• Title/Summary/Keyword: contact lenses

Search Result 216, Processing Time 0.021 seconds

Clinical fitting of soft contact lenses

  • Cho-BOptom, Pauline
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.81-91
    • /
    • 2004
  • The use of soft contact lenses for myopia correction is increasing in many countries. It is therefore important for contact lens practitioners to be properly educated in fitting these lenses. Before fitting lenses, it is important to consider the factors and procedures related to soft contact lens fitting, indications and contraindications of fitting soft contact lenses. In this article, the functions and activities involved in preliminary, fitting and delivery consultations will be presented.

  • PDF

The Evaluation of Property of Colored Contact Lenses (칼라콘택트렌즈의 물성적 특성 평가)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.119-126
    • /
    • 2005
  • The purpose of this study was analyzed to compare on the physical characters of two companies of color contact lenses. Artificial tear solution was used for measuring the rate of protein deposits and wettability. The surface roughness of lenses was measured by SEM(scanning electron microscope, Japan) and AFM(atomic force microscope, MultimodeTM, USA). As a results, The color contact lenses was not different from general soft contact lenses in a respect of other properties. However, the colored contact lenses showed a severe crack on the surface under SEM observation. There was no irregularity on the surface of the colored contact lenses in AFM photograph. The dyes were deposited in inside of lenses by microscope observation.

  • PDF

Effect of Crosslinking Agent Structure on Drug Release and Antibacterial Effect of Contact Lenses (교차결합제 구조가 콘택트렌즈의 약물용출 및 항균효과에 미치는 영향)

  • Lee, Pil-Heon;Lee, Hyun Mee
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.5
    • /
    • pp.320-326
    • /
    • 2021
  • This study investigated the effect of the structure of the crosslinking agent used in contact lens polymerization on the physical properties and drug dissolution of contact lenses.es Contact lenses were manufactured using 0.3% and 3% of 4 types of crosslinking agents, respectively, and ofloxacin was used as the drug. Contact lenses using hydrophilic crosslinking agents improved water contents and wettability, and the more hydrophilic functional groups, the greater the effect. Contact lenses with a high concentration of crosslinking agent had a low concentration of eluted drug and a longer release time. The cross-linking agent structure of contact lenses had an effect on improving the performance of contact lenses and controlling drug release.

Comparison of Physical Properties of Domestic Contact Lenses -Focusing on oxygen transmissibility- (국내 생산 콘택트렌즈의 물리적 특성 비교 -산소전달률을 중심으로-)

  • Kim, Ki-Sung
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.393-403
    • /
    • 2018
  • Although the use of silicone hydrogel contact lenses which are known to have high oxygen transmissibility is increasing, they are being sold without any product labeling of physical properties such as water content and oxygen transmissibility. To analyze the physical properties such as the water content and oxygen transmissibility of approved silicone hydrogel contact lenses, this study collected and analyzed the approval information published on the KFDA website. Of 68 cases of domestic silicone hydrogel contact lenses analyzed in this study, 61 cases (89.7%) did not meet the international standard for oxygen permeability. This is because lenses that are not different from hydrogel contact lenses were submitted for approval as silicone hydrogel contact lenses because there is no domestic standard for silicone hydrogel contact lenses. In future, besides the information published on the website, analysis of the physical properties of a wide variety of actual silicone hydrogel contact lenses on the market is required.

The study on the understanding and contentment of training of using soft contact lenses (연성 콘택트렌즈 관리교육의 이해도·만족도 조사)

  • Shin, Jang Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.13-18
    • /
    • 2002
  • This study conducts the soft contact lenses user's understanding and contentment of training while at the place of purchase. It is based on a questionnaire to the residents in and outside the Masan area, aged between ten to thirty, who have worn soft contact lenses. It examines the training of using contact lenses and lens-care products, the period of wearing lenses, exchanging lenses, sterilizing lenses, side effects of using lenses or the periodic examination, and the understanding and contentment of the users during the training. The results of the research are as below : First, the understanding of training of using lenses, using lens-care products, the period of wearing lenses, exchanging lenses was high, but it was low for the training of sterilizing lenses, side effects of wearing lenses or the periodic examination. Second, the contentment of training of using lenses, lens-care products, the period of wearing lenses, exchanging lenses was high, but low for the training of sterilizing lenses, side effects of wearing lenses or the periodic examination. Therefore, the trainer of the contact lenses must easily and sincerely explain sterilizing lenses, the side effects of using lenses and the periodic examination, cheek with the users, and provide guidelines so as to improve the understanding and the contentment of training of using contact lenses.

  • PDF

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

A Study on the Detection of Axis-Rotation in Contact Lenses (콘택트렌즈 회전량 검출에 대한 연구)

  • Lee, Dong-Hee;Kim, Jung-Hee;Cha, Jung-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.255-259
    • /
    • 2005
  • When we wear contact lenses for correcting astigmatism, we often experience the axis-rotation of contact lenses that is happened in case we could not fit the axis of lens exactly or by the eyelid used to blink. In this case, because the exact correcting state becomes in the wrongly correcting state, the asthenopia is led, and the decline of eyesight can be led. For this reason, we need to know axis-rotating degrees of contact lenses. If a contact lens rotated, a residual astigmatism may be detected in the refraction examination after wearing. Using this, we developed a program that calculates the axis-rotating amount of contact lenses.

  • PDF

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Dry Eye Syndrome and Ocular Fatigue according to the Status of Contact Lens Wearing and Management among Female University Students (여대생의 콘택트렌즈 착용 및 관리 실태에 따른 안구건조증과 눈 피로)

  • Her, Sun;Kim, Kye Ha
    • Research in Community and Public Health Nursing
    • /
    • v.25 no.4
    • /
    • pp.259-269
    • /
    • 2014
  • Purpose: The purpose of this study was to examine dry eye syndrome and ocular fatigue according to the status of contact lens wearing and management among female university students. Methods: The subjects were 195 female university students wearing contact lenses. Ocular Surface Disease Index (OSDI) and Virtual Reality Symptom Questionnaire (VRSQ) were used to determine the level of dry eye syndrome and ocular fatigue. The SPSS/WIN 21.0 program was used for analysis of data. Results: Significant differences in the level of dry eye syndrome were observed according to the period of case solution change (F=3.36, p=.037) and the reasons for the change of lens (F=4.56, p=.004). In ocular fatigue, significant differences were observed according to the price of lens (F=3.53, p=.031), rinse in storing lens in a case (t=-2.57, p=.011), and learning about contact lens (t=-2.01, p=.046). A significant positive correlation was observed between dry eye syndrome and ocular fatigue in the subjects. Conclusion: The results of this study show that some subjects have problems in wearing and management of contact lenses. Therefore, an education program related to contact lenses should be provided to contact lens wearers to improve the status of wearing and management of contact lenses.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.