• Title/Summary/Keyword: consumption volume

Search Result 564, Processing Time 0.022 seconds

A Study on the Reliability of a Dual Capacity Reciprocating Compressor (이중용량 왕복동 압축기 신뢰성 확보에 대한 연구)

  • Kim, Jong-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.81-90
    • /
    • 2009
  • Due to environmental issues, the development of low energy consumption products has become one of the main topics in the home appliance industry. The energy consumption of a refrigerator depends on the efficiency of its compressor as well as on the refrigerator cycle design, such as the capacity modulation. In this study, a dual capacity, i.e., two-step capacity modulation (TCM), reciprocating compressor is developed. In a TCM compressor, capacity modulation is achieved by changing the dead volume in the cylinder. Instead of a concentric sleeve, an eccentric sleeve, a key, and a spring are used to change the dead volume for the clockwise and counterclockwise rotation of a motor. When the compressor changes its operating mode from full capacity to partial capacity or in opposite direction, the key may collide with the eccentric sleeve. The structural reliability and mode change reliability were confirmed by analysis and experiment.

Estimation of Cardiac Pumping Performance according to the Ventricular Electrical Activation Time Distribution by Using Physiome Model (피지옴 모델을 이용한 심실의 전기활성시간 분포에 따른 심박출 성능평가)

  • Kim, Hyeong-Gyun;Lim, Ki Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.198-203
    • /
    • 2015
  • The purpose of the study is to examine the effects of pacemaker location on cardiac pumping efficacy theoretically. We used a three-dimensional finite element cardiac electromechanical model of canine ventricles with models of the circulatory system. Electrical activation time for normal sinus rhythm and artificial pacing in apex, left ventricular free wall, and right ventricular free wall were obtained from electrophysiological model. We applied the electrical activation time maps to the mechanical contraction model and obtained cardiac mechanical responses such as myocardial contractile ATP consumption, stroke work, stroke volume, ejection fraction, and etc. Among three artificial pacing methods, left ventricle pacing showed best performance in ventricular pumping efficacy.

The Analysis of Energy Cost Adopting an Electric Residence using Historical Energy Consumption Data (에너지소비 데이터를 이용한 전전화 주택 도입시 에너지 사용량 분석)

  • Lee, Jun-Kyu;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Jang, Sung-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • Change of the energy used in a house can be separated from LNG, and electric power. The electric power consumption of a house is more increasing than LNG. The interest for electric houses is rising due to energy saving and low carbon emission. Accordingly, the amount of energies and cost are analyzed consumed in a house using cumulative energy consumption. The result of analysis, amount of electric power, is more increase. In comparison, the use volume of city gas is more decrease. In this paper, the use volume of energy resource is analyzed using historical energy consumption data in the past 25 years. In addition, expected electrical power and heating energy is analysed adopting an Electric Residence.

Development of Export Volume and Export Amount Prediction Models Based on Supervised Learning (지도학습 기반 수출물량 및 수출금액 예측 모델 개발)

  • Dong-Gil Na;Yeong-Woong Yu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.2
    • /
    • pp.152-159
    • /
    • 2023
  • Due to COVID-19, changes in consumption trends are taking place in the distribution sector, such as an increase in non-face-to-face consumption and a rapid growth in the online shopping market. However, it is difficult for small and medium-sized export sellers to obtain forecast information on the export market by country, compared to large distributors who can easily build a global sales network. This study is about the prediction of export amount and export volume by country and item for market information analysis of small and medium export sellers. A prediction model was developed using Lasso, XGBoost, and MLP models based on supervised learning and deep learning, and export trends for clothing, cosmetics, and household electronic devices were predicted for Korea's major export countries, the United States, China, and Vietnam. As a result of the prediction, the performance of MAE and RMSE for the Lasso model was excellent, and based on the development results, a market analysis system for small and medium sellers was developed.

Studies on the Maximal Oxygen Intake of the Korean - Part I. Accuracy of the Measurement of Maximal Oxygen Intake - (한국인(韓國人) 청년남여(靑年男女)의 최대산소섭취량(最大酸素攝取量)에 관(關)한 연구(硏究) - 제(第) I 편(篇) 최대효소섭취양(最大酸素攝取量) 측정치(測定値)의 변리도(變異度)에 관(關)하여 -)

  • Lee, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 1967
  • In order to evaluate the accuracy of the measurement of maximal oxygen intake (MOI), the MOI in seven subjects was determined 3 to 4 times in each individual. Following a 10 minute warm-up on treadmill (4.3 km/hr with 9 degree grade), the subject was asked to run at a speed of 8.73 km/hr on treadmill for a period of 3 minutes at a given grade which was elevated in a step-wise manner from zero to the level of exhaustion. Following a 3 minute run, the subject was allowed to rest for a period of 3 to 5 minutes. During each period of running, several cardio-pulmonary functions were determined and the range of variability for each measurement was computed. The oxygen consumption during the maximal work load was taken as the MOI. The results may be summarized as follows: (1) The minute volume, the oxygen consumption and the heart rate increased linearly until the grade was elevated to 9 degree above which these values were leveled off. (2) The minute volume and the heart rate during maximal exorcise were $87.4{\pm}8.10\;1/min\;and\;187{\pm}3.7$ per minute, respectively. (3) The maximal oxygen intake which corresponds to the oxygen consumption during maximal exercise was averaged to 3.04 1/min. (4) The coefficient of variance for the maximal oxygen intake was 6.32% while the corresponding values for the minute volume and the heart rate during maximal exercise were 5.22 and 2. 14%, respectively.

  • PDF

Estimating Volumes and Expenditures of Inland Water Fish Consumption (내수면어종 소비시장 분석)

  • Lee, Hee-Chan
    • The Journal of Fisheries Business Administration
    • /
    • v.40 no.1
    • /
    • pp.75-96
    • /
    • 2009
  • The objective of this research was to estimate the size of consumption market for inland water fishes. Volumes and expenditures of a total of sixteen fishes consumed in 2007 were estimated based on a module developed. Data were collected through sample surveys of 3,081 households and 291 restaurants dealing with inland water fishes. On the basis of the results, people consumed an estimated 39.5 thousand ton as a whole on inland water fishes. An average person consumed 5.961 times and 1.136kg per year. An annual expenditure of 1,609.7 billion won was estimated. The total was divided 1,450.1 billion won on fishes(90%) and 1,595 billion won on shellfishes(10%). A typical consumer spent 41,668 won on fishes and 4,584 won on shellfishes, averaging about 46,300 won overall. Water eel was top in volumes and expenditure, while mudfish in consumption frequency.

  • PDF

Effect of DLC Coating-layer on Engine Wear Characteristics for Improving Fuel Consumption of Automotive Engine (차량연비 향상을 위한 DLC 코팅 층이 엔진 마모특성에 미치는 영향)

  • Kim, Kee-Joo;Yoo, Seok-Jong;Choi, Byung-Ik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.112-119
    • /
    • 2010
  • Recently, as the matters of environmental pollution, the energy exhaustion and alternative energy source have become more important issues, around industrial countries and the effort to improve fuel consumption is progressed continuously for decrease of air pollution. In an effort to improve fuel consumption for passenger cars, the study of DLC (Diamond Like Carbon) coating which is widely known to good wear characteristics come to the forefront. Therefore, in present study, it was investigated to the influence of DLC coating layer for wear characteristics with the piston ring material and then suggested to the development process for advanced automotive engine parts that showed improved wear characteristics. From these results, Finally, it will be contributed to improve the fuel consumption for passenger vehicles.

Technical Feasibility of Ethanol-Kerosene Blends for Farm Kerosene Engines (에타놀-석유(石油) 혼합연료(混合燃料)의 농용석유(農用石油)엔진에의 이용(利用)에 관(關)한 연구(硏究))

  • Bae, Yeong Hwan;Ryu, Kwan Hee
    • Journal of Biosystems Engineering
    • /
    • v.7 no.1
    • /
    • pp.53-61
    • /
    • 1982
  • As an attempt to reduce the consumption of petroleum resources and to improve the performance of a kerosene engine, a series of experiments was conducted using several kinds of ethanol-kerosene blends under the various compression ratios. The engine used in this study was a single-cylinder, four-cycle kerosene engine having a compression ratio of 4.5. To investigate the feasibility of ethanol-kerosene blends in the original engine, kerosene and blends of 5-percent, 10-percent, and 20-percent-ethanol, by volume, with kerosene were used. And to investigate the feasibility of improving the performance of the kerosene engine, a portion of the cylinder head was cut off to increase the compression ratio up to 5.0 by reducing the combustion chamber volume. Kerosene and blends of 30-percent and 40-percent-ethanol, by volume, with kerosene were used for the modified engine with an increased compression ratio. Variable speed tests at wide-open throttle were also conducted at five speed levels in the range of 1000 to 2200 rpm for each compression ratio and fuel type. Volumetric efficiency, engine torque, and brake specific fuel consumption were determined, and brake thermal efficiency based on the lower heating values of kerosene and ethanol was calculated. The results obtained in the study are summarized as follows: A. Test with the original engine: (1) No abnormal conditions were found when burning ethanol-kerosene blends in the original engine. (2) Volumetric efficiency increased with ethanol concentration in blends. When burning blends of 5-percent, 10-percent, and 20-percent ethanol, by volume, with kerosene, average volumetric efficiency increased 1.6 percent, 2.6 percent, and 4.1 percent respectively, than when burning kerosene. (3) Mean engine torque increased 5.2 percent for 5-percent-ethanol blend, 9.3 percent for 10-percent-ethanol blend, and 11.5 percent for 20-percent-ethanol blend than for kerosene. Increase in engine torque when using ethanol-kerosene blends was due to the improved combustion characteristics of ethanol as well as an increase in volumetric efficiency. (4) Up to ethanol concentration of 20 percent, mean brake specific fuel consumption was nearly constant inspite of the difference in heating value between ethanol and kerosene. (5) Brake thermal efficiency increased 0.3 percent for 5-percent-ethanol blend, 3.8 percent for 10-percent-ethanol blend, and 6.8 percent for 20-percent-ethanol blend than for kerosene. B. Test with the modified engine with an increased compression ratio: (1) When burning kerosene, mean volumetric efficiency, engine torque, and brake thermal efficiency were somewhat lower than for the original engine. (2) Engine torque increased 15.1 percent for 30-percent-ethanol blend and 18.4 percent for 40-percent-ethanol blend than for kerosene. (3) There was no significant difference in brake specific fuel consumption regardless of ethanol concentration in blends. (4) Brake thermal efficiency increased 15.0 percent for 30-percent-ethanol blend and 19. 5 percent for 40-percent-ethanol blend than for kerosene.

  • PDF

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析))

  • Seo, Youn-Kyu;Kim, Joo-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF

Energy Consumption and Exercise Effect of University Students During Automatic Stepper Exercise

  • MOON, Hwang-woon;CHOI, Youn-Jin
    • The Korean Journal of Food & Health Convergence
    • /
    • v.7 no.6
    • /
    • pp.17-24
    • /
    • 2021
  • This study investigates the exercise-physiological changes in stages through the movement of the automatic stepper and to analyze the usefulness of the automatic stepper. For 18 male university students, out of 10 levels, 5 level and 10 level of automatic stepper exercise were performed. At each 10, 20, 30 minutes during exercise, 5 and 10 minutes after exercise stop the subjects were examined to analyze the changes in energy consumption after minutes, respiratory exchange rate, heart rate, oxygen consumption per body weight, METs, cumulative energy consumption, and lactic acid to verify the usefulness of the automatic stepper. The mean and standard deviation were calculated using the SPSS, and one-way ANOVA with repeated measure was performed to verify the difference in the mean between time periods. The LSD method was used for the post-hoc test, and the significance level was set to α = .05. There were no significant changes in both 5 and 10 level, but the cumulative energy consumption over time increased significantly. In addition, as a low-intensity exercise intensity is shown, a low increase in lactic acid indicated a safe exercise level. In future studies, in-depth studies of various variables through regular exercise programs are needed for those who need safe exercise.