• 제목/요약/키워드: connection design

검색결과 2,552건 처리시간 0.043초

철근콘크리트 프리캐스트 대형판 접합부의 설계 및 해석 (Design and Analysis on The Connections of RC Precast Large Panel)

  • 박강근
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.85-92
    • /
    • 2006
  • 본 연구에서는 철근콘크리트 프리캐스트 대형판의 접합부 설계방법 및 해석방법에 대해서 연구를 수행하였다. 접합부의 설계방법은 수평접합부와 수직접합부의 구조적 거동에 대한 안정성 및 일체성을 확보하기 위한 설계법을 제시하였고, 접합부의 해석은 강체스프링 모델에 의한 탄소성해석을 수행 하였다.

  • PDF

증폭모듈을 이용한 마이크로파 다단증폭기 설계시 최적의 모듈간 연결길이 결정 (Determination of the optimum connection length between modules in the design of microwave multistage amplifiers using amplifier modules)

  • 임종식;강성춘
    • 전자공학회논문지D
    • /
    • 제34D권3호
    • /
    • pp.25-33
    • /
    • 1997
  • In the design of microwave multi-stage amplifiers composed of N amplifier modules, the variation of performances of amplifier as various connection length between modules has been studied. In addition, the methods, equations and conditions for the maximum gain or the most flat gain are presented. The results of sensitivity analysis for the connection length showed that the small change in phase of input, output reflection coefficients(S$_{11}$, S$_{22}$) of module itself is the most important in determination of connection length for the most flat gain. Th egain flatness of 2-module amplifier of which connection length between modules had been determined by presented methods was the best one out of performances with various arbitrary connectio lengths.s.

  • PDF

Bolted end plate connections for steel reinforced concrete composite structures

  • Li, Xian;Wu, Yuntian;Mao, Weifeng;Xiao, Yan;Anderson, J.C.;Guo, Yurong
    • Structural Engineering and Mechanics
    • /
    • 제24권3호
    • /
    • pp.291-306
    • /
    • 2006
  • In order to improve the constructability and meanwhile ensure excellent seismic behavior, several innovative composite connection details were conceived and studied by the authors. This paper reports experimental results and observations on seismic behavior of steel beam bolted to reinforced concrete column connections (bolted RCS or BRCS). The proposed composite connection details involve post tensioning the end plates of the steel beams to the reinforced concrete or precast concrete columns using high-strength steel rods. A rational design procedure was proposed to assure a ductile behavior of the composite structure. Strut-and-tie model analysis indicates that a bolted composite connection has a favorable stress transfer mechanism. The excellent capacity and behavior were then validated through five full-scale beam to column connection model tests.

휴먼 에러 방지용 배선 안내 시스템 개발 (A Human Error-Free Wiring Guide System)

  • 이현찬;김주한;김진성;정연욱
    • 한국CDE학회논문집
    • /
    • 제22권2호
    • /
    • pp.181-189
    • /
    • 2017
  • In this paper, we develop a human error-free wire connection guide system. The only related work is Japanese patent by Hitachi. The patent is guiding the wire connection using PC server. And no implementation details have been reported publicly. We propose a new method based on smart mobile devices. The proposed methods are registered as two Korean patents. We implement a prototype wire connection guide system to verify the patents. Through human experiments, we verify the system can reduce the human error more than 90% and speed up the connection process more than twice faster than working without the system. To be used in the industrial fields, the prototype system needs more product packaging works.

다중접속 CFL용 PFC 및 THD 감소 시스템의 설계 및 구현 (Design and Implementation of PFC and THD Reduction System for CFL Mulitple Connection)

  • 박종연;조호찬;최원호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.67-70
    • /
    • 2002
  • In this paper, we have researched a Automatic Power Factor Correction and THD reduction System for the multiple connection of CFL. Also in this paper, the power factor has been researched for the design of CFL, found the reason why the power factor is low and THD is too high. This paper has designed the PFC System for the multiple connection of CFL, and then we have increased the power factor and reduced the total harmonic distortion, by implementing them.

  • PDF

An improved polynomial model for top -and seat- angle connection

  • Prabha, P.;Marimuthu, V.;Jayachandran, S. Arul;Seetharaman, S.;Raman, N.
    • Steel and Composite Structures
    • /
    • 제8권5호
    • /
    • pp.403-421
    • /
    • 2008
  • The design provisions for semi-rigid steel frames have been incorporated in codes of practice for steel structures. In order to do the same, it is necessary to know the experimental moment-relative rotation (M-${\theta}_r$) behaviour of beam-to-column connections. In spite of numerous publications and collection of several connection databases, there is no unified approach for the semi-rigid design of steel frames. Amongst the many connection models available, the Frye-Morris polynomial model, with its limitations reported in the literature, is simple to adopt at least for the linear design space. However this model requires more number of connection tests and regression analyses to make it a realistic prediction model. In this paper, 3D nonlinear finite element (FE) analysis of beam-column connection specimens, carried out using ABAQUS software, for evaluating the M-${\theta}_r$ behaviour of semi-rigid top and seat-angle (TSA) bolted connections are described. The finite element model is validated against experimental behaviour of the same connection with regard to their moment-rotation behaviour, stress distribution and mode of failure of the connections. The calibrated FE model is used to evaluate the performance of the Frye-Morris polynomial model. The results of the numerical parametric studies carried out using the validated FE model have been used in proposing modifications to the Frye-Morris model for TSA connection in terms of the powers of the size parameters.

Experimental study on through-beam connection system for concrete filled steel tube column-RC beam

  • Tian, Chunyu;Xiao, Congzhen;Chen, Tao;Fu, Xueyi
    • Steel and Composite Structures
    • /
    • 제16권2호
    • /
    • pp.187-201
    • /
    • 2014
  • A new through-beam connection system for a concrete filled steel tube column to RC beam is proposed. In this connection, there are openings on the steel tube while the reinforced concrete beams are continuous in the joint zone. The moment and shear force at the beam ends can be transferred to column by continuous rebar and concrete. The weakening of the axial load and shear bearing capacity due to the opening of the steel tube can be compensated by strengthening steel tube at joint zone. Using this connection, construction of the joint can be made more convenient since welding and hole drilling in situ can be avoided. Axial compression and reversed cyclic loading tests on specimens were carried out to evaluate performance of the new beam-column connection. Load-deflection performance, typical failure modes, stress and strain distributions, and the energy dissipation capacity were obtained. The experimental results showed that the new connection have good bearing capacity, superior ductility and energy dissipation capacity by effectively strengthen the steel tube at joint zone. According to the test and analysis results, some suggestions were proposed to design method of this new connection.

Mechanical performance of a new I-section weak-axis column bending connection

  • Lu, Linfeng;Xu, Yinglu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제26권1호
    • /
    • pp.31-44
    • /
    • 2018
  • This paper reports a novel steel beam-to-column connection suitable for use in the weak axis of I-section column. Monotonic and cyclic loading experimental investigations and numerical analysis of the proposed weak-axis connection were conducted, and the calculation procedure of the beam-column relative rotation angle and plastic rotation angle was developed and described in details. A comparative analysis of mechanical property and steel consumption were employed for the proposed I-section column weak-axis connection and box-section column bending connection. The result showed that no signs of fracturing were observed and the plastic hinge formed reliably in the beam section away from the skin plate under the beam end monotonic loading, and the plastic hinge formed much closer to the skin plate under the beam end cyclic loading. The fracture of welds between diaphragm and skin plate would cause an unstable hysteretic response under the column top horizontal cyclic loading. The proposed weak-axis connection system could not only simplify the design calculation progress when I-section column is adopted in frame structural design but also effectively satisfy the requirements of 'strong joint and weak member', as well as lower steel consumption.

강구조에서 ㄱ형강을 이용한 반강접 접합의 간편 설계 (A Study on the Simple Design Method of Semi-Rigid Connection with Angle in Steel Structure)

  • 허명재;김홍근;최원구
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.261-273
    • /
    • 2011
  • 최근에는 건축물의 대형화, 고층화라는 시대적인 흐름과 요구로 인해서 철골 구조의 수요가 급증하고 있다. 일반적인 철골 구조의 해석은 접합부를 강접합과 단순접합으로 가정하여 수행되고 있는데, 강접합(Fixed connection)의 경우에는 절점에 연결된 각 부재의 변형 전 상대적인 각도가 변형 후에도 그대로 유지된다고 가정하므로 접합부가 충분한 강성을 발휘하고 안정성을 확보하도록 패널존 부분에 스티프너로 보강을 한다. 하지만 인건비 상승과 함께 강접 접합부의 제작비가 과도해짐으로 경제성 측면에서 스티프너 보강을 생략한 접합부의 필요성이 증가하고 있다. 반면, 단순접합(Pinned connection)의 경우에는 단순보처럼 거동하여 보와 기둥 사이에 휨모멘트가 전달되지 않는다고 가정한다. 이는 공장제작이 간단하고, 시공이 간편한 장점이 있으나 접합부에서 모멘트를 전달할 수 없어서 구조적인 효율이 떨어지는 단점이 있다. 반강접의 도입은 단면치수 결정의 효율성을 증대하고, 현장에서의 부재조립 용이성, 골조 전체의 안전성 확보 등의 이점이 있어서 외국의 경우, 보-기둥 접합부의 실제적인 거동을 파악하기 위해서 계속적인 노력을 해왔고 그 결과를 규준에 적용하고 있다. 본 논문은 미국 AISC의 LRFD 설계규준을 참고하여 국내 강재를 적용한 반강접의 구조해석을 실시해서 각 강재에 대한 자료은행을 만들 것이고 이상화된 접합부의 구조해석 결과와 비교하여 경제성 측면, 단부 고정계수, 회전강성과 함께 반강접을 고려한 구조물의 설계 방안을 제시 하고자 한다.

DDM Rotordynamic Design Sensitivity Analysis of an APU Turbogenerator Having a Spline Shaft Connection

  • Lee, An-Sung;Ha, Jin-Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.57-63
    • /
    • 2003
  • An eigenvalue design sensitivity formulation of a general nonsymmetric-matrix rotor-bearing system is devised. using the DDM (direct differential method). Then, investigations on the design sensitivities of critical speeds are carried out for an APU turbogenerator with a spline shaft connection. Results show that the dependence of the rate of change of the critical speed on the stiffness changes of bearing models of spline shaft connection points is negligible, and thereby their modeling uncertainty does not present any problem. And the passing critical speeds up to the 4th critical speed are not sensitive to the design stiffness coefficients of four main bearings. Further, the dependence of the rate of change of the critical speed on the shaft-element length changes shows quantitatively that the spline shaft has some limited influence on the 4th critical speed but no influence on the 1st to 3rd critical speeds. With no adverse effect from the spline shaft, the APU system achieves a critical speed separation margin of more than 40% at a rated speed of 60,000 rpm.