• Title/Summary/Keyword: construction engineers

Search Result 4,550, Processing Time 0.034 seconds

Wave Analysis and Spectrum Estimation for the Optimal Design of the Wave Energy Converter in the Hupo Coastal Sea (파력발전장치 설계를 위한후포 연안의 파랑 분석 및 스펙트럼 추정)

  • Kweon, Hyuck-Min;Cho, Hongyeon;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • There exist various types of the WEC (Wave Energy Converter), and among them, the point absorber is the most popularly investigated type. However, it is difficult to find examples of systematically measured data analysis for the design of the point absorber type of power buoy in the world. The study investigates the wave load acting on the point absorber type resonance power buoy wave energy extraction system proposed by Kweon et al. (2010). This study analyzes the time series spectra with respect to the three-year wave data (2002.05.01~2005.03.29) measured using the pressure type wave gage at the seaside of north breakwater of Hupo harbor located in the east coast of the Korean peninsula. From the analysis results, it could be deduced that monthly wave period and wave height variations were apparent and that monthly wave powers were unevenly distributed annually. The average wave steepness of the usual wave was 0.01, lower than that of the wind wave range of 0.02-0.04. The mode of the average wave period has the value of 5.31 sec, while mode of the wave height of the applicable period has the value of 0.29 m. The occurrence probability of the peak period is a bi-modal type, with a mode value between 4.47 sec and 6.78 sec. The design wave period can be selected from the above four values of 0.01, 5.31, 4.47, 6.78. About 95% of measured wave heights are below 1 m. Through this study, it was found that a resonance power buoy system is necessary in coastal areas with low wave energy and that the optimal design for overcoming the uneven monthly distribution of wave power is a major task in the development of a WEF (Wave Energy Farm). Finding it impossible to express the average spectrum of the usual wave in terms of the standard spectrum equation, this study proposes a new spectrum equation with three parameters, with which basic data for the prediction of the power production using wave power buoy and the fatigue analysis of the system can be given.

The Treatment of Heavy Metal-cyanide Complexes Wastewater by Zn$^{+2}$/Fe$^{+2}$ Ion and Coprecipitation in Practical Plant (II) (아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(II))

  • Lee, Jong-Cheul;Lee, Young-Man;Kang, Ik-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.524-533
    • /
    • 2008
  • Industrial wastewater generated in the electroplating and metal finishing industries typically contain toxic free and complex metal cyanide with various heavy metals. Alkaline chlorination, the normal treatment method destroys only free cyanide, not complex metal cyanide. A novel treatment method has been developed which destroys both free and complex metal cyanide as compared with Practical Plant(I). Prior to the removal of complex metal cyanide by Fe/Zn coprecipitation and removal of others(Cu, Ni), Chromium is reduced from the hexavalent to the trivalent form by Sodium bisulfite(NaHSO$_3$), followed by alkaline-chlorination for the cyanide destruction. The maximum removal efficiency of chromium by reduction was found to be 99.92% under pH 2.0, ORP 250 mV for 0.5 hours. The removal efficiency of complex metal cyanide was max. 98.24%(residual CN: 4.50 mg/L) in pH 9.5, 240 rpm with 3.0 $\times$ 10$^{-4}$ mol of FeSO$_4$/ZnCl$_2$ for 0.5 hours. The removal efficiency of Cu, Ni using both hydroxide and sulfide precipitation was found to be max. 99.9% as Cu in 3.0 mol of Na$_2$S and 93.86% as Ni in 4.0 mol of Na$_2$S under pH 9.0$\sim$10.0, 240 rpm for 0.5 hours. The concentration of residual CN by alkaline-chlorination was 0.21 mg/L(removal efficiencies: 95.33%) under the following conditions; 1st Oxidation : pH 10.0, ORP 350 mV, reaction time 0.5 hours, 2nd Oxidation : pH 8.0, ORP 650 mV, reaction time 0.5 hours. It is important to note that the removal of free and complex metal cyanide from the electroplating wastewater should be employed by chromium reduction, Fe/Zn coprecipitation and, sulfide precipitation, followed by alkaline-chlorination for the Korean permissible limit of wastewater discharge, where the better results could be found as compared to the preceding paper as indicated in practical treatment(I).

Reduction of Carbon-Dioxide Emission Applying Carbon Capture and Storage(CCS) Technology to Power Generation and Industry Sectors in Korea (국내 전력 발전 및 산업 부문에서 탄소 포집 및 저장(CCS) 기술을 이용한 이산화탄소 배출 저감)

  • Wee, Jung-Ho;Kim, Jeong-In;Song, In-Sung;Song, Bo-Yun;Choi, Kyoung-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.961-972
    • /
    • 2008
  • In 2004, total emissions of Greenhouse Gases(GHGs) in Korea was estimated to be about 590 million metric tons, which is the world's 10th largest emissions. Considering the much amount of nation's GHG emissions and growing nation's position in the world, GHG emissions in Korea should be reduced in near future. The CO$_2$ emissions from two sub-sections of energy sector in Korea, such as thermal power plant and industry section(including manufacturing and construction industries), was about 300 million metric tons in 2004 and this is 53.3% of total GHG emissions in Korea. So, the mitigation of CO$_2$ emissions in these two section is more important and more effective to reduce the nation's total GHGs than any other fields. In addition, these two section have high potential to qualitatively and effectively apply the CCS(Carbon Capture and Storage) technologies due to the nature of their process. There are several CCS technologies applied to these two section. In short term, the chemical absorption technology using amine as a absorbent could be the most effectively used. In middle or long term, pre-combustion technology equipped with ATR(Autothermal reforming), or MSR-$H_2$(Methane steam reformer with hydrogen separation membrane reactor) unit and oxyfuel combustion such as SOFC+GT(Solid oxide fuel cell-Gas turbine) process would be the promising technologies to reduce the CO$_2$ emissions in two areas. It is expected that these advanced CCS technologies can reduce the CO$_2$ avoidance cost to $US 8.5-43.5/tCO$_2$. Using the CCS technologies, if the CO$_2$ emissions from two sub-sections of energy sector could be reduced to even 10% of total emissions, the amount of 30 million metric tons of CO$_2$ could be mitigated.

Evaluation of Grade-Classification of Wood Waste in Korea by Characteristic Analysis (국내 폐목재 특성분석을 통한 등급화 평가)

  • Kim, Joung-Dae;Park, Joon-Seok;Do, In-Hwan;Hong, Soo-Youl;Oh, Gil-Jong;Chung, David;Yoon, Jung-In;Phae, Chae-Gun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1102-1110
    • /
    • 2008
  • This research was performed to analyze the characteristics of wood wastes from origin and to suggest grade-classification for them. Korean proximate analysis was conducted, and heating value, heavy metals and Cl concentrations were analyzed for gradeclassification. Wood wastes were sampled from forest, living, construction and demolition, and industrial areas with origin. Moisture content of most wood wastes was ranged in 5$\sim$10%. VS (volatile solids) and ash contents of them showed > 95% and < 5%, respectively. Most wood wastes except wood for growing mushroom permitted the standard (low heating value $\geq$ 3,500 kcal/kg) for refusederived fuel. CCA (Cr, Cu, As) concentration of wood wastes used in bench, wasted fishing boat, and railroad crosstie was higher than that of the other ones. Cl content showed approximately 1.3% in wood box for fish and $\leq$ 0.2% in the other wood wastes. Cl content of all wood wasted used in this research permitted the standard (Cl $\leq$ 0.2%, dry weight basis) for refuse-derived fuel. If the wood wastes were classified in 3-grade, plywoods would be in 2nd grade, and MDF (medium density fiber), wooden bench, painted electric wire drum, wasted fishing boat, and railroad crosstie be in 3rd grade.

The Research of Storage Capacity & Sedimentation of Reservoirs in HONAM Province (호남지방에 저수지의 매몰상황과 저수량에 관한 조사연구(농학계))

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.2
    • /
    • pp.2262-2275
    • /
    • 1971
  • Fourteenes rervoirs maintained by the local land improvement associations in the province of Chullabuk-Do and 20 reservoir maintained by thos in the province of Chullanam-Do, were surveyed in connection with a correction between storage capacity and sediment deposit. In addition to this survey, 3,347 of small reservoir, that lie scattered around in the above-mentioned two provinces were investigated by using existing two provinces were investigated by using existing records pertaining to storage capacity in the office of City and country, respectively. According to this investigation the following comclusions are derived. 1. A sediment deposition rate is high, being about $10.63m^3/ha$ of drainage area, and resulting in the average decreasc of storage capaity by 27.5%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of trees. Easpecially, in small reservoir, an original average design storage depth of 197mm in irrigation water depth is decreased to about 140mm. 2. An average unit storage depth of 325.6mm as the time of initial construction is decreased to 226mm at present. This phenomena causes a greater shortage irrigation water, since it was assumed that original storage quantity was already in short. 3. Generally speaking, seepage rates through dam abutment intakepipe, etc, are high due to insufficient maintenance and management of reservoir. 4. It is recommended that sediment deposit should be dredged when a reservoir is dry in drought. 5. Farmers usually waste excessive irrigation water. 6. Water saving methods should be practiced by applying only necessary water for growing stage of rice. 7. In are as where water defficiency for irrigation is severe, a soil moisture content should be kept at about 70% by applying water once in several days. 8. Tube wells should be provided so as to exploit ground water and subsurface current below stream bed as much as possible. 9. If an intake weir was constructed, a water collection well should be built for the use in drought. 10. Water conservation should be forced by converting devastated forests contained in the drainage area of reservoir to protected forests so as to take priority of yrefor estation, gully control, the prohibition of disorderly cutting of trees, etc. 11. Collective rice nurseries should be adopted, and it should be recommended that irrigation water for rice nurseries is supplied by farmer themselves. 12. Sediment desposit in reservoir should be thoroughly dreged so as to secure a original design storage capacity. 13. The structure of overflow weir should be automatic so as to freely control flood level and not to increase dam height.

  • PDF

Analysis of the Utilization Characteristics of Electrical Power and Equipments on the Farms (농촌의 전력및 전기기기의 이용특성분석)

  • 박승우;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3943-3955
    • /
    • 1975
  • The purposes of this study are to evaluate the utilization characteristics of electrical power consumption, to grasp the present trends in the use of electrical equipments, to estimate the demand factor and load factor being held, and to evaluate the efficiency of electical uses for the recently electrified farms cultivating paddy rice. For the purposes, 109 sample farms located in eleven villiages electrified in six different years from 1968 to 1973, were chosen at random and investigated on 35 items concerning to electrical uses and wiring systems. The survey was carried out in 1975, in the vinicity of Suweon city. The results are summarized as follows: i) The average annual power consumption on sample farms is considered to be low, being 242.9 Kwh. in 1974, and varied according to the different electrified year and size of cultivated land, respectively. It has significant positive correlation to the area of farm, too. ii) Between the number of year of electrical uses and the power consumption, there is very significant positive correlation, which could be expressed as Y=43.041+16.108 X, where X represents the number of years of electrical uses. The annual increment of power consumption is much greater at the beginning of the electrification than that at the later years, its average being approximately 20 percent. However, it is recommended that any estimation of long-term increments should be carefully investigated. iii) The monthly power consumption varies considerably throughout a year, in which the heaviest farm load occurs in November. Observing the seasonal variation of consumption, the winter-time is the heaviest season while the summer is the lowest. The result implies house lighting is chief contribution to the present electrical consumption on the farms. Comparing the variation of monthly consumption ratios between the sample farms and industries, the electrical uses on the farms are independant of the industrial uses, and further, the agricultural uses are of inverse pattern to the farms from the results that there is negative correlationship between them, iv) The number of electrical equipments used on the farms are occupied chiefly by lighting sources. Next to the lighting sources, household appliances of small quantity and some motors are used. The mean electrical quantity is about 1, 127.4 watt, which corresponds to about 37.6 per cent to the contracted quantity. The composition of quantity is chiefly occupied by the electrical motor of about 1.5 hp., single-phased. The number of the annual utilization hours of each equipment is tabulated in Table IV-5. In contradiction to the high utilization of lighting sources and small household appliances, the motor is poorly used for approximately 22 hours in a year. v) More than 55 per cent of farms want to purchase new electrical equipments such as small household appliances and electrical motors in their number. The impulse of purchasing such items is stimulated by the contacts to the mass media and their knowledge on such equipments. Consequently, the increase of electrical uses could be prompted by such trials as education and demonstration. vi) The demand and load factors on the farms vary considerably according to the greater variation of the power consumption, daily or monthly. The daily demand factor is 22.4 per cent and load factor 18.6 per cent, while the annual demand factor is 1.3 per cent and load factor 70 per cent approximately. Therefore, the low efficiency of construction cost requires re-evaluation of the present contracted quantity of 3 Kw. or increase of electrical uses. vii) The electrical energy on the farms devoted chiefly to lighten the farm residences does not contribute to the farm incomes. Consequently, the cost of electrical consumption presses considerably upon the farm economy. Therefore, there is great need to build up the electrical uses on the farms through the development of new works and techinques to utilize any electrical equipments on the production of farm products. Further more, such the development should be related to increase the actual income of the farm consumers.

  • PDF

Development of Visible Light Responsive Nitrogen Doped Photocatalysts ($TiO_2$, $Nb_2O_5$) for hydrogen Evolution (수소 생산을 위한 가시광선 감응 질소 도핑 $TiO_2$$Nb_2O_5$ 광촉매의 개발)

  • Choi, Mi-Jin;Chae, Kyu-Jung;Yu, Hye-Weon;Kim, Kyoung-Yeol;Jang, Am;Kim, In-S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.907-912
    • /
    • 2011
  • Development of visible light responsive photocatalysts is a promising research area to facilitate utilization of solar energy for hydrogen production via photocatalytic water splitting. In this study two groups of samples, nitrogen (N)-doped niobium pentoxide ($Nb_2O_5$) and titanium dioxide ($TiO_2$) ($Nb_2O_5-N$, $HNb_3O_8-N$, $TiO_2-N$) and N-undoped ones ($Nb_2O_5$ and $TiO_2$) were tested. In order to utilize visible light, nitrogen atoms were doped in selected photocatalysts by using urea. A shift of the absorption edges of the Ndoped samples in the visible light region was observed. Under visible light irradiation, N-doped samples were more prominent photocatalytic activities than the N-undoped samples. Specifically, 99.7% of rhodamine B (RhB) was degraded after 60 minutes of visible light irradiation with $TiO_2-N$. Since $TiO_2-N$ shows the highest activity of RhB degradation, it was supposed to generate the highest current response. However, $HNb_3O_8-N$ showed the highest current response ($63.7mA/cm^2$) than $TiO_2-N$. More interestingly, when we compare the hydrogen production, $Nb_2O_5-N$ produced $19.4{\mu}mol/h$ of hydrogen.

A Study on Scenario to establish Coastal Inundation Prediction Map due to Storm Surge (폭풍해일에 의한 해안침수예상도 작성 시나리오 연구)

  • Moon, Seung-Rok;Kang, Tae-Soon;Nam, Soo-Yong;Hwang, Joon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.492-501
    • /
    • 2007
  • Coastal disasters have become one of the most important issues in every coastal country. In Korea, coastal disasters such as storm surge, sea level rise and extreme weather have placed many coastal regions in danger of being exposed or damaged during subsequent storms and gradual shoreline retreat. A storm surge is an onshore gush of water associated with a tow pressure weather system, typically in typhoon season. However, it is very difficult to predict storm surge height and inundation due to the irregularity of the course and intensity of a typhoon. To provide a new scheme of typhoon damage prediction model, the scenario which changes the central pressure, the maximum wind radius, the track and the proceeding speed by corresponding previous typhoon database, was composed. The virtual typhoon scenario database was constructed with individual scenario simulation and evaluation, in which it extracted the result from the scenario database of information of the hereafter typhoon and information due to climate change. This virtual typhoon scenario database will apply damage prediction information about a typhoon. This study performed construction and analysis of the simulation system with the storm surge/coastal inundation model at Masan coastal areas, and applied method for predicting using the scenario of the storm surge.

Study of Geological Log Database for Public Wells, Jeju Island (제주도 공공 관정 지질주상도 DB 구축 소개)

  • Pak, Song-Hyon;Koh, Giwon;Park, Junbeom;Moon, Dukchul;Yoon, Woo Seok
    • Economic and Environmental Geology
    • /
    • v.48 no.6
    • /
    • pp.509-523
    • /
    • 2015
  • This study introduces newly implemented geological well logs database for Jeju public water wells, built for a research project focusing on integrated hydrogeology database of Jeju Island. A detailed analysis of the existing 1,200 Jeju Island geological logs for the public wells developed since 1970 revealed six major indications to be improved for their use in Jeju geological logs DB construction: (1) lack of uniformity in rock name classification, (2) poor definitions of pyroclastic deposits and sand and gravel layers, (3) lack of well borehole aquifer information, (4) lack of information on well screen installation in many water wells, (5) differences by person in geological logging descriptions. A new Jeju geological logs DB enabling standardized input and output formats has been implemented to overcome the above indications by reestablishing the names of Jeju volcanic and sedimentary rocks and utilizing a commercial, database-based input structured, geological log program. The newly designed database structure in geological log program enables users to store a large number of geology, well drilling, and test data at the standardized DB input structure. Also, well borehole groundwater and aquifer test data can be easily added without modifying the existing database structure. Thus, the newly implemented geological logs DB could be a standardized DB for a large number of Jeju existing public wells and new wells to be developed in the future at Jeju Island. Also, the new geological logs DB will be a basis for ongoing project 'Developing GIS-based integrated interpretation system for Jeju Island hydrogeology'.

Evaluation of Filtration and Backwash Efficiency of Non-point Source Pollution Reduction Facility (장치형 비점오염원 저감시설의 여과 및 역세 효율 평가)

  • Yun, Sangleen;Lee, Yong-Jae;Ahn, Jae-Hwan;Choi, Won-Suk;Lee, Jungwoo;Oh, Hye-Cheol;Kim, Seog-Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.664-671
    • /
    • 2017
  • Non-point source pollution is the emission source that unspecifically releases pollutants to water system from unspecific places such as cities, agricultural lands, mountains, and construction sites and its discharge path is not easily identified. Also, it is difficult to design and manage the reduction facilities for the emission quantity is primarily affected from weather conditions like rainfall. Since 2006, the significance of non-point source pollution reduction has been grown in Republic of Korea and this reinforces needs for the installation of reduction facilities. However, because the standards for the installation details and reduction efficiency are not clarified by law, people are preferring technologies that do not require particular maintenance and high expenses. The purpose of this study is to examine and maintain the efficiency of non-point source pollutants reduction facility which uses expended polypropylene as a media. The higher the depth of the media, the less range of variations in the reduction efficiency was observed and the final efficiency was also increased. When the media depth was 60 cm, the average reduction efficiency was 94% and 90% where linear velocities were 10 m/hr and 20 m/hr respectively. The results from 180 minutes operation in 10 m/hr and 20 m/hr of linear velocities were slightly different in head loss changes which were caused by media depth variations. The backwash experiments which were conducted in triplicate showed the reduction efficiency decreased as the time went on because of the media clogging. However, it was found that after the backwashing the reduction efficiency was increased as effective as the efficiency of the initial filtration.