• 제목/요약/키워드: cone model

검색결과 371건 처리시간 0.036초

치료계획 시스템을 이용한 Varian Standard Couch 모델링의 유용성 평가 (The evaluation for the usability ofthe Varian Standard Couch modelingusing Treatment Planning System)

  • 양용모;송용민;김진만;최지민;최병기
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.77-86
    • /
    • 2016
  • 목 적 : 방사선 치료 시 Carbon Fiber Couch에 의한 감약이 일어난다. 본 연구에서는 치료계획 시스템(Treatment Planning System: TPS)을 이용해 Varian사의 Varian Standard Couch(VSC)를 모델링 하여 유용성을 평가하고자 한다. 대상 및 방법 : 선형가속기(Clinac IX, VARIAN, USA)의 CBCT(Cone Beam Computed Tomography)를 이용하여 VSC의3가지 조건Side Rail Out Grid(SROG), Side Rail InGrid(SRIG), Side Rail In OutSpine Down Bar(SRIOS)로 스캔 한 후 TPS(Pinnacle9.8, Philips, USA)로 전송하여 Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar를 Automatic Contouring하여 모델링 하였다. 전산화 단층촬영(Light Speed RT 16, GE, USA)으로 스캔 한 Cheese Phantom(Middelton, USA) 을 TPS로 전송하여 모델링 한 VSC를 적용하였다. 측정 점은 Cheese Phantom내의 Ion Chamber(A1SL, Standard imaging, USA)이며 Isocenter에 위치시켜 Energy(4, 10MV), Gantry Angle($5^{\circ}$간격으로 측정), Field Size($3{\times}3cm^2$, $10{\times}10cm^2$)에 변화를 주어 각 100MU의 동일한 조건에서 얻은 계산 값과 측정값을 비교하였으며 Side Bar Upper에 의한 감약을 비교하기 위해 SRIG조건에서 $127^{\circ}$를 포함하였다. 결 과 : CBCT를 이용해 얻은 VSC의 Density를 TPS에서 확인한 결과 $0.9g/cm^3$였으며 Spine Down Bar의 경우 $0.7g/cm^3$로 나타났다.Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar에서 각 17.49%, 16.49%, 8.54%, 7.59%의 감약이 일어났으며모델링의 정확성을 평가하기 위해 계산 값과 측정값을 비교한 결과 평균 1.13%의 오차가 보였으며 Spine Down Bar를 지나는 $170^{\circ}beam$에서 1.98%로 가장 많은오차를 보였다. 결 론 : TPS이용해 모델링 한 VSC의 유용성을 평가하기 위해계산 값과 측정값을 비교한 결과 최대1.98%의 오차를 보였다. 방사선 치료계획 시 VSC를 모델링 하여 적용한다면선량에 대한 예측이 가능해 더욱 정확한 치료를 하는데 도움이 될 것으로 사료된다.

  • PDF

Flupyrazofos(KH-502)의 토양 중 용탈 및 흡착 (Leaching and Adsorption of Flupyrazofos(KH-502) in the Soil)

  • 양재의;조부연;유경렬
    • 한국환경농학회지
    • /
    • 제16권1호
    • /
    • pp.72-79
    • /
    • 1997
  • 신규 활성물질인 Flupyrazofos(KH-502)의 토양에서의 흡착성, 용탈성 및 잔류성을 실내조건과 포장조건하에서 연구하여 본 공시약제의 안전사용을 위한 기초자료를 제공하고 토양-수질환경에 미칠 영향을 예측 평가하기 위한 목적으로 수행한 연구결과는 다음과 같다. 1. Flupyrazofos의 흡착량과 시간과의 사이에는 유의성있는 power function 관계가 있어서, 흡착이 빨리 일어나서 반응 30분 후에 45%가 흡착되고, $6{\sim}12$시간 이후에는 의사(疑似)평형에 도달했다. 2. Flupyrazofos의 흡착은 First-order kinetic model에 유의성있게 따랐고, 가해준 Flupyrazofos의 50%가 흡착되는 시간은 사양토의 경우 5.8시간이었다. 3. Flupyrazofos의 농도에 따른 흡착양상은 Freundlich 등온식으로 설명될 수 있었고, 등온식은 S-형(型)으로 분류될 수 있었다. 4. 토양 column을 통해 용탈된 Flupyrazofos의 농도는 가해준 농도에 비해 매우 낮았다. 용탈된 Flupyrazofos의 농도는 사양토가 식양토보다 약간 높았다. 사양토(砂壤土)에서 용탈된 최대 $C/C_0$ 값이 0.073, 식양토(埴壤土)에서는 0.017에 불과했다. 5. 표토에서 Flupyrazofos의 잔류량은 낮은편이며 시간이 경과할 수록 현저히 감소했다. 반감기는 사양토의 경우 20일, 식양토는 18일이었다. 심토로 이동${\cdot}$잔류된 농도는 매우 낮았다. 6. Flupyrazofos의 흡착시험, 용탈시험, 포장시험 결과와 약제의 물리화학적 특성을 근거로 판단할 때 공시농약은 토양에서 잘 흡착되고 이동${\cdot}$잔류성이 낮기 때문에, 상용농도를 시용할 경우 주변 환경에 미칠 수 있는 위해성은 낮은 것으로 판단된다.

  • PDF

옹이 형태별 소재의 압축강도 예측에 관한 연구 (A Study on the Estimation for the Compressive Strength of Member According to the Knot Types)

  • 김광철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권3호
    • /
    • pp.170-177
    • /
    • 2010
  • 구조용 목재부재의 성능 예측에 가장 큰 영향을 끼치는 옹이를 활용하여 유한요소 수치해석을 실시하였다. 다른 구조용 재료와 달리 목재의 경우 직교이방성을 나타내기 때문에 이를 적용하였고 옹이를 실린더 형태, 원추형 형태, 육면체 형태로 모델화 하였다. 목재 부재에 대해 실제 압축강도실험을 실시하여 그 파괴형태를 파악하고 최대강도값을 계산하였으며, 각 부재의 치수와 옹이의 크기, 위치, 개수를 반영한 수치해석 모델을 제작하여 유한요소해석을 실시하였다. 실험에서 얻어진 최대압축강도를 적용한 수치해석을 실시하여 옹이자료에 따른 각 부재의 응력분포형태를 파악하고 이를 실제 부재의 파괴형태와 비교 분석하였다. 수치해석에 소요되는 시간이나 요수 분할의 어려움, 옹이 주위의 응력 전달의 유사성 등에 기준했을 때 실린더 형태의 요소가 가장 타당하다고 판단되었다. 또한 응력 분포 모양과 변형 분포 모양을 비교한 경우 유한 요소 수치해석의 결과에서 응력이 가장 집중되는 부분과 변형이 가장 심하게 발생한 주위에서 실제 시편의 파괴나 균열이 발생함을 알 수 있었다. 이를 기초로 유한요소 수치해석법을 직교이방성과 옹이 모델링을 적절히 적용할 경우 휨응력을 받는 부재와 인장 응력을 받는 부재 등의 성능 해석에 유용한 수단으로 활용될 수 있을 것으로 판단된다.

제주도 초지피복 기생화산("오름")의 방위별 일 최고기온 분포 (Azimuthal Distribution of Daily Maximum Temperatures Observed at Sideslopes of a Grass-covered Inactive Parasitic Volcano ("Ohreum") in Jeju Island)

  • 서희철;전승종;윤진일
    • 한국농림기상학회지
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2008
  • 초지피복 조건에서 사면의 일사수광량 차이가 일 최고기온에 미치는 영향을 파악하기 위해 2007년 하지부터 동지까지 밑면지름 570m, 높이 90m인 원추형 기생화산 "높은오름"의 측면 경사 8 지점에서 일 최고기온을 측정하였다. 8개 지점 평균값을 기준온도로하여 각 지점의 기온편차를 구해 비교한 결과 기온편차는 하지로부터 동지로 갈수록 커지는 경향이었고, 관측기간 평균은 남향사면에서 $1.0^{\circ}C$, 북향사면에서 $-0.8^{\circ}C$로서 그 차이가 평균 $1.8^{\circ}C$에 달했다. 기온편차의 월별 평균은 11월에 가장 크며 남향사면에서 $2.1^{\circ}C$, 북향사면에서 $-1.3^{\circ}C$였다. 일별 기온편차의 최대값은 남향사면에서 $3.8^{\circ}C$, 북향사면에서 $-2.7^{\circ}C$에 달했는데, 이러한 기온편차 변이는 일사수광량 편차에 근거한 지형특성지수와 높은 상관을 보여 복잡지형의 일 최고기온 추정모형 개발에 활용될 수 있을 것으로 기대된다.

아음속 및 초음속 유동의 플러시 대기자료 측정장치 연구 (Study of the Flush Air Data Sensing System for Subsonic and Supersonic Flows)

  • 이창호
    • 한국항공우주학회지
    • /
    • 제47권12호
    • /
    • pp.831-840
    • /
    • 2019
  • 플러시 대기자료 측정장치는 비행체 표면에서 측정되는 압력 데이터를 이용하여 대기자료를 예측한다. FADS는 돌출된 프로브가 없으므로 고성능 항공기, 스텔스 비행체 및 극초음속 비행체에 적합하다. 본 논문에서는 구-원추 형상을 갖는 비행체에 대해서 아음속부터 초음속 비행까지 대기자료를 예측할 수 있는 FADS의 교정 절차와 계산 알고리즘을 제시한다. 표면 압력 데이터 측정을 위해 노즈부 표면에 5개 플러시 압력공들을 마련하였다. 유동각 예측과 압력 관련 변수의 예측을 분리하는 개념이며, 아음속 유동의 포텐셜 유동해와 극초음속 유동의 수정 뉴톤식을 결합한 압력모델을 사용한다. 교정 압력 데이터는 Euler 방정식을 푸는 전산유체역학 코드를 만들어서 마흐수 0.5 ~ 3.0의 범위에서 구축하였다. 비행 마흐 수 0.6~3.0, 받음각과 옆미끄럼각은 각각 -10° ~ +10°의 범위에서 여러 비행조건에 대해서 테스트를 수행하였다. 예측된 대기자료는 받음각, 옆미끄럼각, 마흐수, 자유류 정압이며 참고 데이터와 비교하여 정확도를 분석하였다.

측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향 (INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE)

  • 민경산;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

선회류를 이용한 응집침전모듈의 개발 및 실증 연구 (Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone)

  • 문진영;조영근;송승준;김진한
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3336-3344
    • /
    • 2014
  • 본 연구의 목적은 소규모 응집침전모듈의 개발 및 lab-scale 테스트를 통한 실증이다. 최근 하수처리율이 높아짐에 따라 비점오염원 관리에 대한 관심이 높아지고 있어 소규모 처리장치 개발의 필요성이 증대되고 있다. 본 연구의 응집침전모듈은 응집공정 이후 외부 영역에서 선회류를 통한 플럭(floc)의 추가 성장 및 미세 플럭 수의 감소, 내부 침전 영역에서 수직 수평류 복합침전방식을 통한 침전효율 증대로 효과적인 고액분리가 가능토록 하였다. 응집침전모듈은 수직 수평류 복합침전 방식을 통해 재래식침전조에 비해 같은 체적에서 침전면적 및 표면부하율을 4.4배 증가시킬 수 있었다. 본 연구에서 외부 및 내부 침전 영역에서의 선회류 형성 유지와 내부 침전영역에서의 균등한 유량분배를 본 공정의 중요한 설계인자로 선정하였고, 이의 도출을 위해 유체유동해석 모델인 FLUENT를 이용하였다. 선회류 유동경향 모사를 통해 유입속도, 외부조의 규격, 하부콘호퍼 깊이 등을 결정하였고 속도분포 및 유량분배 해석을 통해 유출공 직경과 개수, 유출홀 직경 등 내부 침전영역의 세부 규격을 도출하였다. $60{\ell}/hr$규모의 파일럿 테스트 결과 20분의 체류시간 동안(표면부하율은 $37.3m^3/m^2$일)탁도 300~800 NTU의 폐수를 고분자응집제 주입 없이 10 NTU 이하로 처리할 수 있었으며, 유체유동해석 모델을 활용한 설계인자 도출의 가능성을 확인하였다.

다양한 형상의 우주 물체와 충돌 각도를 고려한 우주 구조물의 초고속 충돌 시뮬레이션 연구 (Hypervelocity Impact Simulations Considering Space Objects With Various Shapes and Impact Angles)

  • 신현철;박재상
    • 한국항공우주학회지
    • /
    • 제50권12호
    • /
    • pp.829-838
    • /
    • 2022
  • 본 연구에서는 다양한 형상의 우주 물체와 우주 구조물 사이의 충돌 각도를 고려한 초고속 충돌(Hypervelocity impact) 시뮬레이션 연구를 수행하였다. 비선형 구조 동역학 전산 해석 프로그램인 LS-DYNA의 완화 입자 유동법(Smoothed Particle Hydrodynamics, SPH)을 사용하여 초고속 충돌 현상을 묘사하였으며, 금속 재료의 비선형 거동을 구현하기 위하여 Mie-Grüneisen의 상태 방정식과 Johnson-Cook의 재료 모델을 사용하였다. 구, 정육면체, 원기둥 및 원뿔 형상의 다양한 형상의 우주 물체를 이용하였으며, 우주 구조물은 알루미늄 평판(200 mm×200 mm×2 mm)으로 모델링되었다. 우주 물체가 우주 구조물 대비 4.119 km/s의 상대 속도로 충돌하는 시뮬레이션을 수행하여 동일 질량을 갖는 다양한 형상의 우주 물체와 우주 구조물 사이의 0°, 30° 및 45°의 충돌 각도를 고려하였을 시 초고속 충돌에 의하여 발생되는 파편운(debris cloud) 형상을 분석하였다. 동일한 운동 에너지를 갖는 우주 물체는 형상의 차이로 인해 모두 다른 파편운이 형성되었다. 더불어 충돌 각도의 증가에 따라 파편운의 크기가 줄어드는 경향을 확인하였다.

GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구 (Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System)

  • 이충일;신재원;신헌주;정재용;김연래;민정환;홍승우;정수미;정원균;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.192-200
    • /
    • 2010
  • 사이버나이프 치료에서 사용하는 소조사면은 전자평형의 부재와 급격한 선량 경사도(Steep dose gradients), 그리고 광자와 전자들의 스펙트럼 변화 요인으로 인하여 소조사면 광자선 선량 측정은 일반적인 치료의 측정보다 좀더 어렵고 복잡하다. 본 연구에서는 다이오드 검출기를 이용한 측정값과 GEANT4를 이용한 계산값을 비교하고 정확한 선량 전달을 위한 측정 선량의 검증 도구의 한 종류로 GEANT4의 유용성을 입증하고자 한다. 사이버나이프 몬테카를로 모델을 개발하는데 있어 두 단계로 진행하였다. 첫 번째 단계는 선형가속기 헤드(treatment head) 시뮬레이션과 이를 통한 광자 에너지 스펙트럼의 계산이었고, 두 번째 단계는 5, 10, 20, 30, 50, 60 mm의 여섯 개 원형 조사면에 대한 물팬텀속에서의 깊이선량율의 계산이었다. 그리고 출력인수(Relative output factors)에 대한 계산은 5 mm부터 60 mm까지 총 12가지 조사면에 대해 수행되었으며 그 결과를 다이오드 검출기를 이용한 측정값과 비교하였다. 가로선량분포(Profiles)의 경우 5, 10, 20, 30, 50, 60 mm의 6가지 조사면에 대해 계산이 이루어졌고 깊이는 1.5, 10, 20 cm의 세 가지 깊이에 대해 수행되었다. 깊이선량율의 계산값을 측정값과 비교한 결과 평균 2% 미만의 오차를 보여 임상에서 허용 가능한 결과를 얻었다. 조사면 출력인자의 경우에 조사면 직경 7.5 mm 이상에서 3% 이내의 오차를 보였으나 직경 5 mm 조사면에서는 6.9%로 높은 오차를 보였다. 가로선량분포에서 20 mm 이상의 조사면에서는 2% 미만의 오차를 보였고 그 이하의 조사면에서는 3.5% 미만의 오차를 보였다. 본 연구에서는 소조사면 사이버나이프 측정을 위한 선량분포 계산을 GEANT4 코드를 사용하여 다이오드 측정 결과와 비교하였다. 다이오드와의 측정 비교 결과 5 mm 조사면을 제외한 나머지 조사면들에 대해 오차 0.2~0.6% 내의 만족할만한 결과를 얻었다. 향후 소조사면에서 정확성을 가지는 Gafchromic 필름 등 다른 측정기와 비교를 통하여 그 정확성이 평가된다면 이 GEANT4의 선량분포 계산 방법은 소조사면을 이용하는 사이버나이프 방사선치료에서 정확한 선량 전달을 위한 측정 선량의 검증 도구의 한 종류로 사용할 수 있을 것으로 예상한다.

제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드 (Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides)

  • 권창렬;최병호;정승미;주상돈
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.271-278
    • /
    • 2012
  • 연구 목적: 최근 정확하면서도 외상이 적은 임플란트 식립을 위해 임플란트 수술용 가이드가 많이 쓰이고 있다. 그 중 대표적인 방식이 stereolithography 방식과 positioning device로 제작한 방식이다. 본 연구는 이 두 가지 방식의 정확성을 비교하기 위하여 4 가지 형태의 치아상실 모델에서 실험 후 정확성에 관하여 분석하였다. 연구 재료 및 방법: 4가지 형태 치아 결손 모델 각각에 대하여 stereolithography 방법과 positioning device를 이용한 방법으로 수술 가이드를 제작하였다. 제작된 수술 가이드를 제작에 사용되었던 치아모델에 장착하여 수술 가이드의 내면과 모델의 치아표면 사이 공간크기를 측정하여 가이드의 적합도를 평가하였다. 또한 이 수술 가이드를 이용하여 총 40개 모델에서 임플란트 시술을 진행하고, 시술 후 모델을 다시 cone-beam computed tomography촬영 하여 수술 전후 영상을 중첩시켜 계획 상의 임플란트와 실제 시술한 임플란트의 위치를 비교하였다. 통계학적인 검증을 위하여 PASW Statistics$^{(R)}$ 18.0을 이용하여서 Mann-Whitney U 검정을 사용하였다. 결과: 수술 가이드 내면과 모델 사이 공간크기가 stereolithography는 $1.4{\pm}0.3mm$이고, positioning device는 $0.4{\pm}0.3mm$로 통계학적으로 유의한 차이를 보였다(P<.05). Stereolithography는 오차가 근원심 측에서 $3.9{\pm}1.6^{\circ}$, 협설 측에서 $2.7{\pm}1.5^{\circ}$, 깊이에서 $1.9{\pm}0.9mm$였다. 반면 positioning device는 오차가 근원심 측에서 $0.7{\pm}0.3^{\circ}$였고, 협설측에서 $0.3{\pm}0.2^{\circ}$, 깊이에서 $0.4{\pm}0.2mm$였다. 두 수술 가이드 제작방법은 모든 방향에서의 오차에서 통계학적으로 유의한 차이를 보였다(P<.05). 결론: 본 연구의 결과는stereolithography방법보다 positioning device를 이용하여 수술 가이드를 제작할 때 C.T.와 임플란트 치료 계획 프로그램을 이용하여 미리 계획한 임플란트 식립 위치와 방향으로 더 정확하게 식립 할 수 있음을 보여 주었다.