• Title/Summary/Keyword: constant flux

Search Result 637, Processing Time 0.021 seconds

Simulated Distribution Characteristics of Surface Temperature on Irradiating of a Laser

  • Lee, Young-Wook;Yeon, Sang-Ho
    • International Journal of Contents
    • /
    • v.5 no.2
    • /
    • pp.16-19
    • /
    • 2009
  • In this paper, we concern about the distribution characteristics of surface temperature by the increment of time, diffusivity and heat flux on irradiating of a laser. The penetration depth corresponding to the induced constant heat flux or irradiated laser, is simulated by a computer algorithm. The distribution of temperature versus penetration depth for the variation of time and diffusivity is characterized at the constant heat flux and on irradiating of a laser. The temperature of constant heat flux at the fixed diffusivity or time, is decreased by the pattern of exponential function as the time t or diffusivity a is increased (a=10, 100, 1000). The temperature of constant heat flux is not changed but exponentially fixed with the increasing diffusivity and the fixed time. On the other hand, the temperature of laser at the fixed diffusivity or time is decreased linearly. Our results show that the characteristics of the simulated surface temperature in a semi-infinite solid are similar to the graphs on theoretical consideration.

A Study on Calibration of Heat Flux Sensor by using Convective Heat Transfer (대류방식을 이용한 열유속센서의 검정에 관한 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1358-1363
    • /
    • 2004
  • The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of $1.4{\sim}2.5kW/m^2$. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ${\pm}2.07%$. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.

  • PDF

Measurement Bias of Heat Flux Gauge based on Calibration Constant supported by Manufacturer (제조사 보정상수에 기인한 열유속계의 측정 오차)

  • Kim, Sung-Chan;Hamins, Anthony
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • As a preliminary study to quantify the measurement uncertainty of the Schmidt-Boelter type heat flux gauge, the present study has been conducted to evaluate the measurement error due to the calibration constant supported by manufacturer. Calibrations of heat flux gauges are performed at NIST Fire Research Division using a calibration facility with heat source of a 2000 W halogen-tungsten filament lamp and the calibration constant is obtained by comparing the response of the reference and a standard heat flux gauge at the same irradiance conditions. Calibration for heat flux gauges made by three different manufacturers is compared with their factory calibration constant. Relative error due to fluctuation of output signal from heat flux gauges does not exceed 1% of the mean value and the relative error between calibration of this study and factory calibration constant ranged from 1.5% to 14.3%. The present study shows that a continuous and periodic calibration is necessary for accurate heat flux measurement.

Rotor Time Constant Compensation of Induction Motor by Estimating Deviation Angle (회전자 자속 이탈각 추정을 이용한 유도전동기의 회전자 시상수 보상)

  • Cha, Young-Kil;Jung, Jong-Jin;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.264-267
    • /
    • 1995
  • In indirect vector control, if the value or the rotor tine constant used in slip calculation is different from the actual rotor time constant because of the temperature rising and flux saturation level, model flux angle and actual flux angle is different so that the transient and steady state response is degraded. In this paper, flux deviation angle is calculated by using actual torque and reference torque, and this flux deviation angle is summed to slip angle, therefore rotor flux angle is always accurate and indirect vector control is satisfied.

  • PDF

A Study of Hear Flux and Instantaneous Temperature According to the Initial Tamperature of Combustion Chamber in a Constant Volume Combustion Chamber (연소실 초기온도 변화에 따른 순간열유속에 관한 연구)

  • Lee, Chi-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.3
    • /
    • pp.193-200
    • /
    • 2003
  • In the production of internal combustion engines, there has been a move towards the development of high performance engines with improved fuel efficiency, lighter weight and smaller sizes. These trends help to answer problems in engines related to thermal load and abnormal combustion. In order to investigate these problems, a thin film-type probe for instantaneously measuring temperatures has been suggested. A method for manufacturing such a probe was established in this study. The instantaneous surface temperature of a constant volume combustion chamber was measured by this probe and the heat flux was obtained through Fourier analysis. In order to thoroughly understand the characteristics of combustion, the authors measured the wall temperature of the combustion chamber and computed heat flux through a cylinder wall while varying the protrusion height of the probe. For achieving the above goals, a instantaneous temperature probe was developed, thereby making possible the analysis of the instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

  • PDF

Rotor Time Constant Estimation for Induction Motor Direct Vector Control (유도전동기 직접벡터제어를 위한 회전자 시정수 추정)

  • Bae Sang-Jun;Choi Jong-Woo;Kim Heung-Geun;Lee Hong-Hee;Chun Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.113-118
    • /
    • 2003
  • The proposed rotor time constant estimation method can be applied to the direct vector control system of induction motor with flux observer In this paper the flux observer proposed by Gopinath model are used. This paper presents a new scheme for on-line estimation of rotor time constant using estimated rotor flux phase and current model rotor flux phase. The major advantage of this method are its dynamic correction capability, simplicity and accuracy as well as independence from change in motor parameter. simulation results are presented which demonstrate the effectiveness of the on line rotor time constant estimation.

  • PDF

Rotor Time Constant Compensation of Vector Controlled Induction Motor Using Stator Current and Flux Error (고정자 전류와 자속의 오차를 이용한 벡터제어 유도전동기의 회전자 시정수 보상)

  • 김우현;박철우;임성운;권우현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.5
    • /
    • pp.367-375
    • /
    • 2000
  • It is proposed that the rotor time constant and inductance are compensated at the same time in the indirect vector control method of an induction motor. The proposed scheme compensates the rotor time constant using the difference between the Q-axis real stator current and estimated current that is calculated from the terminal voltage and current, and compensates inductance by using the difference between the D-axis real stator flux and estimated stator flux in the synchronous rotating reference frame. Although the rotor time constant and inductance vary at once, the proposed method compensates the rotor time constant and inductance with accuracy. In addition to, two variables can be compensated not only at the steady state condition, but also at the transient state, where the torque varies in a rectangular pulse waveform. Therefore, the performance of vector control is greatly improved as verified by experiment.

  • PDF

Study on the Heat Flux Using Instantaneous Temperature as Height of Probe in the Combustion Chamber (연손실 순간온도 측저에 있어서 돌출높이에 따른 실험적 연구)

  • 이치우;김지훈;김시범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.395-402
    • /
    • 2001
  • The gasoline engine tends to high performance, fuel economy, small-sized. Therefore, it is necessary to solve the problems on thermal load, abnormal combustion, etc, in the engine, Thine film instantaneous temperature measurement probe was made. And the manufactural method of probe was established. The instantaneous surface temperatures in the constant volume combustion chamber were measured by this probe and the heat flux was obtained by Fourier analysis. The authors measured the wall temperature of combustion chamber and computed the heat flux through the cylinder wall in order to understand the combustion characteristics depending on height of probe. For achieving this goal, the thin film instantaneous temperature probe was developed for analyzing the instantaneous surface wall temperature and unsteady heat flux on the constant volume combustion chamber.

  • PDF

Slip Frequency Andative Tunning for the Compensation of Rotor Resistance Variation of Induction Motor (유도전동기의 회전자저항 변동 보상을 위한 슬립주파수의 적응 조정)

  • 이일형;이윤종
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.42-48
    • /
    • 1994
  • A rotor flux error-based approach for correcting the rotor time constant estimation used in the slip frequency calculator of indirect field oriented controller is presented in this paper. The controller was derived from the d-q induction machine model. Slip frequency gain is dependent on the machine parameter errors. And parameter errors result in rotor flux error. Thus, estimated rotor flux is compared to commanded rotor flux. The error between them is used for the estimation of rotor time constant. Simulation results which demonstrate the performance of this approach are presented.

  • PDF

A Study on Sinewave Air Gap Flux Density of Surface Type Magnet Motor (표면부착형 영구자석 전동기의 정현파 공극자속밀도 연구)

  • Kim, Hyun-Cheol;Kim, Jang-Mok;Kim, Cheul-U
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1571-1576
    • /
    • 2007
  • This report describes the analytical characteristic of sinewave air gap flux density for the brushless AC motor with surface permanent magnet. The analysis of sinewave air gap flux density is the key to expect the performance of back EMF for the design of brushless AC motor. The numerical analysis and FEM analysis are performed to adopt radial and parallel flux magnetization of magnet on the rotor. And it is also executed to vary the magnet arc angle and arc radius for the condition of constant and non constant air gap. This report is focused on the characteristic of sinewave air gap flux density for permanent magnet of surface brushless AC motor. This results also have more reliable data against the previous paper which had the representative numerical analysis of air gap flux density[1][2].