• Title/Summary/Keyword: connection between the operations

Search Result 83, Processing Time 0.033 seconds

Grid-Connected Dual Stator-Winding Induction Generator Wind Power System for Wide Wind Speed Ranges

  • Shi, Kai;Xu, Peifeng;Wan, Zengqiang;Bu, Feifei;Fang, Zhiming;Liu, Rongke;Zhao, Dean
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1455-1468
    • /
    • 2016
  • This paper presents a grid-connected dual stator-winding induction generator (DWIG) wind power system suitable for wide wind speed ranges. The parallel connection via a unidirectional diode between dc buses of both stator-winding sides is employed in this DWIG system, which can output a high dc voltage over wide wind speed ranges. Grid-connected inverters (GCIs) do not require booster converters; hence, the efficiency of wind energy utilization increases, and the hardware topology and control strategy of GCIs are simplified. In view of the particularities of the parallel topology and the adopted generator control strategy, we propose a novel excitation-capacitor optimization solution to reduce the volume and weight of the static excitation controller. When this excitation-capacitor optimization is carried out, the maximum power tracking problem is also considered. All the problems are resolved with the combined control of the DWIG and GCI. Experimental results on the platform of a 37 kW/600 V prototype show that the proposed DWIG wind power system can output a constant dc voltage over wide rotor speed ranges for grid-connected operations and that the proposed excitation optimization scheme is effective.

Modified Fontan Procedure for Single or Dominant Right Ventricle (우세우심실 또는 우단심실증에서의 변형 Fontan 수술)

  • 백완기
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.310-321
    • /
    • 1991
  • Between April 1986 and September 1990, 34 patients with a single or dominant right ventricle underwent modified Fontan procedure for definite palliation in Seoul National University Children`s Hospital. Their age at operation ranged from 8 months to 14 years [Mean 5.5 years]. The ventricular chamber was solitary and of indeterminate trabecular pattern in 6 patients. 28 patients had posteriorly located rudimentary chamber, all of which were trabecular pouches having no communication with outlet septum. The patterns of atrioventricular connection were common inlet[9], double inlet [11], left atrioventricular valve atresia [12] and right atrioventricular valve atresia with L-loop [2]. Pulmonary outflow tracts were atretic in 7 patients and stenotic in 26 patients. Major associated anomalies included anomalous systemic venous drainage [15], dextrocardia [12] and total anomalous pulmonary venous connection[3]. Shunt operations were previously performed in 13 patients and pulmonary artery banding and atrial septectomy in 1 patients. Surgery included intraatrial baffling in 26 patients, bidirectional cavopulmonary shunt in 13 patients, atrioventricular valve obliteration in 3 patients and atrioventricular valve replacement in 3 patients. Central venous pressure measured postoperatively at intensive care unit ranged from 18cm H2O to 28cm H2O [mean 23.2cm H2O]. Hospital mortality was 35.3% [12/34], all died out of low output syndrome. Suspected causes of low output syndrome include ventricular dysfunction [8], hypoplastic or tortuous pulmonary artery [2] and elevated pulmonary vascular resistance [2]. 19 patients had 31 major complications including low output syndrome [18], arrhythmia [4], acute renal failure [3] and respiratory failure [3]. Mortality rate was significantly higher in the groups receiving intraatrial baffling and AV valve replacement respectively [p<0.05]. 20 patients were followed up postoperatively with the mean follow-up period 15.0$\pm$11.6 months. There were no late death and follow-up catheterization was performed in 10 patients. Mean right atrial pressure was 15.4$\pm$6.8mmHg and ventricular contraction was reasonable in all but one case. Thus, Fontan principle can be applied successfully to all the patients with complex cardiac anomaly of single ventricle variety and better results can be anticipated with judicious selection of patient and improvement of postoperative care.

  • PDF

물리적 통신망의 이중연결성을 위한 확장 문제에 관한 연구

  • 이희상;안광모
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.83-86
    • /
    • 1996
  • In this paper we study the problem of augmenting a physical network to improve the topology for new survivable network architectures. We are given a graph G=(V,E,F), where V is a set of nodes that represents transmission systems which be interconnected by physical links, and E is a collection of edges that represent the possible pairs of nodes between which a direct transmission link can be placed. F, a subset of E is defined as a set of the existing direct links, and E/F is defined as a set of edges for the possible new connection. The cost of establishing network $N_{H}$=(V,H,F) is defined by the sum of the costs of the individual links contained in new link set H. We call that $N_{H}$=(V,H,F) is feasible if certain connectivity constrints can be satisfied in $N_{H}$=(V,H,F). The computational goal for the suggested model is to find a minimum cost network among the feasible solutions. For a k edge (node) connected component S .subeq. F, we charactrize some optimality conditions with respect to S. By this characterization we can find part of the network that formed by only F-edges. We do not need to augment E/F edges for these components in an optimal solution. Hence we shrink the related component into a node. We study some good primal heuristics by considering construction and exchange ideas. For the construction heuristics, we use some greedy methods and relaxation methods. For the improvement heuristics we generalize known exchange heuristics such as two-optimal cycle, three-optimal cycle, pretzel, quezel and one-optimal heuristics. Some computational experiments show that our heuristic is more efficient than some well known heuristics.stics.

  • PDF

A Secure Yoking-Proof Protocol Providing Offline Verification (오프라인 검증을 지원하는 안전한 요킹증명 프로토콜)

  • Ham, Hyoungmin
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.113-120
    • /
    • 2021
  • RFID (Radio Frequency Identification) yoking authentication provides methods scanning a pair of RFID tags with a reader device and verifying them to ensure the physical proximity of objects. In the first yoking proof protocols, a verifier connected to a reader device online is essential to verify the yoking proof, and this condition limits the environment in which yoking proof can be applied. To solve this limitation, several studies have been conducted on offline yoking proof protocol that does not require the online connection between a reader and a verifier. However, the offline yoking proof protocols do not guarantee the basic requirements of yoking proof, and require relatively more operations on the tag compared to the previous yoking proof protocols. This paper proposes an efficient offline yoking proof protocol that supports offline verification without the need for an online verifier. The proposed protocol provides a secure yoking proof with fewer number of operations than the existing ones, and it also can be extended to the group proof for more than a pair of tags without additional devices. The analysis in this paper shows that the proposed protocol provides offline verification securely and effectively.

Methodology for Computer Security Incident Response Teams into IoT Strategy

  • Bernal, Alejandro Enciso;Monterrubio, Sergio Mauricio Martinez;Fuente, Javier Parra;Crespo, Ruben Gonzalez;Verdu, Elena
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.5
    • /
    • pp.1909-1928
    • /
    • 2021
  • At present, the Colombian government shares information on threats or vulnerabilities in the area of cybersecurity and cyberdefense, from other government agencies or departments, on an ad-hoc basis but not in real time, with the surveillance entities of the Government of the Republic of Colombia such as the Joint Command of Cybernetic Operations (CCOCI) and the Cybernetic Emergencies Response Team of Colombia (ColCERT). This research presents the MS-CSIRT (Management System Computer Security Incident Response Teams) methodology, that is used to unify the guidelines of a CSIRT towards a joint communication command in cybersecurity for the surveillance of Information Technology (IT), Technological Operations (TO), Internet Connection Sharing (ICS) or Internet of Things (IoT) infrastructures. This methodology evaluates the level of maturity, by means of a roadmap, to establish a CSIRT as a reference framework for government entities and as a guide for the areas of information security, IT and TO to strengthen the growth of the industry 4.0. This allows the organizations to draw a line of cybersecurity policy with scope, objectives, controls, metrics, procedures and use cases for the correct coordination between ColCERT and CCOCI, as support entities in cybersecurity, and the different companies (ICS, IoT, gas and energy, mining, maritime, agro-industrial, among others) or government agencies that use this methodology.

A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan (회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화)

  • 이재관;홍성의
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.1
    • /
    • pp.117-117
    • /
    • 1992
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.

Hard rock TBM project in Eastern Korea

  • Jee, Warren W.
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.10a
    • /
    • pp.33-41
    • /
    • 2008
  • The longest tunnel has been halted at Daekwanryung by the failure of the host country of the Winter Olympiad in 2014, but modern High-Power TBM will come to Korea to excavate these long tunnels to establish the better horizontal connection between the western and eastern countries to improve the strong powerful logistic strategy of Korean peninsula. Train operation provides a key function of air movements in a long underground tunnel, and heat generation from transit vehicles may account of the most heat release to the ventilation and emergency systems. This paper indicates the optimal fire suppress services and safety provision for the long railway tunnel which is designed twin tunnel with length 22km in Gangwon province of Korea. The design of the fire-fighting systems and emergency were prepared by the operation of the famous long-railway tunnels as well as the severe lessons from the real fires in domestic and overseas experiences. Designers should concentrate the optimal solution for passenger's safety at the emergency state when tunnel fires, train crush accidents, derailment, and etc. The optimal fire-extinguishing facilities for long railway tunnels are presented for better safety of the comfortable operation in this hard rock tunnel of eastern mountains side of Korea. Since year 1900, hard rock tunnel construction has been launched for railway tunnels in Korea, tunnels have been built for various purposes not only for infrastructure tunnels including roadway, railway, subway, and but also for water and power supply, for deposit food, waste, and oils etc. Most favorable railway tunnel system was discussed in details; twin tunnels, distance of cross passage, ventilation systems, for the comfortable train operations in the future.

  • PDF

Design of a control scheme for applying DC power sources to a distribution system (배전시스템에 DC 전력원을 적용하기 위한 제어 기법 설계)

  • Hwang, Chul-Sang;Kim, Gyeong-Hun;Byeon, Gilsung;Jeon, Jin-Hong;Jo, Chang-Hee;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1056-1057
    • /
    • 2015
  • A common DC bus is a useful connection for several DC output sources such as photovoltaic (PV), fuel cells, and batteries. Operation of the common DC power system with more than two DC output sources, especially in a stand-alone mode, requires a control scheme for the stable operation of the system. In this paper, a control scheme has been developed for applying DC power sources to the distribution system. The purpose of the control scheme is to make the best use of the DC power sources. The DC power system consists of PV, two energy storage systems and a DC-AC inverter with the control scheme. A distribution system was modeled in PSCAD/EMTDC. As the results, the control scheme is applied to the DC-AC inverter and the DC-DC converter for transfer operations between the grid-connected and the stand-alone mode to keep the DC bus and the AC voltage constant. The results from the simulation demonstrate the stable operation of a grid connected DC power system.

  • PDF

Development of a system dynamics computer model to simulate the operational effects of the new environmental technology certification system (환경신기술인증제도의 운영효과를 모의하기 위한 시스템다이내믹스 컴퓨터 모델의 개발)

  • Kim, Taeyoung;Park, Suwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.105-114
    • /
    • 2020
  • In this study, based on the System Dynamics (SD) methodology, the interrelationship between the factors inherent in the operation of the New Technology Certification System (NTCS) in Korea was identified by a causal map containing a feedback loop mechanism in connection with 'new technology development investment', 'commercialization of new technology', and 'sales by new technology'. This conceptualized causal map was applied to the simulation of the operations of the New Excellent Technology and Environmental Technology Verification System (NET&ETV) run by the Ministry of Environment among various NTCSs in Korea. A SD computer simulation model was developed to analyze and predict the operational performance of the NET&ETV in terms of key performance indices such as 'sales by new technology'. Using this model, we predicted the future operational status the NET&ETV and found a policy leverage that greatly influences the operation of the NET&ETV. Also the sensitivity of the key indicators to changes in the external variables in the model was analyzed to find policy leverage.

Strategy for the Seamless Mode Transfer of an Inverter in a Master-Slave Control Independent Microgrid

  • Wang, Yi;Jiang, Hanhong;Xing, Pengxiang
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.251-265
    • /
    • 2018
  • To enable a master-slave control independent microgrid system (MSCIMGS) to supply electricity continuously, the microgrid inverter should perform mode transfer between grid-connected and islanding operations. Transient oscillations should be reduced during transfer to effectively conduct a seamless mode transfer. This study uses a typical MSCIMGS as an example and improves the mode transfer strategy in three aspects: (1) adopts a status-tracking algorithm to improve the switching strategy of the outer loop, (2) uses the voltage magnitude and phase pre-synchronization algorithm to reduce transient shock at the time of grid connection, and (3) applies the hybrid-sensitivity $H_{\infty}$ robust controller instead of the current inner loop to improve the robustness of the controller. Simulations and experiments show that the proposed strategy is more practical than the traditional proportional-derivative control mode transfer and effective in reducing voltage and current oscillations during the transfer period.