• Title/Summary/Keyword: contaminated part

Search Result 186, Processing Time 0.027 seconds

A Study on Optimal Operation for Soot Blower of Power Plant (발전용 Soot Blower 최적운전에 관한 연구)

  • Kim, Sung-Ho;Jung, Hae-Won;Yook, Sim-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.541-543
    • /
    • 2004
  • An optimal soot blowing system has been developed for an optimal operation of power utility boilers by both minimization of the use of steam and the number of soot blowers worked during soot blowing. Traditionally, the soot blowing system has been operated manually by operators. However, it causes the reduction of power and thermal performance degradation because all soot blowers installed in the plant should be worked simultaneously even there are lots of tubes those are not contaminated by slagging or fouling. Heat transfer area is divided into four groups, furnace, convection area including superheater, reheater and economizer, and air preheater in the present study. The condition of cleanness of the tubes is calculated by several parameters obtained by sensors. Then, a part of soot blowers works automatically where boiler tubes are contaminated. This system has been applied in a practical power plant. Therefore, comparison has been done between this system and manual operation and the results are discussed.

  • PDF

A Study on the Purification of Water-Pool in Irradiated Materials Examination Facility

  • Song, Ung-Sup;Lee, Jong-Heon;Lee, Hong-Gyee;Hong, Kyon-Pyo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.42-50
    • /
    • 2004
  • The pool $(3m{\times}6m{\times}10m{\times}$ in Irradiated Materials Examination Facility is generally used to transport irradiated materials between a moving cask and hot-cell. During the operation in the pool such as loading/unloading the cask, holding specimen and bucket elevation, water maybe contaminated by radioactive or contaminated impurities from irradiated materials. Then, it must be purified and filtered continuously to keep lower radioactivity than that of regulation prescribed by RCA Korea Activity in a part of radioactive contamination control. This paper described radioactive contamination distribution of water as transported materials, which is related to effective operation of purification and filtration system.

  • PDF

Geochemical Investigations of Contaminated River Waters Part II-Chemical Oxygen Demand of River Water and Industrial Waste Water in Seoul (汚濁河川水의 地球化學的인 硏究 (第 II 報) 서울市內 河川水 및 工場排水의 化學的 酸素要求量)

  • Lee, Yong-Keun
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.5-12
    • /
    • 1970
  • River water and industrial waste water in Seoul were studied by means of chemical oxygen demand(COD) as an indicator for water pollution, from August 1967 to July 1968. Rivers flowing through residential and industrial areas are badly contaminated and COD of water in Han River increases as it progresses to downstream. Seasonal variation of COD showed that higher value of COD was observed in spring and lower in autumn. It is clear that the seasonal variation of COD is influenced by the precipitation. Close relationship was found between COD and population density. The lowest COD curve obtained by plotting COD values against population density and show that the curve slopes upward. The discontinuation of the curve was shown at the population density of 14,000/km$^2$; an increase in COD was acute over the population density of 14,000/km$^2$.

  • PDF

Geochemical Investigation in Contaminated River Waters(Part III) Bromine Contents of River Water in Seoul (汚濁河川水의 地球化學的인 硏究(第 III 報) 서울市內 河川水의 브롬舍量)

  • Lee, Yong-Keun
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.3
    • /
    • pp.243-256
    • /
    • 1970
  • Halogen contents of the river water of Seoul city and of municipal reservoirs were investigated from June in 1969 to February in 1970. Bromine contents were ranging from 0.006 to 0.048 mg/1 of the reservoirs, 0.021 to 0.048 mg/1 of Han River, 0.051 to 0.540 mg/1 of rivers running through residential areas and 0.083 to 0.920 mg/1 of rivers running through industrial areas. Bromine contents increased as the river water became contaminated. Most of Br/Cl of Han River and the reservoirs were higher than $3.4{\times}10^{-3}$ of sea water. Bromine contents at 17 different places were the largest in November. The contents of chlorine, iodine and COD (chemical oxygen demand) were nearly correlated with that of bromine. Bromine contents of the river waters in Seoul chiefly originated from consumption of domestic and industrial salt.

  • PDF

ICT-based Waste Plastic Management Life Cycle Technology (ICT기반 폐플라스틱 관리 전주기 기술 동향)

  • Moon, Y.B.;Jeong, H.;Heo, T.W.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • To solve the challenge of waste plastics, this study investigated the related technologies and company trends along the plastic life cycle, and primarily describes ICT technologies to improve efficiency in the process of sorting and sorting waste plastics. Waste plastic discharge caused by the explosive increase in parcel traffic because of COVID-19 is also growing exponentially. Hence, waste treatment is emerging as a social challenge. Most of the domestic waste classification depends on the manual process according to the waste pollution level. The plastic material classification approach using the spectroscopy approach reveals a high error in the contaminated waste plastic classification, but if the Artificial Intelligence-based image classification technology is employed together, the classification precision can be enhanced because of the type of waste plastic product and the contaminated part can be differentiated.

Fiber-optic biosensor for the detection of organophosphorus compounds in a contaminated water (Part II : The signal analysis and simulation) (오염수 내의 유기인 화합물의 측정을 위한 광섬유 바이오센서 (제 2 부 : 신호분석 및 수치모사))

  • Choi, Jeong-Woo;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.16-23
    • /
    • 1994
  • Developed fiber-optic biosensor for the detection of organophosphorus compounds in a contaminated water needs the analysis of an enzyme kinetics and the transport phenomena in the reaction part to analyze the sensor signal and to design the sensor. The enzyme inhibition kinetics was investigated and the reactor model was proposed to design the reaction part in the proposed sensor. Since the acetylcholinesterase was inhibited by the organophosphorus compounds, experiments for enzyme inhibition reaction were performed from 0 to 2 ppm to be detected by the developed sensor, and irreversible enzyme inhibition kinetics was proposed. The reactor parts were divided into the two phases, i.e. bulk phase and immobilized enzyme layer, to analyze the flow and diffusion. Sensor signal was able to be analyzed based on the total reactor model established by linking the enzyme reaction kinetics. Based on the proposed model, the effects of loading enzyme amount and enzyme layer thickness on the magnitude of readout signal were simulated.

  • PDF

Biological Monitoring of Arsenic Concentrations According to Exposure to Arsenic-contaminated Ground Water (모 지역 소규모급수시설 비소검출에 따른 생물학적 노출 평가)

  • Seo, Jeong-Wook;Choi, Jae-Won;Oh, Yu-jin;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.513-524
    • /
    • 2020
  • Objective: The main purpose of this study is to evaluate the environmental and biological exposure of local residents who consumed arsenic-contaminated drinking water for less than one year. Methods: As a part of water quality inspections for small-scale water supply facilities, surveys were conducted of residents of two villages that exceeded the arsenic threshold for drinking water. The environmental impact survey consisted of surveys on water quality, soil, and crops in the surveyed area. Biological monitoring was performed by measuring the separation of arsenic species in urine and total arsenic in hair. Results: In the results of biological monitoring, the concentrations of AsIII and AsV were 0.08 and 0.16 ㎍/L, respectively. MMA and DMA were 0.87 and 36.19 ㎍/L. There was no statistically significant difference between the group who drank arsenic-removed groundwater or water from the small-scale supply facility and the group who drank tap water, purified water, or commercial bottled water. Some of the water samples exceeded the arsenic threshold for drinking water. There were no samples in the soil or rice that exceeded the acceptable threshold. Conclusion: In the case of short-term exposure to arsenic-contaminated drinking water for less than one year, there were no significant problems of concern from the evaluation of biological monitoring after arsenic was removed.

Study on the soil contamination characteristics according to the functions of the returned U.S. military base (반환미군기지 기능별 토양오염특성에 관한 연구)

  • Oh, Chang-Gyu
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.5
    • /
    • pp.481-489
    • /
    • 2013
  • There are U.S. troops with a force about 290,000 strong stationed all around the world, approximately 150 countries. Among the troops, USFK has performed principal part with its stationing for 50 years against the military threat of North Korea. However, as a result of an investigation made into environmental contamination of several bases which were restituted from US to ROK by the Land Partnership Plan in the process of relocation of USFK, it was found that the area was contaminated by not only TPH and BTEX caused by diesel fuel and JP-8 but also various heavy metal over the standard level according to the operations of corps. Among these bases, 4 corps, each of which has different duties and function, were chosen to be analyzed for the characteristics and degrees of soil contamination. Fisrt of all, in armored camp the soil was contaminated by TPH and heavy metal (Zn, Ni, Pb) due to the repairing activities of tracked vehicles and shooting exercises. In army aviation camp, the soil was contaminated by TPH, BTEX and heavy metal (Zn, Cd) due to repairing activities of aircrafts. Also, in engineer camp there was contaminated area polluted by TPH and heavy metal (Zn, Pb) caused by open-air storage of various construction materials and TPH, BTEX and heavy metal (Zn, Pb, Cu) contamination of aircraft shooting area in shooting range camp were detected. Managing environment will be more effective when we identify the contaminative characteristics and take necessary measures in advance.

Partially linear multivariate regression in the presence of measurement error

  • Yalaz, Secil;Tez, Mujgan
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.5
    • /
    • pp.511-521
    • /
    • 2020
  • In this paper, a partially linear multivariate model with error in the explanatory variable of the nonparametric part, and an m dimensional response variable is considered. Using the uniform consistency results found for the estimator of the nonparametric part, we derive an estimator of the parametric part. The dependence of the convergence rates on the errors distributions is examined and demonstrated that proposed estimator is asymptotically normal. In main results, both ordinary and super smooth error distributions are considered. Moreover, the derived estimators are applied to the economic behaviors of consumers. Our method handles contaminated data is founded more effectively than the semiparametric method ignores measurement errors.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF