간극부피를 주입한 반면, 계면활성제 적용시 95-165 간극부피에서 84.5%-99.5%의 제거효율을 보였는데 이는 계면활성제 기법을 오염된 지반 정화에 효율적으로 적용할 수 있음을 나타내는 것이다.

  • PDF

Phytoremediation of Disel-Contaminated Soil by Poplar Tree

  • 조수형;장순웅
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.252-254
    • /
    • 2004
  • In the past several years phytoremediation, defined as the use of plants for removing contaminants from media such as soils or water, has attracted a great deal of interest as a potentially useful remediation technology. In this study, we have attempted to asses the effectiveness of phytoremeidation of disel contaminate soils using hybrid poplar species. 3 poplar species had removed disel from soil effectively and toxic effect was also observed over 2500mg/kg disel contaminated soil, which indicating reducing disel removal.

  • PDF

유류오염부지의 복원설계 (Remedial Design of a Site contaminated with petroleum)

  • 윤성욱;조병진;유찬
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.417-422
    • /
    • 2005
  • The procedure of investigation and design of the soil contaminated with petroleum was introduced. Soil and water quality analyses were carried out to figure out the type of contaminants and the flume range according to the national regulation. In the investigation, it was verified that the soils in several dispersed locations were contaminated with petroleum. Therefore, in the design process, it was necessary to select a optimal remediation method after making the conception model of the site, and then the treatment method of incineration was selected.

  • PDF

공극수 오염이 시멘트 고화처리된 사질토에 미치는 영향 (The Influence of Pore Water Contamination on the Cement Treated Sandy Soil)

  • 유찬
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.144-152
    • /
    • 2003
  • Laboratory experiments were carried out to investigate the influence of pore water contamination on the treatment effect of sandy soil which was solidified by Portland cement. In the experiments, setting time of hydraulic cement that was mixed with contaminated mixing water was measured using Vicat equipment and observed the tendency of setting process with the kind of contaminants, organic or inorganic components. It was shown that organic contaminants of the mixing water affect largely on the initial setting process of hydraulic cement and inorganics, expecially heavy metals, did not affect on the initial setting process, otherwise it was appeared that setting time of the sandy soil that was contaminated with inorganic components was apparently faster than the sandy soil that did not include inorganic components even though organic concentrations was relatively low level (COD=200∼300) in the mixing water. The results of unconfined compression strength test (UCST) were well consistent with the results of Vicat equipment test.

A Study of surfactant-based remediation for removal of toluene and PCE in contaminated water

  • Kim, Eun-Sik;Lee, Dal-Heui;Chang, Ho-Wan
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.302-305
    • /
    • 2003
  • The purpose of this study was to assess the effect of surfactant on the rate of NAPLs(non-aqueous phase liquids) solubilization. The experimental variables were surfactant type, NAPLs type and water type. The main experimental designs were consists of two phases. The solubilization rate is sensitive to surfactant type based on this test. Used aqueous surfactants were solubilized and removed 72.77 to 89.90% of toluene, PCE(tetrachloroethylene) from the contaminated water during the test, respectively. T60 has higher and stable recovery ratio than SDS in surfactant type but, the micelle of the T60 is more weaker than that of SDS based on this study's results. And the solubilization rate in used water type was almost same.(deionized water, surface water).

  • PDF

汚濁河川水의 地球化學的인 硏究 (第 II 報) 서울市內 河川水 및 工場排水의 化學的 酸素要求量 (Geochemical Investigations of Contaminated River Waters Part II-Chemical Oxygen Demand of River Water and Industrial Waste Water in Seoul)

  • 이용근
    • 대한화학회지
    • /
    • 제14권1호
    • /
    • pp.5-12
    • /
    • 1970
  • River water and industrial waste water in Seoul were studied by means of chemical oxygen demand(COD) as an indicator for water pollution, from August 1967 to July 1968. Rivers flowing through residential and industrial areas are badly contaminated and COD of water in Han River increases as it progresses to downstream. Seasonal variation of COD showed that higher value of COD was observed in spring and lower in autumn. It is clear that the seasonal variation of COD is influenced by the precipitation. Close relationship was found between COD and population density. The lowest COD curve obtained by plotting COD values against population density and show that the curve slopes upward. The discontinuation of the curve was shown at the population density of 14,000/km$^2$; an increase in COD was acute over the population density of 14,000/km$^2$.

  • PDF

첨상면 오염이 레진 의치상의 파절강도에 미치는 영향 (EFFECT OF SURFACE CONTAMINATION ON THE TRANSVERSE STRENGTH OF THE RELINED DENTURE)

  • 김정현;배정수;한동후
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.11-18
    • /
    • 1993
  • Autopolymerising and visible light cured resin are used to reline dentures. But relined surface are easily contaminated by water or saliva in the mouth during clinical procedure. This study was to find out the effect of surface contamination on the transverse strength of the relined denture base. To accomplish this, the specimens of $65\times10\times3mm$ were made with heat-cured(Lucitone 199), visible light-cured(Triad), and autopolymerizing resin(Kooliner). Measurements of transverse strength were taken for each specimen. Specimens made of heat-cured resins, sizing $65\times10\times1.5mm$, were relined with heat-cured, light-cured, and autopolymerizing resin, respectively. Specimens relined with autopolymerizing and light-cured resins were further classified into not-contaminated, water-contaminated and saliva-contaminated groups. Again, measurements of the transverse strength were taken for each group. The results were as follows 1. The transverse strength of heat-cured resin was superior to all the other resins. 2. The transverse strength of each specimen decreased after relining in the following order, heat-cured, visible light-cured, and autopolymerizing resin. 3. Surface contamination produced an decrease in transverse strength, especially in the saliva contaminated group. According to these results, water or saliva contamination should be avoided during intraoral relining procedures.

  • PDF