• Title/Summary/Keyword: consistency tests

Search Result 199, Processing Time 0.021 seconds

BDM Rolling of Middle Sized H-beams from a Bloom (블룸을 이용한 중형 H 형강 BDM 압연 공정 연구)

  • Kim, J.M.;Kim, K.W.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • H-beams are generally produced by hot rolling composed of a Break Down Mill (BDM) and a Finishing Mill (FM). The goal of the current study was to develop BDM rolling of H300x300 beams from blooms slit from slabs. In order to manufacture H300x300 beams, the caliber design and the pass schedule of BDM rolling were proposed for a bloom instead of a beam blank. The proposed BDM caliber design and pass schedule were tested using FE-simulation and pilot tests. For the major shape dimensions, such as flange width, web height, web thickness, as well as BDM rolling loads, a comparative analysis between the FE-simulation and the pilot rolling tests was conducted. The results of FEM analysis and pilot rolling tests showed good consistency. Moreover, BDM rolling loads were predicted to be in the range of allowable rolling loads. It was concluded that the designed BDM rolling is suitable for implementation within current manufacturing capacity.

Development of the Korean Handwriting Assessment for Children Using Digital Image Processing

  • Lee, Cho Hee;Kim, Eun Bin;Lee, Onseok;Kim, Eun Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4241-4254
    • /
    • 2019
  • The efficiency and accuracy of handwriting measurement could be improved by adopting digital image processing. This study developed a computer-based Korean Handwriting Assessment tool. Second graders participated in this study by performing writing tasks of consonants, vowels, words, and sentences. We extracted boundary parameters for each letter using digital image processing and calculated the variables of size, size coefficient of variation (CV), misalignment, inter-letter space, inter-word space, and ratio of inter-letter space to inter-word space. Children were also administered traditional handwriting and visuomotor tests. Digital variables from image processing were correlated with these previous tests. Using these correlations, we established a three-point scoring system that computed test scores for each variable. We analyzed inter-rater reliability between the computer rater and human rater and test-retest reliability between the first and second performances. The validity was examined by analyzing the relationship between the Korean Handwriting Assessment and previous handwriting and visuomotor tests. We suggested the Korean Handwriting Assessment to measure size, size consistency, misalignment, inter-letter space, inter-word space, and space ratio using digital image processing. This Korean Handwriting Assessment tool proved to have reliability and validity. It is expected to be useful for assessing children's handwriting.

Verification of OpenMC for fast reactor physics analysis with China experimental fast reactor start-up tests

  • Guo, Hui;Huo, Xingkai;Feng, Kuaiyuan;Gu, Hanyang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3897-3908
    • /
    • 2022
  • High-fidelity nuclear data libraries and neutronics simulation tools are essential for the development of fast reactors. The IAEA coordinated research project on "Neutronics Benchmark of CEFR Start-Up Tests" offers valuable data for the qualification of nuclear data libraries and neutronics codes. This paper focuses on the verification and validation of the CEFR start-up modelling using OpenMC Monte-Carlo code against the experimental measurements. The OpenMC simulation results agree well with the measurements in criticality, control rod worth, sodium void reactivity, temperature reactivity, subassembly swap reactivity, and reaction distribution. In feedback coefficient evaluations, an additional state method shows high consistency with lower uncertainty. Among 122 relative errors in the benchmark of the distribution of nuclear reaction, 104 errors are less than 10% and 84 errors are less than 5%. The results demonstrate the high reliability of OpenMC for its application in fast reactor simulations. In the companion paper, the influence of cross-section libraries is investigated using neutronics modelling in this paper.

Psychometric Properties of the Alzheimer's Disease Knowledge Scale-Korean Version (한국어판 알츠하이머병 지식 측정도구의 신뢰도와 타당도)

  • Kim, Eun Joo;Jung, Ji-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.1
    • /
    • pp.107-117
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the psychometric properties of the Korean version of the Alzheimer's Disease Knowledge Scale (ADKS-K) to determine its applicability to Korean adults. Methods: Cross-cultural validity was performed according to Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN). The Kuder-Richardson Formula 20 for internal consistency and Intraclass Correlation Coefficient (ICC) for test-retest reliability were conducted. Content validity, criterion related validity and construct validity were evaluated. The Classical Test Theory (CTT) model and the Item Response Theory (IRT) model were applied in performing the item analysis. Results: The KR 20 was .71, and the ICC was .90, indicating that the ADKS-K has internal consistency and stability reliability. Thirty items of the ADKS-K had significant Content Validity Ratio (CVR) values, i.e., mean of 0.82 and range of 0.60~1.00. Mean item difficulty and discrimination indices calculated by TestAn program were 0.63 and 0.23, respectively. Mean item difficulty and discrimination indices calculated by BayesiAn program were -0.60 and 0.77, respectively. These tests indicate that ADKS-K has an acceptable level of difficulty and discriminating efficiency. Conclusion: Results suggest that ADKS-K has the potential to be a proper instrument for assessing AD knowledge in Korean adults.

Reliability and Validity of the Korean Translation of the Pediatric Evaluation of Disability Inventory in School-Aged Children With Cerebral Palsy

  • Kim, Won-Ho;Park, Eun-Young;Park, So-Yeon
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.69-76
    • /
    • 2010
  • The purposes of this study were to examine the reliability and validity of Korean translation of Pediatric Evaluation of Disability Inventory (PEDI-K) in school-aged children with cerebral palsy (CP). The PEDI-K, Functional Independence Measure for Children (WeeFIM) and Gross Motor Function Classification System (GMIFCS) were completed in 104 school-aged children with CP by therapists. The internal consistency of the PEDI-K was calculated by Cronbach's alpha (${\alpha}$) for assessing reliability. Concurrent validity was evaluated by correlation with the subsets of WeeFIM. Discriminant validity was assessed by comparing GMFCS levels with tests of the PEDI-K. The results showed that internal consistency was good (Cronbach's ${\alpha}$ ranged from .97~.98). Concurrent validity was demonstrated. The correlation with WeeFIM was high in the Functional Skills (self-care, r=.74~.94; mobility, r=.59~.91; social function, r=.65~.93) and in the Caregiver Assistance (self-care, r=.75~.94; mobility, r=.63~.90; social function, r=.78~.96). Discriminant validity was demonstrated on significant decreases in domain scores with increasing GMFCS levels. Reliability and validity have been demonstrated on the PEDI-K. This study extends usage of PEDI-K in clinical activities and research.

ACTIVE FAULT-TOLERANT CONTROL OF INDUCTION MOTOR DRIVES IN EV AND HEV AGAINST SENSOR FAILURES USING A FUZZY DECISION SYSTEM

  • Benbouzid, M.E.H.;Diallo, D.;Zeraoulia, M.;Zidani, F.
    • International Journal of Automotive Technology
    • /
    • v.7 no.6
    • /
    • pp.729-739
    • /
    • 2006
  • This paper describes an active fault-tolerant control system for an induction motor drive that propels an Electrical Vehicle(EV) or a Hybrid one(HEV). The proposed system adaptively reorganizes itself in the event of sensor loss or sensor recovery to sustain the best control performance given the complement of remaining sensors. Moreover, the developed system takes into account the controller transition smoothness in terms of speed and torque transients. In this paper which is the sequel of (Diallo et al., 2004), we propose to introduce more advanced and intelligent control techniques to improve the global performance of the fault-tolerant drive for automotive applications(e.g. EVs or HEVs). In fact, two control techniques are chosen to illustrate the consistency of the proposed approach: sliding mode for encoder-based control; and fuzzy logics for sensorless control. Moreover, the system control reorganization is now managed by a fuzzy decision system to improve the transitions smoothness. Simulations tests, in terms of speed and torque responses, have been carried out on a 4-kW induction motor drive to evaluate the consistency and the performance of the proposed fault-tolerant control approach.

Study on the Evaluation of Stability of Gel Structured Cosmetics

  • Park, Chan-Ik;Kim, Ki-Sun;Lee, Sung-Jun;Yoon, Myeong-Suk;Kang, Seh-Hoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.2
    • /
    • pp.167-173
    • /
    • 1996
  • The stability of gel structured emulsion and the effect of polyols on it have been studied by rheological property and interfacial tension. In this paper, three types of gel structured emulsions were prepared by using three polyols respectively(glycerine for sample 1, 1.3 BG for sample 2, PG for sample 3). And both complex modulus($G^*$) and loss angle[$\delta$ = tan-1(G"/G')] of samples were investigated against oscillating shear stress and frequency($\omega$). The results show sample 1 is most highly consistent with oscillating shear stress. And the results were compared with those of accelerated tests concerning storage stability of gel structured emulsion. To correlate consistency of rheological property with storage stability, interfacial tension from which adsorption efficiency of surfactant(Octyldodecyl Ether) could be known was measured. Sample 1 showed the largest value of [$d{\gamma}/dIn_{Cconc. of surfactant}$] in Gibbs equation. In summary, the prediction of stability could be correctly made by the consistency of rheological property(G*,$\gamma$) of gel structured emulsion against oscillating shear stress and it could be supported by measuring interfacial tension. And polyol affected the value of [$d{\gamma}/dIn_{Cconc. of surfactant}$], consequently affected the stability.lity.

  • PDF

Quality Characteristics of Tomato Sauce Prepared by Addition of Fresh Basil (Basil의 첨가량을 달리한 Tomato Sauce의 품질 특성)

  • Yoo, Seung-Seok;Kim, Jang-Ho
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.17 no.6
    • /
    • pp.876-882
    • /
    • 2007
  • The purpose of this study was to investigate the effects of basil on the quality characteristics of tomato sauce, which is used widely in Western cuisine. The highest pH of 4.29 was observed in the tomato sauce with 4% fresh basil added, while the tomato sauce with 0% fresh basil exhibited the lowest pH of 4.20. The pH of the tomato sauce gradually increased with the addition of fresh basil. The analysis of color differences in the tomato sauce indicated that redness(avalue) decreased with the addition of basil;, whereas consistency and spreadability increased with the increasing amounts of the fresh basil. The sensory evaluation was performed with scoring tests for color, flavor, taste, after taste, viscosity, and overall acceptability by 15 professional panelsists. The tomato sauce with 2% basil showed the best score in the sensory evaluation, except for vicosity. From the above results, the data suggest that an addition of 2% fresh basil to tomato sauce is recommended for commercial use.

  • PDF

Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers (방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단)

  • Seung-Chul Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

Evaluation of Chemical Durability of Vitrified Forms for Simulated Radioactive Waste Using Product Consistency Test(PCT) and Vapor Hydration Test(VHT) (Product Consistency Test(PCT)와 Vapor Hydration Test(VHT)를 이용한 모의 방사성폐기물 유리고화체의 화학적 내구성 평가)

  • Kim Cheon-Woo;Kim Ji-Yean;Maeng Sung-Jun;Park Jong-Kil;Hwang Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.227-234
    • /
    • 2006
  • Two candidate glasses, AG8W1 and DG-2, have been developed for vitrifying the mixture of low activity resin, zeolite and Dry Active Waste(DAW), and DAW solely, respectively. In order to evaluate the chemical durability of the glasses, two different leaching tests, Product Consistency Test(PCT) and Vapor Hydration Test(VHT), have been performed. As the results of PCT performed from 7 to 120 days, the leach rates of B, Na, Si and Li in the glasses were much lower than those of the benchmark glass(SRL-EA). As the result of VHT peformed for 7 days, the leach rates were 2 and $10g/m^2/day$ for AG8W1 and DG-2, respectively, The results of VHT met the regulatory guideline( $<50g/m^2/day$) for the low activity glasses of Hanford in the USA. Consequently, two candidate glasses to be used at a commercial operation in the future showed that their chemical durability is satisfactory according to the results of two leaching tests.

  • PDF