• 제목/요약/키워드: contact safety factor

검색결과 96건 처리시간 0.032초

베어링 캡 유한 요소 해석 설계 방법 (Design Methodology of Main Bearing Cap by a Finite Element Analysis)

  • 양철호;한문식
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.80-86
    • /
    • 2009
  • Main bearing cap is one of the essential structural elements in internal combustion engine. Main bearing cap guides and holds the crankshaft, withstanding the full combustion and inertia loads of the engine. A seamless design methodology using FEA has been proposed to produce a reliable design of main bearing cap. A Levy's thick cylinder model was applied to calculate the contact pressure between bearing shell and housing bore. A calculated contact pressure at housing bore is within the allowed limit comparing with that from bearing shell model. An adequate FEA model was suggested to obtain reliable solutions for the durability of main bearing cap. 3D global model consists of engine bulkhead, main bearing cap, and bolts. Sub-model consisting of cap and part of bolts is used to get detailed solution of main bearing cap. A very careful contact modeling practice is needed to resolve the convergence problems frequently encountering during combined geometric and material non-linear problems. A proposed methodology has been applied to the main bearing cap model successfully and obtained reliable stress results and fatigue safety factors.

과실 경도측정을 위한 비접촉 초음파 변환기 연구 (Study on Non-contact Ultrasonic Transducer for Measurement of Fruit Firmness)

  • 이상대;하태훈;김기복;김만수
    • Journal of Biosystems Engineering
    • /
    • 제35권3호
    • /
    • pp.189-196
    • /
    • 2010
  • This study was conducted to develop an non-contact ultrasonic transducer for measurement of fruit firmness. The center frequency of non-contact ultrasonic transducer was 500 kHz. As an active element of non-contact ultrasonic transducer, the 1-3 piezoelectric composite material was selected. That material has high piezoelectric properties such as electro-mechanical coupling factor, $k_t$ and piezoelectric voltage constant, $d_{33}$ and also that material has low acoustical impedance which enables to matching the acoustical impedances between piezoelectric material and air. As a front matching material between 1-3 piezoelectric composite material and air, various kinds of paper with different thickness were tested. To control the dead-zone of the fabricated non-contact ultrasonic transducer, the backing material composed of epoxy resin and tungsten powder were made and evaluated. The fabricated non-contact ultrasonic transducer for fruit showed that the cneter frequency, bandwidth and beamwidth were approximately 480 kHz, 30 % and 12 mm, respectively. It was concluded that non-contact measurement of apple firmness would be possible by using the fabricated non-contact ultrasonic transducer.

석탑구조물의 표면거칠기 및 충전재에 따른 석재접촉면의 구조특성 분석 (Structural Characteristics Analysis of Stone Contact Surface according to Surface Roughness and Filling Material of Stone Pagoda Structure)

  • 김호수;김동관;이승희;김덕문;조상순
    • 대한건축학회논문집:구조계
    • /
    • 제34권6호
    • /
    • pp.19-27
    • /
    • 2018
  • The stone pagoda structure is treated as a discontinuous masonry structure, and the contact surface characteristics between stones is a very important factor in the discontinuum behavior analysis. So, it is necessary to find out material and structural characteristics of stone contact surface to perform the structural analysis for safety evaluation. Accordingly, it is important to analyze the material properties of stone surface and secure the structural characteristics through various contact surface states. Therefore, in this study, various test specimens applying the filler between the surface roughness and the stone in the contact surface treatment technique of the stone pagoda were manufactured, and compression test and shear test were carried out. Also, we analyzed the material and structural characteristics of the stone contact surface through the comparison of experimental results.

실 작업 부하를 이용한 로타베이터 기어박스의 강도 평가와 치면 접촉 패턴 해석 (Gear Rating and Contact Pattern Analysis for Rotavator Gearbox Using Actual Working Load)

  • 김정길;조승제;이동근;오주영;신민석;박영준
    • 한국기계가공학회지
    • /
    • 제20권6호
    • /
    • pp.92-99
    • /
    • 2021
  • The rotavator is attached to the three-point hitch at the rear of a tractor and uses the power take-off strength of the tractor to perform soil harrowing. During operation, the power transmitted to the gearbox of the rotavator varies with the soil characteristics and depth. These properties influence the reliability of the gearbox. In this study, actual load measurements and analyses were performed using a rotavator. In addition, the safety factor and fatigue life of the gearbox components were determined using the analysis results. Through analysis and tests, the contact pattern of the gear tooth surface was identified. The input power values of the gearbox were minimum and maximum at 54.5% and 84.5% of the tractor power, respectively. Based on the actual load analysis results, the strength and fatigue life of the gearbox components were satisfied. In addition, through the analysis and testing of the gear contact pattern, it was confirmed that a similar contact occurred. Through the analysis, the magnitude of the load acting on the tooth surface of the gear was confirmed.

Wet-work Exposure: A Main Risk Factor for Occupational Hand Dermatitis

  • Behroozy, Ali;Keegel, Tessa G.
    • Safety and Health at Work
    • /
    • 제5권4호
    • /
    • pp.175-180
    • /
    • 2014
  • Wet-work can be defined as activities where workers have to immerse their hands in liquids for >2 hours per shift, or wear waterproof (occlusive) gloves for a corresponding amount of time, or wash their hands >20 times per shift. This review considers the recent literature on wet-work exposure, and examines wet-work as a main risk factor for developing irritant contact dermatitis of the hands. The aim of this paper is to provide a detailed description of wet-work exposure among specific occupational groups who extensively deal with water and other liquids in their occupations. Furthermore, it highlights the extent and importance of the subsequent adverse health effects caused by exposure to wet-work.

3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치 (Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater)

  • 이문형;김찬오
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

강수의 영향에 따른 Pantograph 주습판의 마모특성 분석 (Analysis on Wearing Characteristics of Main Wearing Slider for Pantograph According to Precipitation)

  • 김경섭;김관수;조관현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.994-999
    • /
    • 2011
  • The main wearing slider of pantograph is a difference which is considerable to wear phenomenon according to material properties. Especially, Cu-type wearing slider suddenly occurs the abnormal wear by precipitation, this threatens the travelling safety of the train. The abnormal wear by precipitation and arc influences are main factor decided to life time of Cu-type wearing slider and contact wire. Consequently, the application of the main wearing slider with wear resisting capacity, electrical conductivity, resistance arc and lubrication is demanded. In this paper through tribologic approach, overcame abnormal phenomenon of the Cu-type wearing slider by the precipitation and for the economic efficient augmentation by durability improvement and the travelling safety were accomplished. The Cu-type wearing slider which has excellent electric conductivity and arc characteristic but it occurs the normal and abnormal wear phenomenon according the precipitation which changes, respectively. Consequently, this phenomenon grasps fixed quantity according to precipitation, a mileage and wear volume then Fe-type wearing slider compared and analyzed.

  • PDF

유한요소해석을 통한 수평 및 수직볼트로 체결된 PHC 파일 연결부의 안전성 평가 (Safety Evaluation of Horizontal and Vertical Bolted Connection between PHC Piles Using Finite Element Analysis)

  • 김수은;김성보
    • 한국강구조학회 논문집
    • /
    • 제30권2호
    • /
    • pp.97-104
    • /
    • 2018
  • PHC 파일을 연결하기 위해 수평 및 수직 볼트를 사용한 연결부의 안전성 평가를 유한요소해석을 통하여 수행하였다. 수치해석 모델은 유한요소해석 프로그램인 ABAQUS를 이용하였으며 모든 연결 장치를 3D Solid 모델로 모델링하였다. 볼트 연결부는 ABAQUS에 제시된 Contact 및 Tie 조건에 고려하여 검토하였다. 유한요소해석을 통해 PHC 파일 연결부의 압축, 인장, 휨 및 전단 해석을 수행하였으며, 각 연결 장치에서 발생하는 Von-Mises 응력을 도출하여 볼트연결부의 안전성을 평가하였다.

미 군사규격을 적용한 권취 코어 자동공급장치의 진동해석 (Vibration Analysis of Film Winding Core Automatic Supply System Using US Military Standards)

  • 고정일;박수현;허장욱
    • 한국기계가공학회지
    • /
    • 제21권4호
    • /
    • pp.91-99
    • /
    • 2022
  • By applying METHOD 514.8 of the US military standard MIL-STD-810H, vibration analysis of the winding core automatic feeding device was performed during vehicle transportation. The contact point between the LM guide and main support frame was weak in the vertical axis, transverse axis, and longitudinal axis during the transportation of the automatic winding core feeder vehicle, and the maximum equivalent stress was 236.31 MPa in the longitudinal axis. When random vibration was applied, the safety margin in the longitudinal direction was 0.26, indicating low safety. The safety margin was changed by increasing the damage factor to 0.1. Finally, the safety margin was improved to 3.48 to secure safety. Resonance occurred with a Q factor of 9.34 in the harmonic response to which the RMS value of the ASD data was input, and the vertical axis safety margin was derived as 0.16. When the damping factor was 0.15, the Q factor was 3.37, and resonance was avoided with a safety margin of 6.62.

Predicting the Firmness of Apples using a Non-contact Ultrasonic Technique

  • Lee, Sangdae;Park, Jeong-Gil;Jeong, Hyun-Mo;Kim, Ki-Bok;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제38권3호
    • /
    • pp.192-198
    • /
    • 2013
  • Purpose: Methods for non-destructive estimation of product quality have been reported in various industrial fields, but the application of ultrasonic techniques for the agricultural products of potatoes, pears, apples, watermelons, kiwis and tomatoes etc. have been rarely reported since the application of a contact-type ultrasonic transducer in agricultural products is very difficult. Therefore, this study sought to determine the firmness of apples using non-contact ultrasonic techniques. Methods: For this experiment, an ultrasonic experimental tester using a non-contact ultrasonic transducer was created, and a signal processing program was used to analyze the acquired ultrasonic reflected signal. Also, a universal testing machine was used to measure firmness parameters of the apples such as bioyield strength, a firmness factor, after the ultrasonic tests had been performed. Results: Six distance correction factors were calculated to obtain consistent values of ultrasonic properties regardless of the distance between the transducer and the surface of the subject. We developed prediction models of the bioyield strength using the distance correction factors. Conclusions: The optimum prediction model of the bioyield strength of apples using a non-contact ultrasonic technique was a multiple regression model ($R^2=0.9402$).