• 제목/요약/키워드: constant current source

검색결과 252건 처리시간 0.031초

정전력 열차 모델을 이용한 AT급전 시스템 해석 (Analysis of AT Feeding System using Constant Power Model for Train)

  • 김백
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1327-1331
    • /
    • 2004
  • In this paper constant power models for electric trains have been used to analyze the steady states of the AT feeding systems. There are some previous studies utilizing constant impedance models or constant current models. These mentioned models are easy to use, but even so they don't yield exact results because of the innate restraints of the models since linear models cannot represent the characteristic of constant power in inverter-driven trains. It is reasonable that the train be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. Nonlinear equations which reflect constant power model for train have been developed by considering mutual impedances between wires and AT's turn-ratio of 1:1, then these equations have been solved by N-R iterative method. The proposed method doesn't need any specific assumptions through either the process of developing equations or the process of acquiring solutions, so it can be said to be stricter than other conventional methods.

  • PDF

암치료용 레이저 시스템 개발 (The development of laser system for cancer)

  • 이동진;김주명;김선학;임현수
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 하계학술발표회
    • /
    • pp.154-155
    • /
    • 2001
  • A laser system for therapy of cancer is proposed in this paper. In order to accuracy and statistical output control we used the constant current control method and designed the power source to protect the resonator from the over -current, rush-current and electrical fault. The most important things are the radiation type for cancer therapy in laser system, we developed the radiation type of cw, pulse, and burst pulse. The experimental result show that laser beam power increase linearly from 100mW to 300mW for input current increasing and the exposure time.

  • PDF

회생차량을 포함한 급전시스템 해석 알고리즘 (The Computer Algorithm for DC Traction Power Supply System Analysis Including Regenerative Braking Vehicles)

  • 정상기;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.639-646
    • /
    • 2003
  • Nowadays traction motors in the urban rail transit vehicle are controlled by VVVF inverter and have capability of regenerative braking. The algorithms to deal with the regenerating vehicle in simulation for the DC traction power supply is introduced in this paper. Substations have to be separated from the system to represent reverse biased rectifiers in substations. The model of the trains in regenerative braking has to be changed from the ideal current source to the constant voltage source since the train input voltage has to be controlled below the certain train maximum voltage. Some mismatches are unevitable because the constraint of the regenerated power can not be imposed with the constant voltage source. The mismatches represent the unused regenerated power. A computer program is developed to verify the validity of the algorithm. The test run result shows the program behaves as it is expected and proves the algorithm's validity.

One Chip Microcomputer를 이용한 유도전동기 구동용 3동 전류형 인버어터시스템 (The Triple Current Source Inverter System for Induction Motor Drive Using a One Chip Microcomputer)

  • Chung, Yon-Tack;Jang, Seong-Chil;Hwang, Lak-Hoon;Lee, Hoon-Goo
    • 대한전기학회논문지
    • /
    • 제40권2호
    • /
    • pp.162-172
    • /
    • 1991
  • In proportion to the capacity enlargement of the induction motor system controlled by current source inverter, the capacitance of the commutating capacitor is enlarged and then the spike value of output voltage is increased at the moment of charge and discharge. Moreover, the output currnet includes a number of harmonic components. Such voltage spike and harmonics generate the torque ripple and lead to bad effects on the performance of the induction motor. In this study, all the harmonics excluding 17th and 19th harmonics were mostly elimunated by adopting 18-phase Triple High Frequency Current Source Inverter(HFCSI), and the spike component of output voltage was reduced by adding the Voltage Clamping Circuit(VCC). As a result, the torque ripple and the commutation loss were reduced and the performance of the system was improved. Experiments for speed control were carried out in the tripple current source inverter system for induction motor drive. Overall system was controlled by ONE CHIP MICROCOMPUTER(INTEL 8751). Control circuits were simplified and good experimental results in the constant V/F control were obtained due to the flexibility of the microcomputer.

  • PDF

단일 전원을 이용한 LED 전류-전압 공급 및 측정 시스템의 효율적인 구현 (Efficient Implementation of LED Current-voltage Source and Measurement System Using Single Power)

  • 박창희;안태영;조성호
    • 전자공학회논문지
    • /
    • 제52권5호
    • /
    • pp.183-189
    • /
    • 2015
  • 본 논문에서는 LED에 전류 또는 전압을 공급하고, 이에 따라 나타나는 전기적 특성을 분석하는 시스템에서 기존의 (+),(-) 전류 또는 전압을 공급하는 방식과 (+),(-) 전류 또는 전압을 측정 방식에서, 회로의 오차를 감소시키고, 하드웨어의 복잡도를 개선시킬 수 있으며, 시스템의 보정을 절반으로 줄일 수 있는 방법으로 (+) 단일 전원을 이용하여 전류 또는 전압을 공급하고, 측정할 수 있는 방법을 제안한다.

Average Current Controlled X-Y Channel Driving White LED Backlight System for 46" LCD TV

  • Cho, Dae-Youn;Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woo;Yang, Byung-Choon;Jang, Tae-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2008
  • A novel white-LED (light emitting diode) backlight system for 46"LCD TVs which involves the average current controlled X-Y channel driving method is proposed, which is composed of 1 converter and row and column channel switches. In the conventional X-Y channel driving driven with a constant voltage source, the driving current of LED increases because the threshold voltage of LED decreases when LED temperature goes up. To maintain the luminance of backlight constant, the average current controlled X-Y channel driving will be employed. Finally the results are confirmed by experimental results.

  • PDF

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

무정전전원장치용 단상 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Single Phase Voltage Source Inverter Used for Uninterruptible Power Supply)

  • 민완기;김재식;최재호
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.83-89
    • /
    • 2007
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

제어기응답을 고려한 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller)

  • 김재식;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1077-1079
    • /
    • 2000
  • In this paper. the design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form. the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it can be verified how much the voltage distortion is effected when the nonlinear load is connected.

  • PDF

제어기 성능을 고려한 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller)

  • 민완기;김재식;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.206-211
    • /
    • 2005
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

  • PDF