• Title/Summary/Keyword: consumption efficiency

Search Result 2,986, Processing Time 0.034 seconds

Deinking of White Ledger with Ultrasonic Wave : Laboratory Scale Trial

  • Won, Jong Myoung
    • Journal of Forest and Environmental Science
    • /
    • v.23 no.2
    • /
    • pp.73-78
    • /
    • 2007
  • Ultrasonic deinkings of white ledger were carried out to confirm whether the ink removal efficiency and pulp qualities can be improved by the ultrasonic deinking. The effects of conventional pulping and ultrasonic treatment of white ledger on the ink particle size distribution and ink removal coefficient were compared. The physical properties of paper, energy consumption and effluent qualities were measured. The ultrasonic treatment of white ledger resulted in the ink particle size distribution suitable for flotation. The ink removal efficiency, brightness, breaking length and effluent quality were improved by the ultrasonic deinking. It is expected that the competitiveness of ultrasonic deinking system can be improved by the optimization of treatment condition.

  • PDF

A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window (슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF

A Study on Ozone Generation Characteristic using Ba-Ti-Si Ceramic Tube (Ba-Ti-Si 세라믹 방전관의 오존 발생 특성 연구)

  • 이동훈;박홍재;박재윤
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.634-640
    • /
    • 2003
  • This paper is to be researched into ozone generation character of Bi-Ti-Si type high dielectric yield ceramic catalyst discharge tube. And conditions of basic experiment are the outside diameter of discharge tube : 52 mm, the length of discharge tube : 350 mm, the frequence : 900 Hz, the temperature of cooling water : 25 $^{\circ}C$, quantity of flow : 5, 10, 20 l/min, pressure : 1.2, 1.4, 1.6 atm, and distance of discharge gap : 0.4, 0.6, 0.8 mm. Ozone generation characteristics were measured to consumption power. At quantity of flow : 20 l/min, discharge gap : 0.6 mm, pressure : 1.6, and consumption power : 150 W, Maximum ozone generation efficiency of 175 g/kWh was obtained. Maximum ozone generation efficiency was measured below the flow quantity of 20 l/min at below pressure of 1.6 atm. However, Maximum ozone generation efficiency was measured over the flow quantity of 20 l/min at over pressure of 1.6 atm.

The Effect of Exhaust System Components on the Sl Engine Performance (배기구성요소가 SI기관의 성능에 미치는 영향)

  • Park Kyoungsuk;Park Sejong;Son Sungman
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.192-198
    • /
    • 2005
  • Recently, Automobile manufacturers regarding stability, economic environmental-friendly problems by the development of automobile. This reason is increasingly strict environmental regulations to lower fuel consumption and reduce emission. Designing more efficient and low emission control exhaust system results in more efficient Performance, reduced back Pressure and higher convert efficiency. Also to reduce the noise and the vibration of the automobile. According to develop variable type muffler, dual muffler and active intelligence exhaust system unit. Improvement in engine performance and fuel consumption rate, higher conversion efficiency demand information of pressure fraction and heat characteristics. To be able to determine these factor fur we experiment on each case of exhaust system unit. In this study, how back pressure is distributed in flow-through in exhaust system and how to design exhaust system flexibleness, efficiency, lower back pressure and optimal performance. This study furnish basic data for engineers, technicians.

Duty Cycle Research for Energy Consumption Efficiency under the IoT Wireless Environment

  • Woo, Eun-Ju;Moon, Yu-Sung;Choi, Ung-Se;Kim, Jung-Won
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1210-1213
    • /
    • 2018
  • In this paper, we propose a method to reduce the amount of current through the Timing Control of the duty cycle and the Report Attribute Control at the MAC Layer in consideration of the Sleep Mode under the IoT wireless environment. The use of a duty cycle is an effective way to reduce energy consumption on wireless sensor networks where the node is placed in sleep mode periodically. In particular, we studied how to control power efficiency through duty rate in Short Transition Time and ACK Time processing while satisfying radio channel limitation criterion. When comparing before and after the improvement considering the delay time constraint, we validated the correlation of the electrical current reduction.

Energy-efficient mmWave cell-free massive MIMO downlink transmission with low-resolution DACs and phase shifters

  • Seung-Eun Hong;Jee-Hyeon Na
    • ETRI Journal
    • /
    • v.44 no.6
    • /
    • pp.885-902
    • /
    • 2022
  • The mmWave cell-free massive MIMO (CFmMIMO), combining the advantages of wide bandwidth in the mmWave frequency band and the high- and uniform-spectral efficiency of CFmMIMO, has recently emerged as one of the enabling technologies for 6G. In this paper, we propose a novel framework for energy-efficient mmWave CFmMIMO systems that uses low-resolution digital-analog converters (DACs) and phase shifters (PSs) to introduce lowcomplexity hybrid precoding. Additionally, we propose a heuristic pilot allocation scheme that makes the best effort to slash some interference from copilot users. The simulation results show that the proposed hybrid precoding and pilot allocation scheme outperforms the existing schemes. Furthermore, we reveal the relationship between the energy and spectral efficiencies for the proposed mmWave CFmMIMO system by modeling the whole network power consumption and observe that the introduction of low-resolution DACs and PSs is effective in increasing the energy efficiency by compromising the spectral efficiency and the network power consumption.

A study on hybrid solar LED street light system (하이브리드 태양광 LED 가로등 시스템 연구)

  • Lee, Dong-Hyuk
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.20-25
    • /
    • 2022
  • In line with the rapid economic growth of many countries, fossil fuel energy sources are also rapidly depleting. Therefore, the price is also rising rapidly, so it is necessary to develop new and renewable energy sources such as hydropower, geothermal power, nuclear power, wind power and solar energy to replace fossil fuel energy in the future. In this study, development of rotating concentrator module system, development of rotating module control control system, development of lamp and charge control controller, configuration and prototype production of rotating concentrating solar LED street light system, efficiency of rotating concentrating solar LED street light, and power production. The research was conducted in the order of evaluation of comprehensive performance tests such as consumption and consumption. As a result, the developed high-efficiency rotation-concentrating hybrid solar LED street light module system has a 50% higher light-gathering efficiency than existing products by tracing sunlight by self-developing a rotation-collecting module on existing solar LED street lamps according to the characteristics of Korea's topography. and the power generation was improved by more than 40%.

A study on particle collection efficiency of a low power consumption two-stage electrostatic precipitator for oil mists collection (오일 미스트 포집을 위한 저전력 소비형 2단 전기집진기의 집진효율에 대한 연구)

  • Song, Chi-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.834-843
    • /
    • 2014
  • A two-stage electrostatic precipitator (ESP) using a carbon brush charger and a plate-plate parallel aluminum collector was developed and its application for removal of oil mist aerosols was investigated. Charge number per particle and particle collection efficiency at different applied voltage to the carbon brush charger were measured and compared to those obtained by theoretical calculations. A long-term operation of the ESP during 9 weeks was also performed to evaluate its performance durability for oil mists. Average charge number per mist particle increased with the applied voltage to the charger, and thus the collection efficiency of the mist particles also increased overall at the particle size range of 0.26 - 3 mm. The tendencies of the average charge number per particle and particle collection efficiency obtained from theoretical calculations were considerably consistent with those of the experimental results. Particle collection efficiency of ~99 % at 0.3 mm could be achieved by power consumption of only 0.0033 W/($m^3/h$) at the face velocity of 1 m/s and its collection performance maintained stably during every 8 hr operation per day for 9 weeks with little increase of pressure drop.

Operation of Electrodialysis at Over Limiting Current Density (한계전류밀도 이상에서 전기투석공정의 운전)

  • 박진수;최재환;문승현
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.171-181
    • /
    • 2002
  • The parameter which determines the plateau length of current-voltage curve for ion- exchange membranes was studied at various concentrations of NaCl and different flow rates. Moreover, the feasibility of the electrodialytic removal of 0.1 M NaCl solution at various current densities was tested by assessing the electrodialysis performance parameters such as salt removal efficiency, current efficiency, energy consumption and water dissociation. The diffusion boundary layer (DBL) thickness decreased with the NaCl concentration and flow rate of fled solution and it was observed that the plateau length of current-voltage curves was related with the DBL thickness. The removal efficiency and current efficiency were not affected significantly by the current densities even at the overlimiting current region indicating that most current were passed by electrolyte, and water dissociations are not responsible for the overlimiting current. Energy consumption increased when the current density supplied exceeded the limiting current density (LCD) values, because additional energy was necessary to overcome the plateau potential. Beyond the LCD values the energy consumption required to get a certain removal efficiency was not affected by the current density applied. The result suggests that it is allowed to operate electrodialysis processes at as high as possible current density unless water-splitting does not occur.

Evaluation of electrical energy consumption in UV/H2O2 advanced oxidation process for simultaneous removal of NO and SO2

  • Shahrestani, Masoumeh Moheb;Rahimi, Amir
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.389-396
    • /
    • 2019
  • The electrical energy consumption (EEC) in removal of NO by a $UV/H_2O_2$ oxidation process was introduced and related to removal efficiency of this gas. The absorption-reaction of NO was conducted in a bubble column reactor in the presence of $SO_2$. The variation in NO removal efficiency was investigated for various process parameters including NO and $SO_2$ inlet concentrations, initial concentration of $H_2O_2$ solution and gas flow rate. EEC values were obtained in these different conditions. The removal efficiency was increased from about 22% to 54.7% when $H_2O_2$ concentration increased from 0.1 to 1.5 M, while EEC decreased by about 70%. However, further increase in $H_2O_2$ concentration, from 1.5 to 2, had no significant effect on NO absorption and EEC. An increase in NO inlet concentration, from 200 to 500 ppm, decreased its removal efficiency by about 10%. However, EEC increased from $2.9{\times}10^{-2}$ to $3.9{\times}10^{-2}kWh/m^3$. Results also revealed that the presence of $SO_2$ had negative effect on NO removal percentage and EEC values. Some experiments were conducted to investigate the effect of $H_2O_2$ solution pH. The changing of pH of oxidation-absorption medium in the ranges between 3 to 10, had positive and negative effects on removal efficiency depending on pH value.