• Title/Summary/Keyword: contact lens material

Search Result 73, Processing Time 0.03 seconds

Polymerization of Hydrogel Contact Lens with High Oxygen Transmissibility (산소투과성이 뛰어난 Hydrogel 콘택트렌즈 합성)

  • Sung, A-Young;Kim, Tae-Hun;Kong, Jung-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.49-53
    • /
    • 2006
  • Acrylate -PDMS(Polydimethylsiloxane)-Urethane Prepolymer is synthesized through treating diisocynate, HEMA(2-hydroxyethylmethacrylate) and bis(hydroxyalkyl)terminated Poly(dimethylsiloxane) having high oxygen permeability under the DBTDL(Dibutylitin dilaurate) catalyst. Modification of HEMA on bis(hydroxyalkyl)terminated Poly(dimethylsiloxane) is to be able to polymerize with other contact lens materials. And modification of urethane on bis(hydroxyalkyl)terminated Poly(dimethylsiloxane) is to increase elastic property and oxygen transmissibility. This material is analyzed by FT-IR and also will be used to make hydrogel contact lens.

  • PDF

Physical Properties Assessment of Soft Contact Lens with Halogen and Carboxylic Substituted Pyridine as Additive (할로겐과 카르복시산으로 치환된 피리딘 첨가제를 사용한 소프트 콘택트렌즈의 물성 평가)

  • Kim, Duck-Hyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.437-443
    • /
    • 2015
  • Purpose: This study evaluated the optical and physical and characteristics of soft contact lens polymerized with addition of 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine-4-carboxylic acid in the basic hydrogel contact lens material. In particular, the utility of 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine- 4-carboxylic acid as a hydrogel contact lens material was investigated. Methods: In this study, 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine-4-carboxylic acid were used as additives. Also, 2-hydroxyethyl methacrylate, acrylic acid, methyl methacrylate and a cross-linker EGDMA were co-polymerized in the presence of AIBN as an initiator. Results: The physical properties of the produced polymers were measured as followings. The water content of 34.54~37.15%, refractive index of 1.4320~1.4342, tensile strength of 0.2872~0.3608 kgf and contact angle of $57.82{\sim}79.57^{\circ}$, UV-B transmittance of 76.8~82.4% and UV-A transmittance of 84.6~86.6% were obtained respectively. Conclusions: Based on the results of this study, contact lens material containing 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine-4-carboxylic acid is expected to be able to used as a material for high wettability and UV-block hydrogel contact lens.

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

The Change in Refractive Powers of Soft Contact Lenses Caused by the Deposition of Tear Proteins (누액 단백질 침착에 의한 소프트콘택트렌즈의 굴절력 변화)

  • Choi, Jin-Yong;Park, Jae-Sung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether refractive powers of soft contact lenses were induced by the deposition of tear proteins when wearing soft contact lenses. Methods: The soft contact lenses (material: etafilcon A, hilafilcon A and comfilcon A) with refractive powers of -1.00 D, -3.00 D, -5.00 D and -7.00 D were incubated in artificial tear for 1 day, 3 days, 5 days, 7 days and 14 days, respectively. After incubation, their refractive powers were measured by wet cell method with an auto-lens meter and their protein deposited on the lenses was determined by the method of Lowry. Results: Among three types of soft contact lenses, the most protein deposition was detected in ionic etafilcon A lens material and significant change of its refractive power was manifested. In other words, refractive powers of etafilcon A lenses firstly decreased after 1 day incubation in artificial tear and then gradually increased with increasing incubation period again. The observed change in refractive powers of all diopters of etafilcon A material was beyond the scope of standard error and bigger in the lens with lower optical power. On the other hand, non-ionic hilafilcon A showed less protein deposition as much as about 20% in etafilacon A and statistically significant increase of refractive powers with increasing incubation period in artificial tear. The change in refractive power of hilafilcon A was also beyond the scope of the standard of error when incubating in artificial tear and greater in the lens with lower diopter. The least protein deposit was shown in silicone hydrogel lens material, comfilcon A as approximately 10% of it in etafilcon A, indicating less change in refractive power within the standard range of error. Conclusions: The large change of refractive powers that was beyond the scope of standard error by the deposition of tear proteins on soft contact lenses was differently detected depending on lens materials in the current study. Thus, the deposition of tear proteins induced by longer period of lens wearing may be one of the causes that induces blurred vision, suggesting that soft contact lens wearers with the amount of tear proteins may need to choose proper lens material.

Preparation and Analysis of High Functional Silicone Hydrogel Lens Containing Metal Oxide Nanoparticles by Photopolymerizaion

  • Heo, Ji-Won;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.32 no.4
    • /
    • pp.193-199
    • /
    • 2022
  • In this study, lenses are fabricated using various nanomaterials as additives to a silicone polymer made with an optimum mixing ratio and short polymerization time. In addition, PVP is added at a ratio of 1 % to investigate the physical properties according to the degree of dispersion, and the compatibility with hydrophobic silicone and the possibility of application as a functional lens material are confirmed. The main materials are SIU as a silicone monomer, DMA, a hydrophilic copolymer, EGDMA as a crosslinking agent, and 2H2M as a photoinitiator. Holmium (III) oxide, Europium (III) oxide, aluminum oxide, and PVP are used. When Holmium (III) oxide and Europium (III) oxide are added based on the Ref sample, the characteristics of the lens tend to be similar overall, and the aluminum oxide shows a tendency slightly different from the previous two oxides. This material can be used as a silicone lens material with various nano oxides and polyvinylpyrrolidone (PVP) acting as a dispersant.

The Status of Contact Lens Wearing, Management and Eye Health Awareness Among Female University Students in Jeju Area (제주지역 여대생들의 콘택트렌즈 착용 및 관리 실태와 눈건강 인식)

  • Choi, Ji Young;Song, Yun Young;Byun, Jong Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.203-214
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the status of contact lens wearing, management and awareness of eye health knowledge among female university students in Jeju area and to utilize the basic data for education and management of contact lens. Methods: Data for this study were collected from the 236 female university students in Jeju area who have a contact lens experience from May 1, 2016 to June 11, 2016. Results: We found the status of contact lens wearing and management of subjects and there were different correlations between discomfort and awareness of eye health knowledge among the subjects who have different characteristics. There were also correlations in discomfort, the average days of contact lens wear per week, initial wearing day and action when they have any discomfort in some contact lens wearers. Conclusions: We realized the status of contact lens wearing and management of female university students and it suggests appropriate contact care education and sustainable management system are need to be established for considering daily average wearing time, the type and material of contact lens wear and main discomfort and so on.

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

Characterization of Hydrogel Tinted Contact Lens Containing 4-iodoaniline using Titanium Silicon Oxide Nanoparticles as Additive (티타늄 실리콘 옥사이드 나노입자를 첨가제로 사용한 4-iodoaniline을 포함한 하이드로젤 착색 콘택트렌즈의 특성)

  • Cho, Seon-Ahr;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.315-322
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic tinted contact lens containing titanium silicon oxide nanoparticles and the basic hydrogel contact lens material containing 4-iodoaniline were examined. In this study, the utility of titanium silicon oxide nanoparticles as a UV-blocking material for ophthalmologic devices were investigated by measuring the UV transmittance of the produced polymer. Also, titanium silicon oxide nanoparticles only without the addition of 4-iodoaniline in primary contact lens materials by copolymerizing two groups were compared. Methods: For manufacturing hydrogel lens, HEMA, MA, MMA, 4-iodoaniline and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. Also, the titanium silicon oxide nanoparticles was used as additive. After polymerization the physical properties such as water content, refractive index, contact angle and spectral transmittance of produced contact lenses were measured. Results: Measurement of the physical properties of the copolymerized material showed that the water content, refractive index, UV-B transmittance and contact angle were in the range of 35.01~38.60%, 1.4350~1.4418, $34.15{\sim}57.25^{\circ}$ and 1.0~10.0%, respectively. Titanium silicon oxide nanoparticles is not used as an additive in the experimental group, the results of the measurement showed that the water content, refractive index, contan angle and UV-B transmittance of the hydrogel lens polymer was 34.00~36.80%, 1.4378~1.4420, $40.15{\sim}60.16^{\circ}$ and 1.8~25.0%, respectively. Conclusions: Also, the transmittance for UV light was reduced significantly in combinations containing titanium oxide nanoparticles.

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

Contact Lens Materials and Applications (콘택트렌즈 소재 및 응용기술)

  • Bae, Woo Ri;Lee, Dong Yun
    • Prospectives of Industrial Chemistry
    • /
    • v.18 no.6
    • /
    • pp.21-28
    • /
    • 2015
  • 콘택트렌즈는 시력 보정의 목적으로 개발되기 시작하여 최근에는 다양한 목적을 위해 이용되고 있다. 특히, 콘택트렌즈를 IT, NT, BT와 융합하여 질병 진단을 목적으로 이용하는데 관심이 높아지고 있다. 본지에서는 콘택트렌즈의 재료와 최근 주목받고 있는 진단용 콘택트렌즈와 소재에 대해 소개하고 앞으로 전망에 대해 논하였다.