• Title/Summary/Keyword: connection detailing

Search Result 25, Processing Time 0.027 seconds

Experimental Evalutation of the Seismic Performance of WUF-W Moment Connections with a Modified Access Hole (개선된 엑세스 홀 형상을 갖는 WUF-W접합부의 실험을 통한 내진성능평가)

  • Han, Sang Whan;Jung, Jin;Moon, Ki-Hoon;Kim, Jin Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.21-28
    • /
    • 2012
  • Welded Unreinforced Flange-Welded Web (WUF-W) connection is one of Special Moment Frame (SMF) specified in ANSI/AISC-358. From the experimental test of WUF-W connection specimens conducted by the previous study, fracture occurred in the beam flange before achieving total inter-story drift angle of 0.04radian required for Special Moment Frames (SMF) system even though the specimens satisfied the design and detailing requirement specified in ANSI/AISC-358. These results are estimated as problem of the access hole geometry. In this study, a full-scale WUF-W connection specimen was made with a modified access hole geometry, and tested with the same test setting and loading as the previous test. From test results, the deformation capacity of the tested WUF-W connection specimen exceeded 4%, which is required for connections in SMF system. Comparing with the WUF-W specimens of the previous study, the strain demand of the beam flange in the tested specimen was decreased and energy dissipation capacity of the specimen was improved.

A Study on Shear Connector Performance Estimation for Plan Extension of RC Apartment Structures (철근콘크리트 공동주택의 평면확장을 위한 연결부의 전단성능 평가에 관한 연구)

  • Kim, Dong Baek
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.27-34
    • /
    • 2015
  • Nowadays, remodeling cases for some apartment like Hyundai through the support of government are reported. Conventionally, balcony and aisle are extended for additional private area or balcony which is supported by new frame is extended. In extension work at site, dowel bar is conventionally inserted in old concrete slab for connection with old and new slab, however, an examination for structural safety is rarely performed prior to construction, if ever, vertical load is only considered for structural analysis. When conventionally connected structures are exposed to earthquake, the old and new structures have individual earthquake behavior with different mode, which may lead the elimination of resistance to earthquake in new structures. As of this reason, new detailing connection system which can have light weight and sufficient ductility performance is developed for application to domestic extension works. Additionally, user manual and specification are also developed for fertilization of application for the developed technology.

Study of exterior beam-column joint with different joint core and anchorage details under reversal loading

  • Rajagopal, S.;Prabavathy, S.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.6
    • /
    • pp.809-825
    • /
    • 2013
  • In the present study, in reinforced concrete structures, beam-column connections are one of the most critical regions in areas with seismic susceptibility. Proper anchorage of reinforcement is vital to enhance the performance of beam-column joints. Congestion of reinforcement and construction difficulties are reported frequently while using conventional reinforcement detailing in beam-column joints of reinforced concrete structures. An effort has been made to study and evaluate the performance of beam-column joints with joint detailing as per ACI-352 (mechanical anchorage), ACI-318 (conventional hooks bent) and IS-456(full anchorage conventional hooks bent) along with confinement as per IS-13920 and without confinement. Apart from finding solutions for these problems, significant improvements in seismic performance, ductility and strength were observed while using mechanical anchorage in combination with X-cross bars for less seismic prone areas and X-cross bar plus hair clip joint reinforcement for higher seismic prone areas. To evaluate the performances of these types of anchorages and joint details, the specimens were assembled into four groups, each group having three specimens have been tested under reversal loading and the results are presented in this paper.

Rehabilitation of exterior RC beam-column connections using epoxy resin injection and galvanized steel wire mesh

  • Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • v.16 no.3
    • /
    • pp.253-263
    • /
    • 2019
  • The efficacy of a galvanized steel wire mesh (GSWM) as an alternative material for the rehabilitation of RC beam-column connections damaged due to reversed cyclic loading was investigated. The repair mainly uses epoxy resin infused under pressure into the damaged zone and then confined using three types of locally available GSWM mesh. The mesh types used herein are (a) Weave type square mesh with 2mm grid opening (GWSM-1) (b) Twisted wire mesh with hexagonal opening of 15 mm (GSWM-2) and (c) welded wire mesh with square opening of 25 mm (GSWM-3). A reduced scale RC beam-column connection detailed as per ductile detailing codes of Indian Standard was considered for the experimental investigation. The rehabilitated specimens were also subjected to similar cyclic displacement. Important parameters related to seismic capacity such as strength, stiffness degradation, energy dissipation, and ductility were evaluated. The rehabilitated connections exhibited equal or better performance and hence the adopted rehabilitation strategies could be considered as satisfactory. Confinement of damaged region using GSWM-1 significantly enhanced the seismic capacity of the connections.

Seismic Performance of Circular RC Bridge Columns with Longitudinal Steel Connection Details (축방향철근 연결상세에 따른 철근콘크리트 원형교각의 내진성능)

  • Lee Jae-Hoon;Son Hyeok-Soo;Ko Seong-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.249-260
    • /
    • 2004
  • The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable, however the current Korean bridge design specifications have no special provisions about lap-splices of longitudinal steel. This paper reports experimental results of a research program investigating the seismic performance of circular RC bridge columns with respect to longitudinal steel connection detailing. Twenty-one circular column specimens were tested under quasi-static test. The columns with the entire longitudinal steel lap-spliced within plastic hinge region show relatively sudden strength degradation and low ductility than the columns with continuous longitudinal steel and the columns with half of longitudinal steel lap-spliced. However, the seismic performance of the column with mechanically connected longitudinal steel is similar to that of the column with continuous longitudinal steel. The final objectives of this study are to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and to provide quantitative reference data and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, collapse, etc. Ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio, residual deformation index, and effective stiffness are investigated and discussed in this paper.

Experimental Study on Seismic Performance of Beam-column Connections with High Strength Reinforcements (고장력 철근이 적용된 철근콘크리트 보-기둥 접합부 파괴모드에 대한 실험적 연구)

  • Kim, Dae-Hoon;Park, Aa-Ron;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.61-68
    • /
    • 2016
  • Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix II. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.

A Study on Trompe l′Oeil Expressed in Modern Fashion -Focused on 1990s- (현대 패션에 표현된 Trompe l′Oeil 기법 연구 -1990년대를 중심으로-)

  • 조진숙
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.5
    • /
    • pp.880-896
    • /
    • 2004
  • Trompe l'Oeil technique strategically conceived with a view to effectively realize creative ideas among the expression techniques of fine arts style has provided the driving force in development of fine arts and has continuously influenced development of the modem fashion pursuing unique individuality. The study is focused first on finding out how Trompe l'Oeil technique originated in connection with researching the fashion of Trompe l'Oeil and on analysing the technique of expression. The author referred to fashion magazines for designing ideas of Trompe l'Oeil represented in modem fashion in practical applications used by designers in Paris, Italy, London and New York during the 10 year period(1990-1999). The collections of data were analyzed as following: Effectiveness depending on the method of Trompe l'Oeil I. Effectiveness of Layering: when two clothing are over lapped or coordinated with one another in color or style. 2. Effectiveness of Detailing: when pictures, stitch, tape, cutting, quilting and etc are used to create collar, pocket, yoke, zipper, string, shadow and etc. 3. Effectiveness of Accessories: when the image of necklace, belt, tie, tassel, badges and stars are represented by illustration or embroidery on clothing to substitute the actual existence. 4. Effectiveness of Nudity: when human body is realistically drawn and printed on clothing.

  • PDF

Seismic Retrofit Design of RHS Column-to-H Beam Connections (RHS 기둥-H형강보 접합부의 내진보강 설계)

  • Kim, Young Ju;Oh, Sang Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.529-537
    • /
    • 2008
  • The objective of this paper is to propose retrofit design methods of theRHS column-to-H beam connections with floor slabs. Referring to previous studies on the retrofitting of moment connections, it is clear that connections retrofitted with a stiffened RBS (SR) or a lengthened horizontal stiffener (LH) has an effect on decreasing the stress/strain concentration. A new design procedure using these two retrofitting methods was thus presented. In addition, this paper addressed various design or detailing options and recommended a procedure for designing the improved retrofitting method of steel moment connections. Finally, a pilot test was conducted to verify the design procedure.

Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections (프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능)

  • Choi, Hyun-Ki;Choi, Yun-Cheul;Choi, Chang-Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.61-71
    • /
    • 2010
  • Five half-scale beam-to-column connections in a precast concrete frame were tested with cyclic loading that simulated earthquake-type motions. Five half -scale interior beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including one monolithic specimen and four precast specimens. Variables included the detailing used at the joint to achieve a structural continuity of the beam reinforcement, and the type of special reinforcement in the connection (whether ECC or transverse reinforcement). The specimen design followed the strong-column-weak-beam concept. The beam reinforcement was purposely designed and detailed to develop plastic hinges at the beam and to impose large inelastic shear force demands into the joint. The joint performance was evaluated on the basis of connection strength, stiffness, energy dissipation, and drift capacity. From the test results, the plastic hinges at the beam controlled the specimen failure. In general, the performance of the beam-to-column connections was satisfactory. The joint strength was 1.15 times of that expected for monolithic reinforced concrete construction. The specimen behavior was ductile due to tensile deformability by ECC and the yielding steel plate, while the strength was nearly constant up to a drift of 3.5 percent.

Analytical Investigation for Improved Design Models of Chevron Braced Frames (역V형 가새 골조의 개선된 디자인 모델을 위한 해석적 연구)

  • Yoo, Jung-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.73-78
    • /
    • 2009
  • Steel Braced frames are a commonly-used seismic resisting system, and chevron steel braced frames are a frequently used type of steel braced frame. Recent research has indicated that the seismic performance of braced frames can be improved by designing the braced frame gusset plate connections in a manner that direct reflects seismic deformation demands, and by permitting yielding in the gusset plate at select performance levels. A parametric study using Finite Element (FE) models was conducted to examine the influence of the gusset plate and framing elements on the seismic performance of chevron braced frames, and to calibrate and develop improved design models. The impact of the frame details, including frame sizes, clearance requirements, gusset plate thickness and tapered plate, was explored. The results suggested that proper detailing of the connection can result in a significant improvement in the frame performance. The results also show that the gusset plate thickness has a significant impact on frame performance.