Optimum Design of the Process Parameter in Sheet Metal Forming with Design Sensitivity Analysis using the Direct Differentiation Approach (I) -Design Sensitivity Analysis- (직접미분 설계민감도 해석을 이용한 박판금속성형 공정변수 최적화 (I) -설계민감도 해석 -)

  • Kim, Se-Ho;Huh, Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2245-2252
    • /
    • 2002
  • Design sensitivity analysis scheme is proposed in an elasto -plastic finite element method with explicit time integration using a direct differentiation method. The direct differentiation is concerned with large deformation, the elasto-plastic constitutive relation, shell elements with reduced integration and the contact scheme. The design sensitivities with respect to the process parameter are calculated with the direct analytical differentiation of the governing equation. The sensitivity results obtained from the present theory are compared with that obtained by the finite difference method in a class of sheet metal forming problems such as hemi-spherical stretching and cylindrical cup deep-drawing. The result shows good agreement with the finite difference method and demonstrates that the preposed sensitivity calculation scheme is a pplicable in the complicated sheet metal forming analysis and design.

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

The Effects of Spherical and Aspherical RGP Contact Lenses on Visual Performance (구면 및 비구면 RGP 콘텍트렌즈가 시력의 질에 미치는 영향)

  • Kim, Soo-Hyun;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2009
  • Purpose: This study was to evaluate corneal topography, contrast sensitivity and ocular response of a RGP, back surface aspherical contact lens compared with a spherical contact lens. Methods: A total 37 subjects were fitted with a spherical lens in right eye and an aspherical in the left eye and were evaluated for changes in corneal topography and contrast sensitivity over a 2-month period. Results: Thirty-four of 37 subjects completed the 2-month study. The corneal topography did not show differences between spherical and aspherical RGP lenses. The eyes fitted with the aspherical lenses demonstrated a greater reduction in contrast sensitivity compared with their spherical counterparts under photopic condition. Subjects preferred comfort and ocular responses provided by the spherical lens. Conclusions: Corneal topography when comparing spherical and back surface aspherical RGP lenses did not show any significant difference in the subjects. Spherical RGP lens yields better contrast sensitivity and preference than aspherical RGP lens at photopic condition. Further investigation of aberrations induced by contact lens design is warranted to explain the observed differences in visual performance.

  • PDF

Monitoring of Temperature and Strain Variation with FBG Sensors (FBG 센서를 활용한 온도와 스트레인 변화 모니터링)

  • Ko, Ki-Han;Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Cho, Yong-Suk;Choi, Won-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.218-221
    • /
    • 2009
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains, We used FBG (Fiber Bragg Grating) sensors to measure the strain variation of overhead contact line. FBG sensors can sensitively measure the variation of strain and! or temperature by the shift wavelength of reflected wave according to the lattice variation during the measurement. FBG sensor were attached on the contact line and connected to the monitoring system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX (Korea Train eXpress).

Strain monitoring of overhead contact line with FBG sensors (FBG 센서를 활용한 가공 전차선의 스트레인 모니터링)

  • Choi, Won-Seok;Ko, Ki-Han;Lee, Kyung-Bok;Park, Young;Cho, Yong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1227-1230
    • /
    • 2008
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains. We used fiber Bragg grating (FBG) sensors to measure the strain variation of overhead contact line. FBG sensors were attached on the contact line and connected to the monitering system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX.

  • PDF

Design Sensitivity Analysis for the Sheet Metal Forming Process with an Elasto-plastic Finite Element Analysis and a Direct Differentiation Approach (탄소성 유한요소법과 직접미분법물 이용한 박판성형공정에서의 설계민감도 해석)

  • Kim S. H.;Huh H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.93-96
    • /
    • 2001
  • Design sensitivity is calculated in the sheet metal forming process with an elasto-plastic finite element analysis and a direct differentiation method The sensitivity analysis is concerned with the time integration the constitutive relation considering planar anisotropy, shell elements and the contact scheme. The present result is compared with the result obtained with the finite difference approach in deep drawing processes. The obtained sensitivity information is applied to the simple optimization process for the sheet metal forming process.

  • PDF

Infant-Child Care Teacher Interaction : Infant Development, Teachers' Sensitivity and Early Home Environment (보육시설에서의 영아-교사 상호작용과 영아의 발달수준, 교사의 민감성 및 초기 가정환경 간의 관련성에 관한 연구)

  • Choi, Eun-Jung;Ha, Ji-Young;Seo, So-Jung
    • Korean Journal of Child Studies
    • /
    • v.30 no.2
    • /
    • pp.71-95
    • /
    • 2009
  • This study investigated relationships among infant development, teacher's sensitivity, home literacy environment, and infant-teacher interaction in the child care setting. Verbal and behavioral interactions between 30 2-year-old infant-teacher pairs were video-recorded during free play activities; teachers' sensitivity was observed by trained observers; infant development was assessed by teachers; data on the early home literacy environment were gathered through maternal self-reported questionnaires. Data were analyzed by descriptive statistics, t-tests, and correlation analyses. Results indicated that boys showed more naming; girls showed more physical contact with teachers. Infants high in overall developmental level showed more behavioral interaction with teachers. Teacher's sensitivity correlated positively with behavioral imitating and negatively with questioning and nodding. Verbal interaction in the home correlated positively with nodding.

  • PDF

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

Magneto resistance in NiO/NiFe/Cu/NiFe spin-valve Sandwiches (NiO/NiFe/Cu/NiFe 스핀-밸브 샌드위치의 자기저항 특성)

  • 김재욱
    • Electrical & Electronic Materials
    • /
    • v.10 no.10
    • /
    • pp.1016-1021
    • /
    • 1997
  • Magneto resistance properties in spin-valve sandwiches with various thickness of nanmagnetic layer in contact with the ferromagnetic NiFe film were investigated. The NiFe layer in contact with the NiO film was pinned by strongly exchange-biased coupling and the free NiFe layer at the film surface induced a sharp change in the magnetoresistance at -5~15Oe due to small coercivity. The NiO/NiFe/Cu/NiFe film showed a magnetoresistance ratio in the range of 2.3~2.9% and a field sensitivity above 2.2%/Oe with various of nonmagnetic layer. The NiO/NiFe/Cu/NiFe film of the field sensitivity above 2.2%/Oe suggests stang possibility of magnetic sensor matter.

  • PDF

Lateral Force Calibration of Colloidal Probe in Liquid Environment Using Reference Cantilever (기준 외팔보를 이용한 액체 환경에서 Colloidal Probe의 수평방향 힘 교정)

  • Je, Youngwan;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • There is an indispensable need for force calibration for quantitative nanoscale force measurement using atomic force microscopy. Calibrating the normal force is relatively straightforward, whereas doing so for the lateral force is often complicated because of the difficulty in determining the optical lever sensitivity. In particular, the lateral force calibration of a colloidal probe in a liquid environment often has a larger uncertainty as a result of the effects of the epoxy, the location of the colloidal particle on the cantilever, and a decrease in the quality factor. In this work, the lateral force of a colloidal probe using a reference cantilever with a known spring constant was calibrated in a liquid environment. By obtaining the spring constant and the lateral sensitivity at the equator of a spherical colloidal particle, the damage to the bottom surface of the colloidal particle could be eliminated. Further, it was shown that the effect of the contact stiffness on the determination of the lateral spring constant of the cantilever could be minimized. It was concluded that this method can be effectively used for the lateral force calibration of a colloidal probe in a liquid environment.