• Title/Summary/Keyword: construction management(CM)

Search Result 440, Processing Time 0.028 seconds

Management Guidelines on the Large Old Trees as the Natural Monuments in Seoul, Incheon, and Gyeonggi Province through the Analysis of the Growing Environment (생육환경 분석을 통한 서울·인천·경기지역 천연기념물 노거수의 관리방안)

  • Lee, Seung Je
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.1
    • /
    • pp.88-99
    • /
    • 2009
  • This study was conducted to formulate management guidelines for Natural monumental old trees in Korea through survey of tree vigor and analysis of growing environments. A total of 20 old trees designated as natural monuments in Seoul, Incheon, and Gyeonggi Province were surveyed. The biological characteristics were surveyed with 4 items of species, ages and height of trees. The surrounding environments were surveyed with 2 items of location types and surroundings. The root conditions were surveyed with 2 items of denudation and molding depth. The health conditions were surveyed with 5 items of withering rate, cavity size, bark breakaway rate, damages by blight and insects, and growing tips. The soil conditions were surveyed with 6 items of PH, organic contents, valid phosphoric acid, transposal cations(K, Ca) and soil compaction. On the basis of outcomes of these research items, mutual relations among locations, growings and soil conditions of old trees were analyzed by carring out cross tabulation, correlation, and simple and multiple regression. Management guidelines were presented searching the factors effecting on the health of the monumental old trees. On the biological characteristics, the old trees designated as natural monuments were Pinus bungeana(4 trees), Juniperus chinensis(3 trees), Ginkgo biloba(3 trees), Poncirus trifoliata(2 trees). Actinidia arguta, Wisteria floribunda, Thuja orientalis, Quercus mongolica, Sophora japonica, Fraxinus rhynchophylla, Zelkova serrata, and Pinus densiflora. The tree height ranged from 4.2 to 39.2m, and root collar rounds ranged from 1.01 to 15.2m. On the surrounding environments, The location types ; Gardens(4), historical sites(5), residental sections(3) open agricultural fields(3), mountain hills(3), and near ocean beaches(1) and stream site(1). The surroundings ; 75% denudation of roots, molded more than 10cm except 4 trees(25%). On the health conditions, 1)Withering rate ; Ginkgo biloba(20%) in Yongmoon temple, (5%) in Saki-ri, kanwha-gun, and others had no withering rate. 2) Cavity size ; all subject had $5{\sim}100cm^3$ of cavity. 3) Bark breakaway rate ; Pinus bungeana in Soosong-dong, in the shrine of Confucius, in Samchung-dong, especially high rate of cavity(5~50%) in Seoul area and in Saki-ri, Kangwha-gun were high 45% brakeaway rate. 4) Damages by blight and insects was slight due to managements. 5Growing tips ; In cases of Juniperus chinensis in Changdeok palace and SunnogDang, seoul, growing tips were 1/2, presumably cause by air pollution, and in cases of Fraxinus rhynchophylla in Paju city and Pinus densiflora in BacksaDorip-ri, Icheon city, growing tips were fine, presumably because there were no moldings. On the Soil conditions, Soil pH ranged from 5.2 to 8.3, organic matter contents from 12% to 56%, phosphorus contents from 104 to 618ppm, soil compaction ranged from 7 to 28mm( among them, Denudation was severe with 21~28mm soil compactions in cases of Pinus bungeana in Soosong -dong, Thuja orientalis in Samchung -dong, Ginkgo biloba in the shrine of Confucius and in Yongmoon temple.) Results of cross tabulation, correlation, and regression analysis showed that molding depth was the most serious factor to deteriorate the tree vigor and cambium conductivity. In addition, soil acidity, organic matter contents, disease and insect damages and cambial detachment were also related to the tree vigor. Additional research of these relationships will be needed to conduct more detailed studies. Based on the relationships between the tree vigor and growing environments, it is considered that old trees should be managed to give them more growing spaces and less abuses. Also, molded soils should be removed and further soil-molding around the tree collar should be prohibited. For the construction of systematic management and removal of harmful factors, appropriative management according to spices, persistent monitering of damaged cases and construction of management system through the accumulation of data on the relationships of soil conditions are required.

The Effect of Connected Bioretention on Reduction of Surface Runoff in LID Design (LID 설계시 식생체류지간 연결에 의한 강우유출수 저감 효과분석)

  • Jeon, Ji-Hong;Seo, Seong-Cheol;Park, Chan-Gi
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.562-569
    • /
    • 2016
  • Recently, Low Impact Development (LID) is being used in Korea to control urban runoff and nonpoint source pollution. In this study, we evaluated the reduction of surface runoff from a study area, as the effect of connecting three bioretention as LID-BMP. Surface runoff and storage volume of bioretention is estimated by the Curve Number (CN) method. In this study, the storage volume of bioretention is divided by the volume of surface runoff and precipitation which directly enters the bioretention. The ratio of captured surface runoff volume to storage volume is highly influenced by the ratio of drainage area to surface area of bioretention. The high bioretention surface area-to-drainage area ratio captures more surface runoff. The ratio of 1.2 captures 51~54% of the total surface runoff, ranging from 5-30cm of bioretention depth; a ratio of 6.2 captures 81~85%. Three connected bioretentions could therefore captures much more runoff volume, ranging from $35.8{\sim}167.3m^3$, as compared to three disconnected bioretentions at their maximum amount of precipitation with non-effluent from the connecting three bioretentions. Hence, connecting LID-BMPs could improve the removal efficiencies of surface runoff volume and nonpoint source pollution.

A Case Study of Electronic-blasting, Railroad Tunnel to Pass under Existing Highway (기존 고속도로 하부 통과를 위한 철도터널 전자발파 시공사례)

  • Kim, Gab-Soo;Son, Young-Bok;Kim, Jae-Hoon
    • Explosives and Blasting
    • /
    • v.32 no.2
    • /
    • pp.16-24
    • /
    • 2014
  • In this "Wonju~Jaecheon double-lanes railroad" project, a highway is located at about 13meter above a tunnel. Initially, rock-splitting method was used for the tunnel excavation in order to minimize the possible damage on the highway. The method, however, takes a long time for the tunnel excavation and that may cause other problems like large displacement of tunnel and subsidence of highway ground before the tunnel can be stabilized by supporters. Therefore, the application of electronic blasting method(eDdevII) was recommended to control the blast vibration below 1.0cm/sec as well as to prevent the subsidence of highway ground. The analysis of the influence of tunnel excavation on the highway showed that electric blasting method is permissible for the safe management of the highway. Based on that, the tunnel construction under a highway could be carried out quickly and safely without any damages on the highway.

The Evaluation of Water Quality in Coastal Sea of Saemangeum by Chemical Environmental factors (새만금 하구역의 이화학적 환경요인에 따른 수질 평가)

  • Kim, Jae-Ok;Kim, Won-Jang;Jo, Kuk-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.5
    • /
    • pp.57-65
    • /
    • 2007
  • The objective of this study was to evaluate chemical water quality by hourly monitoring(25hr) of Saemangeum esturary. For this study, we selected 2 sites like a Mangyong Bridge(St. 6) and Dongjin Bridge(St. 7). Inflow of salt water was not detected during low tide(maximum 553, 508cm) of all stations, while the salinity rises were detected in spring tide(750cm). When 602m of maximum tide was reached, salinity concentration was increased at St. 7, while there was no change in St. 6. Therefore, We know that salinity variation is greatly influenced by tide height at survey site. Also, significant variance of salinity(p<0.05) was found between St. 6 and St. 7 because dike construction made the flood tide move into the Dongjin river. Total suspened solids(TSS) concentration was increased because of the river runoff at St. 6, and also the turbulance and resuspension according to salt intrusion at St. 7. During the high tide, the water discharge from the sea seemed to dilute the nutrient but to elevate TSS concentration in St. 7. Silicate and nitrate concentrations in the studied site were decreased by the mixing of sea water, whereas the evident trend of phosphate concentration was not found. This result can be explained by the phosphorus condition. Phosphorus exists inactive when it is affected by hydrated iron and adsorbed onto suspended matters. Compared to the environmental conditions of the St. 6 and St. 7, physical factors such as temperature, dissolved oxygen and TSS have statistically no significant difference(p<0.001), but nutrient concentrations were higher at St. 6 than St. 7. It could be suggested from these results that it is important to control the discharge of fresh water by sewage treatment plants located in St. 6 for water quality management.

Study on Application of PIR-D(Pile Installation Recorder-Driven Pile) in Driven Pile (항타 말뚝에서 항타관리시스템(Pile Installation Recorder-Driven Pile)의 적용성에 관한 연구)

  • Park, Bong-Keun;Park, Min-Cheul;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.28-35
    • /
    • 2004
  • Driven pile has the excellent bearing characteristics and good economics, so it is known as the comparative piling method. To use the advantages of driven pile fully, it is necessary to perform the proper construction management. Engineers must drive pile to the proper bearing layer with proper blow energy and measure the blow count and penetration per certain depth to analyze the bearing capacity and driveability. In conventional method, these parameters have been measured manually so it was difficult to get good accuracy. After PIR-D(Pile Installation Recorder-Driven Pile) was attached to the driving equipment, the hammer efficiency, blow count and penetration in blow/10cm were measured automatically. In this paper, to givethe rational judgement criteria of bearing layer, driveability, blow/10cm according to pile depth during pile driving, the some relationship between the driving resistance and ground layer distribution was analyzed. The ground investigation during piles (PHC ${\Phi}450,\;{\Phi}400\;&\;Steel\;Pile\;{\Phi}609{\ast}16t$) installation in the marine clay layer in Incheon, the sandy soil layer in Yongin and the tuff layer in Pusan was done. And measuring hammer efficiency not doing recently, we could compare hammer efficiency(Eh) by PIR-D and energy transfer ratio(ETR) by Pile Dynamic Analyzer(PDA).

  • PDF

Assessment of Fence Height to Prevent Roadkill of Water Deer(Hydropotes inermis) (고라니(Hydropotes inermis)의 로드킬(Roadkill) 방지 울타리 적정 높이 평가)

  • Park, Heebok;Woo, Donggul;Song, Eui-Geun;Lim, Anya;Lee, Bae-Keun;Jang, Ji-Deok;Park, Tae-Jin;Choi, Tae-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.2
    • /
    • pp.232-239
    • /
    • 2018
  • Our study aims to provide a guideline of deer-proof fence heights to prevent roadkill of water deer (Hydropotes inermis), the most frequently killed by a vehicle collision, in South Korea. With 27 water deer in deer ecology center of the National Institute of Ecology, we measured the ability of water deer to jump gradually higher fences from 0.5cm by 10cm until the deterrence rate reached 100%. Ourresultrevealed that the deterrence rate became 96.7% at the fence height of 1.5m and the rate reached 100% at the 1.8m. We believe that our result provides the fundamental information to prepare a standard of deer-proof fence height. This evidence-based standard will contribute to improving the guideline for wildlife crossing construction and management, established by Ministry of Environment Korea.

Comparative assessment of age, growth and food habit of the black-chinned tilapia, Sarotherodon melanotheron (Rüppell, 1852), from a closed and open lagoon, Ghana

  • Zuh, Cephas Kwesi;Abobi, Seth Mensah;Campion, Benjamin Betey
    • Fisheries and Aquatic Sciences
    • /
    • v.22 no.12
    • /
    • pp.31.1-31.12
    • /
    • 2019
  • Background: The black-chinned tilapia, Sarotherodon melanotheron, is the most abundant fish species in the Nakwa (an open lagoon) and Brenu (a closed lagoon) in the Central Region of Ghana. Aspects of the life history characteristics and the ecology of the fish populations in both lagoons were studied to assess the bio-ecological status of this important resource. Methods: Fish samples were obtained from fishermen that fish on the Nakwa and Brenu lagoons using cast, drag and gill nets. The age of the fish was assessed from otoliths analysis and its growth modelled following the von Bertalanffy growth function. Morphometric characteristics of the fish populations were analysed using power regression and ANOVA for parameters comparisons, and Student's t test to determine whether species grew isometrically. The percentage occurrence method was used to analyse the stomach contents of the fish. Results: A total of 382 fish samples from both lagoons were measured, comprising 209 from Nakwa lagoon and 176 from Brenu lagoon. The size and weight of fish samples ranged between 3.9-11.5 cm total length and 1.0-27.3 g for Nakwa Lagoon and 5.6-12.8 cm total length and 3.2-29.8 g for the Brenu Lagoon. The estimated von Bertalanffy growth parameters were L∞ = 12.04 cm and K = 2.76/year for the Nakwa Lagoon samples and L∞ = 13.44 cm and K = 3.27/year for Brenu Lagoon samples. Daily otolith incremental rate ranged from 0.01-0.03 mm per day to 0.01-0.02 mm per day for Nakwa and Brenu lagoons, respectively. Stomach content analysis of the fish samples revealed that the species are planktivorous and the range of food varied between the lagoons. Green algae were the most prevalent food item in the stomachs of the fish samples from Nakwa with the frequency of 69% whilst diatoms (80.5%) were most prevalent phytoplanktonic food item for the fish in Brenu lagoon. Conclusions: The estimates of asymptotic length for the species in both lagoons are close to known values of the species length at first sexual maturity and points to intensive fishing pressure. As a consequence, a comprehensive sample-based survey is required in both lagoons to derive estimates of management reference points. The results of the stomach content analysis are beneficial to the construction of diet matrix for ecosystem models of the two systems.

Construction of Spatial Information and Growth Status of All Tree Individuals in the Gyerim Historical Site, Gyeongju (문화재로서 경주 계림 내 생육수목 현황 및 공간정보 구축 연구)

  • Hong, Suk-Hwan;An, Mi-Yeon;Kang, Rae-Yeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.5
    • /
    • pp.1-13
    • /
    • 2017
  • This study was intended to provide management directions through the provision of tree spatial information as basic data for the preservation of Gyerim(legal historical site), which is located in Gyeongju city, Gyeonsangnam-do, Korea. As a result of the survey of the entire forest, there are a total of 25 species and 510 individuals growing trees. Of these species, 14 species are native and 14 are introduced species. Apart from Sophora japonica, Zelkova serrata, Celtis sinensis, most of the introduced species were adopted without historical basis after designation as a historical site. By a ratio of 36% to introduced species(including 3% of naturalized species; Ailanthus altissima), the historical heritage was significantly damaged. Gyerim, which has over 2,000 years of history, has a total 15 individuals(2.9%) large trees(over 100cm DBH). Ten of these are Salix glandulosa, and in the past, most of this area was considered a Salix glandulosa forest. Currently, however, there are many small trees(under 20cm DBH) for the next generation of growth and the Salix glandulosa forest will continue to decline. Furthermore, most small trees were afforested, so the historicity and place features as a mythological forest will quickly fade.

Effect of Dissolved Oxygen (DO) on Internal Corrosion of Water Pipes

  • Jung, Hae-Ryong;Kim, Un-Ji;Seo, Gyu-Tae;Lee, Hyun-Dong;Lee, Chun-Sik
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.195-199
    • /
    • 2009
  • A series of laboratory-scale corrosion experiments was carried out to observe the effect of dissolved oxygen (DO) in the presence of other water quality parameters, such as hardness, Cl-, and pH using various pipe materials. In addition, a simulated loop system was installed at a water treatment plant for pilot-scale experiment. Laboratory-scale experiment showed that corrosion rates for galvanized steel pipe (GSP), carbon steel pipe (CSP), and ductile cast iron pipe (DCIP) were decreased to 72%, 75%, and 91% by reducing DO concentration from 9${\pm}$0.5 mg/L to 2${\pm}$0.5 mg/L. From the pilot scale experiment, it was further identified that the average ionization rate of zinc in GSP decreased from 0.00533 to 0.00078 mg/$cm^2$/d by controlling the concentration of DO. The reduction of average ionization rate for copper pipe (CP) and stainless steel pipe (SSP) were 71.4% for Cu and 63.5% for Fe, respectively. From this study, it was concluded that DO could be used as a major parameter in controlling the corrosion of water pipes.

Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater (오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발)

  • Cho, Heuy-Nam;Choi, Sang-Il
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2009
  • The compressed packer device is designed to improve the underground contamination prevention facilities of ground water wells. As for the device, the installation is simple because of the safety lock device and the compression of the casing are simple the installation is simple. There is no leakage of ground water because the pressure resistance with $4.5\;kg/cm^2$ makes it equipped with the watertightness The single casing is installed and the reaming for grouting is possible with 300 mm excavation so that installation cost can be saved. Silicon rubber is used for the compressed packer so that the extension rate is 590%. In terms of environmental pollution, it is an environmental friendly product which does not contain harmful ingredients such as Pb, Cd, and phenol. below the standard or undetectable level Furthermore, the installation costs are 35 to 62% or lower than the conventional grouting construction method and are 87% or lower than the expansion packer construction method, the new environmental technology No.47 Also, the device is designed to meet the relevant regulations such as Rules on Preserving the Ground Water Quality, The Standard on Jeju Island Ground Water Development and Facility Installation and Management, and The Plan and Guideline on Operating and Managing the Small-Scale Tap Water Facilities of Ministry of Environment and Ministry of Food, Agriculture, Forestry and Fisheries.