• Title/Summary/Keyword: consumption electric energy

Search Result 632, Processing Time 0.027 seconds

A Study on the Analysis of Energy Consumption in University Campuses (종합대학 캠퍼스의 에너지 소비현황 분석에 관한 연구)

  • Jung, Jae-Woong;Kim, Dong-Woo;Seok, Ho-Tae;Yang, Jeong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.175-180
    • /
    • 2009
  • Today, the amount of energy consumption at the university campuses is huge. The effort for the energy consumption reduction in university campuses is certainly needed by the following reason; first, contribution for the reduction request about green house gas emission. Second, energy cost reduction in university campus. Third, emotional spreading influence consideration as the maximum higher educational institutions. For the energy consumption reduction in university campus, the energy consumption analysis of current situation has to be executed. The energy reduction possibility in which it exists in university campus can be understood through the energy consumption analysis. And the application is possible as fundamental data of the policy establishment for the effective energy reduction in university campuses. This research analyzed the energy consumption present state of the major university campus of the Korea as the fundamental research for the energy consumption reduction plan preparation of the university campus. Moreover, surveys were performed and analyzed for the energy manager in charge of the university campus.

  • PDF

Washing Efficiency of Drum Washing Machine Using Steam Jet System (스팀분사 방식을 사용한 스팀 드럼세탁의 세탁성능)

  • Jung, Sun-Young;Jang, Jeong-Dae;Park, Seok-Kyu;Jeong, Seong-Hae
    • Fashion & Textile Research Journal
    • /
    • v.8 no.1
    • /
    • pp.134-138
    • /
    • 2006
  • The washing efficiency of two types of washing machine- drum(drum washing) and drum using steam jet system(steam drum washing) was studied. The purpose of this paper is to clarify the performance of new steam drum washing. The relationship between washing temperature and washing efficiency(reflectance(%)) by soil removal, and that between washing temperature and electric energy consumption, Fabric damage evaluated by Danish wear method, Fabric shrinkage(%) during laundering were investigated, and compared with those in drum washing machine. Washing efficiency of steam drum washing according to washing temperature is better than that of drum washing. Electric energy consumption and fabric damage in steam drum washing are lower than those of drum washing. Fabric damage increased as washing temperature increased. Shrinkage of fabrics in steam drum washing and drum washing are about same. Therefore, we assumed that in the case of steam drum washing using steam jet system, washing efficiency remarkably increased, and fabric damage decreased, even with a lot of saving in given electric energy and water used.

An Improved Zone-Based Routing Protocol for Heterogeneous Wireless Sensor Networks

  • Zhao, Liquan;Chen, Nan
    • Journal of Information Processing Systems
    • /
    • v.13 no.3
    • /
    • pp.500-517
    • /
    • 2017
  • In this paper, an improved zone-based routing protocol for heterogeneous wireless sensor networks is proposed. The proposed protocol has fixed the sized zone according to the distance from the base station and used a dynamic clustering technique for advanced nodes to select a cluster head with maximum residual energy to transmit the data. In addition, we select an optimal route with minimum energy consumption for normal nodes and conserve energy by state transition throughout data transmission. Simulation results indicated that the proposed protocol performed better than the other algorithm by reducing energy consumption and providing a longer network lifetime and better throughput of data packets.

Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer (곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究))

  • Keum, Dong Hyuk;Lee, Yong Kook;Lee, Kyou Seung;Han, Jong Ho
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

A Study on Effect of Applying Energy Storage System on SeoulMetro Line 2 (에너지저장시스템의 서울메트로 2호선 적용 효과에 관한 연구)

  • An, Cheon-Heon;Lee, Han-Min;Kim, Gil-Dong;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.966-971
    • /
    • 2009
  • The recent environmental protection trend requires more strict energy saving, therefore every transportation system should reduce energy consumption to the minimum value. High-efficiency operation system, energy saving and CO2 emissions shall be addressed as important issue in railway system. These issues are the most essential factors of railway, compared to major public transportation system. Recently, saving energy in the electric railway system has been studied. For such new energy saving, the Energy storage system is considered for saving energy. Energy saving is possible by efficient use of regenerated energy. Regenerated energy is recycled amongst vehicles by mean of charge and discharge corresponding to powering and braking of electric vehicle operations. This energy saving contributes to cut CO2 to reduce greenhouse gas emissions. Recycling regenerated energy demonstrate significant effect on peak cut of consumption energy in railway substation. Absorption of excess energy avoids regeneration failure due to high traction voltage. This paper presents effects by applying the energy storage system to SeoulMetro Line 2.

  • PDF

Change of Main Body Temperature and Reduction of Energy Consumption in a 1 Tube 2 Chamber Bent Silkworm Type Dyeing Machine

  • Lee, Choon-Gil;Woo, Kyung-Sung
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.550-556
    • /
    • 2002
  • The changes of the main body temperature of a I tube 2 chamber bent silkworm type dyeing machine and the reduction of energy consumption of the dyeing machine by the energy saving design are reported. This dyeing machine was developed for the purpose of the energy saving and high efficiency. In this study, the changes of the main body temperature of the 1 tube 2 chamber bent silkworm type dyeing machine were studied experimentally. Especially the effect of the blower motor electric current and the main body pressure at various blower frequencies were studied experimentally. In the experimental data for the changes of main body temperature, it was shown that the main body temperature increased as the blower motor electric current and the main body pressure increased.

A Study on Monthly Electric Energy Estimation of Pole-Transformer Using NLRE Curve (NLRE 곡선을 이용한 주상 변압기 월간 사용전력량 추정에 관한 연구)

  • Im, Jin-Soon;Yun, Sang-Yun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.58-60
    • /
    • 2000
  • In this paper we present an estimation method of electric energy[kWh] for load management of pole-transformer. For the electric energy estimation, we use the nonlinear load research based estimation(NLRE) algorithm. The NLRE curve is the normalized annual cumulative energy consumption for a particular day in a year. And, it is used for the coefficient estimation. Estimation method of suggested electric energy of pole-transformer used billing cycle electric energy estimation equation is verified as comparison billing cycle electric energy and estimated electric energy. We can reduce the error of peak load estimation by suggested method than the conventional method in domestic.

  • PDF

Prediction of the Effect of Cooling Fan Electrification on City Bus (냉각팬 전동화에 따른 시내버스 연비효과 예측)

  • Lee, Yongkyu;Park, Jinil;Lee, Jonghwa
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.908-912
    • /
    • 2013
  • Because of their longer operating times and larger size relative to conventional fans, the cooling fans mounted in buses consume larger amounts of energy. Most of the cooling fans mounted in a bus are connected to the engine by a viscous clutch. A viscous cooling fan's speed is determined by its fluid temperature, which is affected by the air flow through the radiator. The fan does not react immediately to the coolant temperature and in doing so causes unnecessary energy consumption. Therefore, the fuel economy of buses using viscous fans can be improved by changing to an electric cooling fan design, which can be actively controlled. In addition, electric power consumption is increased by using electric cooling fans. Thus, when electric fans are applied in conjunction with the alternator management system (AMS), the fuel economy is further enhanced. In this study, simulations were performed to predict coolant temperature and cooling fan speeds. Simulations were performed for both viscous and electric cooling fans, and power consumption was calculated. Additionally, fuel economy was calculated applying both the alternator management system and the electric cooling fan.

A Study on Energy Storage System for Low Carbon, Green Growth of Electric Railway System (전기철도시스템의 저탄소 녹색성장을 위한 에너지저장시스템에 관한 연구)

  • Lee, Han-Min;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1161_1162
    • /
    • 2009
  • The recent environmental protection trend requires more strict energy saving, therefore every transportation system should reduce energy consumption to the minimum value. High-efficiency operation system, energy saving and $CO_2$ emissions shall be addressed as important issue in railway system. These issues are the most essential factors of railway, compared to major public transportation system. Recently, saving energy in the electric railway system has been studied. For such new energy saving, the energy storage system is considered for saving energy. Energy saving is possible by efficient use of regenerated energy. Regenerated energy is recycled amongst vehicles by mean of charge and discharge corresponding to powering and braking of electric vehicle operations. This energy saving contributes to cut $CO_2$ to reduce greenhouse gas emissions. Recycling regenerated energy demonstrate significant effect on peak cut of consumption energy in railway substation. Absorption of excess energy avoids regeneration failure due to high traction voltage. Therefore, the energy storage system is needed to be adopted to use regeneration energy when the vehicle is braking.

  • PDF

The Power Consumption analysis of the metropolitan Electric Multiple Unit for a Route (수도권 전동열차 노선별 소비전력량 분석)

  • Kim, Jin-Woo;Son, Kyong-So;Jang, Hee-Ju;Kim, Ho-Soon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.619-626
    • /
    • 2011
  • In this paper, while electric multiple unit is moving on the rail, the content of measuring and analysing electric power consumption is mentioned. In order to measure the electric power consumption, we developed the power record analysis equipment and installed it the inside of the converter and inverter system to record the electric power consumption measured by voltage sensor and current sensor. Moving on the rail, we analysed traction power used up and regenerative power by using the measuring instrument. We expect that the measured and analysed data will offer basic research material to devise a energy reduction plan and introduce a new EMU system with high efficiency.

  • PDF